Installing the ATX 550W non-hot-plug power supply

Prerequisites

Before you perform this procedure, make sure that you have the following items available:

  • ATX 550W non-hot-plug power supply

  • T-15 Torx screwdriver

Procedure
  1. Power down the server.
  2. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  3. Disconnect all peripheral cables from the server.
  4. Do one of the following:
  5. Remove the access panel.
  6. Remove the PCI air baffle.
  7. Remove the system air baffle.
  8. Disconnect all the power supply cables connected to the system board.
  9. Remove the existing power supply.

    Removing the existing power supply
  10. Install the ATX 550W non-hot-plug power supply.

    Installing the non-hot-plug power supply
  11. Connect the power supply cables.
  12. Install the system air baffle.
  13. Install the PCI air baffle.
  14. Install the access panel.
  15. Do one of the following:
  16. Connect all peripheral cables to the server.
  17. Connect each power cord to the server.
  18. Connect each power cord to the power source.
  19. Power up the server.

The installation is complete.