1786-Slot X Drive Array Recovery Needed

Symptom

1786-Slot X Drive Array Recovery Needed. The following drive(s) need Automatic Data Recovery (Rebuild): Port x Box y Bay(s) z

Select F1 to continue with recovery of data to drive. Select F2 to continue without recovery of data to drive.

Cause

A failed or replacement drive has not yet been rebuilt.

Action
  1. Do one of the following:
    • Press the F1 key to continue with recovery of data to the drive. Data will be automatically restored to the drive when a failed drive has been replaced, or to the original drive if it is working again without errors.

    • Press the F2 key to continue without recovery of data to the drive. The failed drive will not be rebuilt and the system will continue to operate in a failed state of Interim Data Recovery Mode.

  2. Replace the failed drive and press the F1 key to rebuild the array. If the drive rebuild is not successful or is aborted because the system rebooted before the rebuild of the drive completed, another version of the 1786 POST error message is displayed.