Fans running at a higher than expected speed

Symptom

The fans are running at a higher speed than expected.

Cause

Action

  1. Update the server to the latest firmware versions, such as iLO firmware, system BIOS, option firmware, etc.
  2. Verify the Temperature tab. Fan speeds can be high if a sensor temperature is within approximately 10°C of the Caution threshold.
  3. Verify that all air baffles and required blanks, such as drive blanks, processor heatsink blanks, power supply blanks, etc., are installed.
  4. Verify that the correct processor heatsink is installed.
  5. Verify that the correct fan is installed, if the system supports both standard fans and performance fans.

For more information about updating the firmware, see "Updating firmware or System ROM." For server-specific documentation, see "Server documentation."