You can create custom utilization graphs by selecting two metrics for a particular resource. The two metrics you select are displayed on a single graph. The custom metrics that are available depend on the resource you are viewing.
Only for interconnects, the CPU utilization metrics show a graph trend for last five minutes utilization.
The other attributes such as temperature, power, and memory display the present or current value.
See
Create a custom utilization graph to learn more.
Resource
|
Metrics
|
Enclosures |
- Average power
The average power consumption of the enclosure over the time interval, in watts
- Peak power
The peak power consumption of the enclosure over the time interval, in watts
- Power cap
The power cap for the enclosure, in watts; displayed as a gray band across the graph
- Derated capacity
The limit of the average power consumption, in watts, of the enclosure. Displayed as a gray band on the graph
- Rated capacity
The limit of the peak power consumption, in watts, of the enclosure. Displayed as a gray band on the graph
- Temperature
The temperature of the enclosure over the time interval in Celsius or Fahrenheit (depending on your browser locale settings)
|
Server Hardware |
- CPU utilization
The percentage of CPU utilization by the device over the time interval
- CPU speed
The speed of the device CPU over the time interval, in GHz
- Average power
The average power consumption of the device over the time interval, in watts
- Peak power
The peak power consumption of the device over the time period, in watts
- Power cap
The user-defined power cap, displayed as a gray band that covers the values the cap restricts
- Temperature
The temperature of the device over the time interval, in degrees Celsius or Fahrenheit (depending on your browser locale settings)
|