Event Identifiers 1103-1183

NT Event ID: 1103 (Hex)0x8435044f (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Fault Tolerant Power Sub-system has been set to Degraded. Check power connections and replace the power supply as needed.

SNMP Trap: cpqHe3FltTolPwrSupplyDegraded - 6028 in CPQHLTH.MIB

Symptom: The fault tolerant power supply sub-system condition has been set to degraded.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “The server power supply status has become degraded.”

NT Event ID: 1108 (Hex)0x84350454 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Remote Insight Board has detected unauthorized login attempts. More than '%4'

login attempts detected.

SNMP Trap: cpqSm2UnauthorizedLoginAttempts - 9003 in CPQSM2.MIB

Symptom: Remote Insight/Integrated Lights-Out Unauthorized Login Attempts. The Remote Insight/Integrated Lights-Out firmware has detected unauthorized login attempts.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSm2CntlrBadLoginAttemptsThresh

Supporting SNMP Trap Description: “More than [cpqSm2CntlrBadLoginAttemptsThresh] unauthorized login attempts detected.”

NT Event ID: 1109 (Hex)0xc4350455 (cpqsvmsg.dll)

Log Severity: Error (3)

Log Message: The Remote Insight Board has detected a battery failure.

SNMP Trap: cpqSm2BatteryFailed - 9004 in CPQSM2.MIB

Symptom: Remote Insight Battery Failed. The Remote Insight battery has failed and needs to be replaced.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “Remote Insight battery failed.”

NT Event ID: 1110 (Hex)0xc4350456 (cpqsvmsg.dll)

Log Severity: Error (3)

Log Message: The Remote Insight Board has detected self test error '%4'.

SNMP Trap: cpqSm2SelfTestError - 9005 in CPQSM2.MIB

Symptom: Remote Insight/Integrated Lights-Out Self Test Error. The Remote Insight/Integrated Lights-Out firmware has detected a Remote Insight self test error.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSm2CntlrSelfTestErrors

Supporting SNMP Trap Description: “Remote Insight/Integrated Lights-Out self test error [cpqSm2CntlrSelfTestErrors].”

NT Event ID: 1111 (Hex)0xc4350457 (cpqsvmsg.dll)

Log Severity: Error (3)

Log Message: The Remote Insight Board has detected a controller interface error.

SNMP Trap: cpqSm2InterfaceError - 9006 in CPQSM2.MIB

Symptom: Remote Insight/Integrated Lights-Out Interface Error. The host OS has detected an error in the Remote Insight/ Integrated Lights-Out interface. The firmware is not responding.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “Server [sysName], Remote Insight/Integrated Lights-Out interface error.”

NT Event ID: 1112 (Hex)0x84350458 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Remote Insight Board has detected that the battery is disconnected.

SNMP Trap: cpqSm2BatteryDisconnected - 9007 in CPQSM2.MIB

Symptom: Remote Insight Battery Disconnected. The Remote Insight battery cable has been disconnected.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “Remote Insight battery disconnected.”

NT Event ID: 1113 (Hex)0x84350459 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Remote Insight Board has detected that the keyboard cable is disconnected.

SNMP Trap: cpqSm2KeyboardCableDisconnected - 9008 in CPQSM2.MIB

Symptom: Keyboard Cable Disconnected. The Remote Insight keyboard cable has been disconnected.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “Remote Insight keyboard cable disconnected.”

NT Event ID: 1114 (Hex)0x8435045a (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: A processor has crossed the threshold of allowable corrected errors. The processor should be replaced.

SNMP Trap: cpqSeCpuThresholdPassed - 1005 in CPQSTDEQ.MIB

Symptom: This trap is sent when an internal processor error threshold has been passed on a particular processor, causing it to become degraded. This trap is sent when cpqSeCpuThreshPassed transitions from false to true.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSeCpuSlot
  • cpqSeCpuSocketNumber
  • cpqSeCpuSpeed
  • cpqSeCpuExtSpeed
  • cpqSeCpuCacheSize

Supporting SNMP Trap Description: “CPU internal corrected errors have passed a set threshold.”

