Systems Insight Display power switch module option

This option is not supported in servers configured with 4LFF or 12LFF drives.

To install the component:

Procedure
  1. Power down the server.
  2. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  3. Do one of the following:
  4. Remove the access panel.
  5. Remove the air baffle.
  6. Remove the fan cage.
    CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinched or crimped.
  7. Remove the cabled power switch module. Retain the T-10 screw for later use.
    Removing the UID
  8. Route the cable through the opening in the front of the server, and then install the SID power switch module. Secure the module using the existing screw.
    Installing the SID module
  9. Connect the SID module cable to the system board power switch module connector.
    Connecting the SID cable
  10. Install the fan cage.
  11. Install the air baffle.
  12. Install the access panel.
  13. Slide the server into the rack.
  14. Connect each power cord to the server.
  15. Connect each power cord to the power source.
  16. Power up the server.