Systems Insight Display combined LED descriptions

The combined illumination of the following LEDs indicates a system condition:

  • Systems Insight Display LEDs
  • System power LED
  • Health LED
Systems Insight Display LED and color Health LED System power LED Status
Processor (amber) Red Amber

One or more of the following conditions might exist:

  • Processor in socket X has failed.
  • Processor X is not installed in the socket.
  • Processor X is unsupported.
  • ROM detects a failed processor during POST.
Processor (amber) Amber Green Processor in socket X is in a pre-failure condition.
DIMM (amber) Red Green One or more DIMMs have failed.
DIMM (amber) Amber Green DIMM in slot X is in a pre-failure condition.
Over temp (amber) Amber Green The Health Driver has detected a cautionary temperature level.
Over temp (amber) Red Amber The server has detected a hardware critical temperature level.
PCI riser (amber) Red Green The PCI riser cage is not seated properly.
Fan (amber) Amber Green One fan has failed or has been removed.
Fan (amber) Red Green Two or more fans have failed or been removed.
Power supply (amber) Red Amber

One or more of the following conditions might exist:

  • Only one power supply is installed and that power supply is in standby.
  • Power supply fault.
  • System board fault.
Power supply (amber) Amber Green

One or more of the following conditions might exist:

  • Redundant power supply is installed and only one power supply is functional.
  • AC power cord is not plugged into redundant power supply.
  • Redundant power supply fault.
  • Power supply mismatch at POST or power supply mismatch through hot-plug addition.
Power cap (off) Amber Standby.
Power cap (green) Flashing green Waiting for power.
Power cap (green) Green Power is available.
Power cap (flashing amber) Amber Power is not available.
IMPORTANT: If more than one DIMM slot LED is illuminated, further troubleshooting is required. Test each bank of DIMMs by removing all other DIMMs. Isolate the failed DIMM by replacing each DIMM in a bank with a known working DIMM.