Installing the four-bay LFF non-hot-plug drive cage

Prerequisites

Before you perform this procedure, make sure that you have the following items available:

  • Four-bay LFF non-hot-plug drive cage option

  • LFF non-hot-plug drive option

  • T-15 Torx Screwdriver

Procedure
  1. Power down the server.
  2. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  3. Disconnect all peripheral cables from the server.
  4. Do one of the following:
  5. Remove the access panel.
  6. Remove the front bezel.
  7. Remove the PCI air baffle.
  8. Remove the system air baffle.
  9. Remove the drive bay cover from box 2.

    Removing the drive bay cover from box 2
  10. Install the non-hot-plug drives.
  11. Install the drive cage in box 2.

    Installing the non-hot-plug drive cage
  12. Connect the drive cables.
  13. Install the system air baffle.
  14. Install the PCI air baffle.
  15. Install the front bezel.
  16. Install the access panel.
  17. Do one of the following:
  18. Connect all peripheral cables to the server.
  19. Connect each power cord to the server.
  20. Connect each power cord to the power source.
  21. Power up the server.

The installation is complete.