Target port failure in HPE OneView
Target port is in a failure state.
Solution 1Cause
Action
Target port failure is that the Actual and Expected network are mismatched. The expected network needs to be updated on the appliance.
Solution 2Cause
Action
The physical cabling is improperly configured (Fabric attach).
Verify that the cabling between the storage system and the SAN switch is properly configured.
Solution 3Cause
Action
Port failed on device.
Examine your storage system hardware. Repair as necessary.
For more information about the hardware, see https://www.hpe.com/info/oneview/docs.
Solution 4Cause
Action
The enclosure that is physically connected to the storage system has not been added to the appliance (Direct attach).
Use the
Enclosures screen to add the enclosure to the appliance.
Solution 5Cause
Action
The physical cabling is improperly configured (Direct attach).
Verify that the cabling between the storage system and the enclosure interconnects is properly configured.
.