Monitored enclosures
Enclosures with HPE ProLiant G6 server blades
HPE Integrity Superdome X enclosures
If the firmware for any part of an
HPE BladeSystem c7000 Enclosure does not meet the supported minimum, the enclosure will be added in an
Unmanaged
state. To resolve this issue, update the firmware manually (outside of
HPE OneView) and then refresh the enclosure.
If the HPE BladeSystem Onboard Administrator firmware for an HPE Integrity Superdome X enclosure does not meet the supported minimum, the add enclosure fails. To resolve this issue, update the firmware manually (outside of HPE OneView) and then re-add the enclosure for monitoring.
Move an HPE BladeSystem c7000 Enclosure enclosure from monitored to managed
Once an enclosure is monitored in
HPE OneView, if you decide to change from
monitored
to
managed
, you must remove the enclosure from
HPE OneView and then migrate or add it back as a managed enclosure, obtaining the appropriate license. Migration keeps the configuration settings, whereas add does not migrate the configuration.