Message identifiers 24725-24749
Message Id: 24725
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that the consistency initialization pass has completed for logical drive <logical drive number>.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24726
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported an uncorrectable read error during surface analysis operations for logical drive <logical drive number>. A media error was encountered that is not correctable due to media errors on other physical drive(s) belonging to this logical volume. The uncorrectable media defects are between logical block address <lba number 1> and logical block address <lba number 2>. The host will be unable to read some blocks between this address range until the blocks are overwritten. Capacity expansion operations must be avoided while the blocks are unreadable.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24727
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that the surface analysis uncorrectable read error condition for logical drive <logical drive number> has ended. The previously reported media defects have been overwritten. Capacity expansion operations may now be conducted.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24728
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that a firmware update is needed for the physical drive with product ID <ID number>. The recommended minimum firmware revision should be <firmware revision number>.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24729
Severity: Informational
Log message: The MSA chassis labeled as <chassis label> has reported that external redundant controller <slot number> has been <inserted / removed>.
The external Smart Array controller reporting this operation is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24730
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that power supply number <power supply number> was <inserted / removed>.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id=24731
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that fan number <fan number> was <inserted / removed>.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24732
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that a SAS link PHY error has been detected. The PHY error threshold has been exceeded for PHY number <PHY number> located on expander number <expander number>.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24733
Severity: Informational
Log message: The external Smart Array controllers located in the MSA chassis labeled as <chassis label> are now redundant.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24734
Severity: Error
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> is reporting that no redundant array controller is installed.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24735
Severity: Error
Log message: The external Smart Array controllers located in the MSA chassis labeled as <chassis label> are not redundant because they are different models.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24736
Severity: Error
Log message: The external Smart Array controllers located in the MSA chassis labeled as <chassis label> are not redundant because an inter-controller link could not be established.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24737
Severity: Error
Log message: The external Smart Array controllers located in the MSA chassis labeled as <chassis label> are not redundant because the array controllers are reporting different firmware revisions.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24738
Severity: Error
Log message: The external Smart Array controllers located in the MSA chassis labeled as <chassis label> are not redundant because the array controllers are reporting different cache sizes.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24739
Severity: Error
Log message: An external Smart Array controller located in the MSA chassis labeled as <chassis label> is reporting that it is not redundant because the other external controller is reporting a cache failure.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24740
Severity: Error
Log message: The external Smart Array controllers located in the MSA chassis labeled as <chassis label> are no longer redundant because both array controllers cannot see all the physical drives.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24741
Severity: Error
Log message: The external Smart Array controllers located in the MSA chassis labeled as <chassis label> are no longer redundant because one or more drives has been determined not to be able to support redundant controller operations.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24742
Severity: Error
Log message: The external Smart Array controllers located in the MSA chassis labeled as <chassis label> are no longer redundant because an expand operation is in progress. The controllers will become redundant once again once the expand operation has completed.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24743
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that a SAS link error has been detected between port <port number> of the external controller and I/O module number <module number> of box number <box number>. Please check this data path and the associated hardware.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24744
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that a SAS link error has been detected between port <port number> and <attached device><attached device index>. Please check this data path and the associated hardware.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24745
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that a SAS link error has been detected from its onboard expander. Please check this controller to ensure it is functioning properly.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24746
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that a SAS link error has been detected between its onboard expander and an externally connected storage box. This error has been detected between port <port number> of the external controller and I/O module number <module number> located in box number <box number>. Please check this data path and the associated hardware.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24747
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that a SAS link error has been detected between its onboard expander (port <port number>) and <attached device><attached device index>. Please check this data path and the associated hardware.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24748
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that a SAS link error has been detected between I/O module <module number 1> of box <box number 1> and I/O module <module number 2> of box <box number 2>. These boxes are connected to port <port number> of the external array controller. Please check this data path and the associated hardware.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.
Message Id: 24749
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that a SAS link error has been detected in bay <bay number> of box <box number> which is connected to port <port number> of the external array controller. Please check this data path and the associated hardware.
The external Smart Array controller reporting this event is attached to the host side Smart Array controller <controller name / slot information>.