1804-Slot X Drive Array – Cache Module critical error

Symptom

1804-Slot X Drive Array – Cache Module critical error. Action: Replace Cache Module (Controller is disabled until this problem is resolved).

Cause

The cache module has failed.

Action
Replace the cache module. For more information, see the server maintenance and service guide on the Hewlett Packard Enterprise website.