Fan cage implementation

The fan cage is required to meet the system thermal requirements for the following configurations:
  • Server operating in rack mode

  • Dual-processor configuration

  • Server with the following drive box configurations:

    • The maximum number of drives is installed in boxes 1, 2, and 3 (12 drives for LFF configuration, 24 drives for SFF configuration).

    • The maximum number of drives is installed in boxes 2 and 3, and at least two media devices are installed.

  • Server with the following options installed:
    • NVMe SSDs

    • M.2 SSDs

    • SFF SAS drives with 10K or 15K rpm rate

    • Smart Array P-class 800-series Gen10 controllers*

    • GPUs*

    • HPE EDR InfiniBand adapters*

    • High-performance NIC controllers*

      For specific models covered by the options marked with an asterisk (*), see the product QuickSpecs on the server website at https://www.hpe.com/servers/ml350-gen10.

  • ASHRAE A3 and A4 compliant configurations