Primary 3-slot PCI riser cage

WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove the power cord to remove power from the server. Pressing the Power On/Standby button does not shut off system power completely. Portions of the power supply and some internal circuitry remain active until AC power is removed.

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all PCI slots have either an expansion slot cover or an expansion board installed.

To install the component:

  1. Power down the server.
  2. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  3. Extend the server from the rack.
  4. Remove the access panel.
  5. Remove any expansion board installed in the slot.
  6. Remove the riser cage.

    Removing the standard PCI riser

To replace the component, reverse the removal procedure.