Add or edit a power delivery device
Add or edit an iPDU power delivery device
The following table describes power delivery device configuration characteristics. To add or edit the properties of a non-iPDU device, see Add or edit a non-iPDU power delivery device.
Screen Component |
Description |
---|---|
Type | The type of power device, do not change from the default value to add an iPDU.
|
IP address or hostname | The fully qualified name, IPv4 address, or IPv6 address of the power delivery device
|
User name | Name of a user with the appropriate authorization settings to access the iPDU |
Password | Password for the user with access to the iPDU |
Name | The user-defined name assigned to the power delivery device.
|
Power Connections | This section displays the details of the power connections to the power delivery device. Use this section to add and remove power connections. |
Name | The name of the device that is connected to the power delivery device The device name is a hyperlink to an overview of the device on the corresponding screen for the device type. |
Model | The model name of the device connected to the power delivery device |
Connection | The name of the device that provides the connection to the power delivery device Connection is blank if no connection is specified or if the device is a power delivery device If the connection is to an HPE AC Module, the connection is the name its enclosure, which is a hyperlink to the overview of the enclosure on the Enclosures screen. |
Remove | Click the X to remove the device in that row from the power connections to the power delivery device |
Add connections button | Opens the Add connections dialog box |
Buttons | See Button functions for information about how buttons operate. |
Add or edit a non-iPDU power delivery device
The following table describes power delivery device configuration characteristics. To add or edit the properties of an iPDU device, see Add or edit an iPDU power delivery device.
See Power delivery device types for a list of device types.
Screen Component |
Description |
---|---|
Type | Select the type of power delivery device. |
Name | Enter the name of the power delivery device.
|
Model | The model name of the power delivery device |
Rated capacity | The rated capacity for the power delivery device, in amperes (A) |
Line voltage | The input line voltage for the power delivery device, in volts (V) Select the phase of the line voltage. Choose from
|
Power feed | The device power feed side setting:
|
Part number | The part number of the power delivery device (optional)
|
Serial number | The serial number of the power delivery device (optional)
|
Power Connections | This section displays the details of the power connections to the power delivery device. Use this section to add and remove power connections. |
Remove | Click the X to remove the device in that row from the power connections to the power delivery device |
Add connections button | Click the Add connections button to open the Add connections dialog box. |
Remove all button | Click the Remove all button to remove all power connections from the power delivery device |
Buttons | See Button functions for information about how buttons operate. |