Installing an energy pack

Prerequisites
Procedure
  1. Back up all server data.
  2. Power down the server.
  3. Remove all power:
    1. Disconnect each power cord from the power source.
    2. Disconnect each power cord from the server.
  4. Disconnect all peripheral cables from the server.
  5. Do one of the following:
  6. Remove the access panel.
  7. Remove the PCI air baffle.
  8. Remove the system air baffle.
  9. Remove the energy pack holder slot covers.

    Removing the energy pack holder slot covers
  10. Install the energy pack holder.

    Installing the energy pack holder
  11. Install the energy pack:
    1. Install the energy pack into the holder.
    2. Route the energy pack cable through the cable clip and connect to the system board.

    Installing the energy pack
  12. Connect the storage controller backup power cable.
  13. Install the system air baffle.
  14. Install the PCI air baffle.
  15. Install the access panel.
  16. Do one of the following:
  17. Connect all peripheral cables to the server.
  18. Connect each power cord to the server.
  19. Connect each power cord to the power source.
  20. Power up the server.

The installation is complete.