Defining Image Streamer uplink sets in logical interconnect groups — single frame configuration
When you add or edit an Image Streamer uplink set to support connections to Image Streamer in a single frame configuration, you designate the following attributes:
A name
Type — Ethernet
NOTE:If HPE Virtual Connect SE 100Gb F32 Module for HPE Synergy interconnect is used in single-frame, type can be set to Image Streamer.
The Image Streamer deployment network
One uplink port
- The top port selector is filtered to only include only ports from the A-side interconnect module.
For Frame Link Modules in the same HPE Synergy 12000 Frame with the Image Streamer, you must connect MGMT port 2 to the A-side interconnect. The following table illustrates this cross-connection when using the HPE QSFP+ to SFP+ adapter and HPE 10G base T SFP+ Transceiver.
Enclosure |
MGMT port |
Interconnect |
Uplink port for HPE VC SE 40Gb F8 Module |
Uplink port for HPE VC SE 100Gb F32 Module |
---|---|---|---|---|
A |
1 |
– |
– |
– |
A |
2 |
A |
Q{x}.1 |
X1 |
When creating a logical interconnect group with an uplink set for Image Streamer in a single frame configuration, Hewlett Packard Enterprise strongly recommends setting the Redundancy mode as follows:
Non-redundant (A side only) — If only an A-side master interconnect module is present.
Redundant — If A-side and B-side master interconnect modules are present.
In both multi- and single frame configurations, you cannot delete an Image Streamer uplink set from a logical interconnect group if the logical interconnect group is associated with an enclosure group that has OS deployment configured.