CAUTION: To avoid damage to server components, fan blanks must be installed in fan bays 1 and 2 in a single-processor configuration. |
The only two valid fan configurations are listed in the following table.
Configuration |
Fan bay 1 |
Fan bay 2 |
Fan bay 3 |
Fan bay 4 |
Fan bay 5 |
Fan bay 6 |
---|---|---|---|---|---|---|
1 processor |
Fan blank |
Fan blank |
Fan |
Fan |
Fan |
Fan |
2 processors |
Fan |
Fan |
Fan |
Fan |
Fan |
Fan |
For a single-processor configuration, four fans and two blanks are required in specific fan bays for redundancy. A fan failure or missing fan causes a loss of redundancy. A second fan failure or missing fan causes an orderly shutdown of the server.
Installing more than the required number of fans in a single-processor configuration is not a supported configuration.
For a dual-processor configuration, six fans are required for redundancy. A fan failure or missing fan causes a loss of redundancy. A second fan failure or missing fan causes an orderly shutdown of the server.
The server supports variable fan speeds. The fans operate at minimum speed until a temperature change requires a fan speed increase to cool the server. The server shuts down during the following temperature-related scenarios:
CAUTION: A thermal event can damage server components when the Thermal Shutdown feature is disabled in RBSU. |