Installing an internal USB device

Procedure
  1. Power down the server.
  2. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  3. Disconnect all peripheral cables from the server.
  4. Do one of the following:
  5. Remove the access panel.
  6. Remove the PCI air baffle.
  7. Remove the system air baffle.
  8. Locate the internal USB connector.
  9. Plug in the USB device into the internal USB port.

    Installing the internal USB device
  10. Install the system air baffle.
  11. Install the PCI air baffle.
  12. Install the access panel.
  13. Do one of the following:
  14. Connect all peripheral cables to the server.
  15. Connect each power cord to the server.
  16. Connect each power cord to the power source.
  17. Power up the server.

The installation is complete.