High-performance fan option

To install the component:

Procedure
  1. Power down the server.
  2. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  3. Do one of the following:
  4. Remove the access panel.
    IMPORTANT: Do not mix standard fans and high-performance fans in the same server.
  5. Remove fan blanks and standard fans from all locations:
    • Fan blanks
      Removing fan blanks
    • Standard fans
      Removing standard fans
  6. Install high-performance fans in all locations.
    Installing high performance fans
  7. Install the access panel.
  8. Slide the server into the rack.
  9. Connect each power cord to the server.
  10. Connect each power cord to the power source.
  11. Power up the server.