SNMP Trap: cpqSeCpuStatusChange - 1006 in CPQSTDEQ.MIB

Symptom: This trap is sent when CPU status changed. CPU can be brought down to Stop state and removed from O.S Active set or Brought back to Running state and made member of O.S Active set.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSeCpuUnitIndex
  • cpqSeCpuSlot
  • cpqSeCpuName
  • cpqSeCpuSpeed
  • cpqSeCpuStep
  • cpqSeCpuStatus
  • cpqSeCpuExtSpeed
  • cpqSeCpuSocketNumber
  • cpqSeCpuHwLocation

Supporting SNMP Trap Description: “Processor in Slot [cpqSeCpuSlot] status change to [cpqSeCpuStatus].”

SNMP Trap: cpqSeCpuPowerPodstatusChange - 1007 in CPQSTDEQ.MIB

Symptom: This Trap is sent if CPU Power Pod status changes.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSeCpuUnitIndex
  • cpqSeCpuSlot
  • cpqSeCpuName
  • cpqSeCpuSpeed
  • cpqSeCpuStep
  • cpqSeCpuPowerpodStatus
  • cpqSeCpuExtSpeed
  • cpqSeCpuSocketNumber
  • cpqSeCpuHwLocation

Supporting SNMP Trap Description: “Processor in Slot [cpqSeCpuSlot] Power supply status is [cpqSeCpuPowerpodStatus].”

NT Event ID: 1115 (Hex)0x8435045b (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: A computer cover has been removed since last system start up. Be sure the system cover is installed properly. This situation may result in improper cooling of the system due to air flow changes caused by the missing cover.

SNMP Trap: cpqSiHoodRemoved - 2001 in CPQSINFO.MIB

Symptom: The access panel is removed. The access panel status has been set to removed. The access panel is not installed properly. This situation may result in improper cooling of the system due to air flow changes caused by the missing access panel.

User Action: Replace the access panel and be sure that it is installed properly. Verify that the system is working properly.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “Hood is removed from unit.”

NT Event ID: 1116 (Hex)0x8435045c (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Remote Insight Board has detected that the mouse cable is disconnected.

SNMP Trap: cpqSm2MouseCableDisconnected - 9009 in CPQSM2.MIB

Symptom: Mouse Cable Disconnected. The Remote Insight mouse cable has been disconnected.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “Remote Insight mouse cable disconnected.”

NT Event ID: 1117 (Hex)0x8435045d (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Remote Insight Board has detected that the external power cable is disconnected.

SNMP Trap: cpqSm2ExternalPowerCableDisconnected - 9010 in CPQSM2.MIB

Symptom: External Power Cable Disconnected. The Remote Insight external power cable has been disconnected.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “Remote Insight external power cable disconnected.”

NT Event ID: 1118 (Hex)0x4435045e (cpqsvmsg.dll)

Log Severity: Information (1)

Log Message: The Fault Tolerant Power Supply Sub-system has been returned to the OK state.

SNMP Trap: cpqHe4FltTolPowerSupplyOk - 6048 in CPQHLTH.MIB

Symptom: The fault tolerant power supply condition has been set back to the OK state for the specified chassis and bay location.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeFltTolPowerSupplyChassis
  • cpqHeFltTolPowerSupplyBay
  • cpqHeFltTolPowerSupplyStatus
  • cpqHeFltTolPowerSupplyModel
  • cpqHeFltTolPowerSupplySerialNumber
  • cpqHeFltTolPowerSupplyAutoRev
  • cpqHeFltTolPowerSupplyFirmwareRev
  • cpqHeFltTolPowerSupplySparePartNum
  • cpqSiServerSystemId

Supporting SNMP Trap Description: “The Power Supply is OK on Chassis [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay], Status [cpqHeFltTolPowerSupplyStatus], Model [cpqHeFltTolPowerSupplyModel], Serial Num [cpqHeFltTolPowerSupplySerialNumber], Firmware [cpqHeFltTolPowerSupplyFirmwareRev].”

NT Event ID: 1123 (Hex)0x84350463 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: Post Errors were detected. One or more Power-On-Self-Test errors were detected during server startup.

SNMP Trap: cpqHe3PostError - 6027 in CPQHLTH.MIB

Symptom: One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “Errors occurred during server restart.”

NT Event ID: 1124 (Hex)0x84350464 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Fault Tolerant Power Supply Sub-system is in a degraded state. Restore power or replace the failed power supply.

SNMP Trap: cpqHe4FltTolPowerSupplyDegraded - 6049 in CPQHLTH.MIB

Symptom: The fault tolerant power supply condition has been set to degraded for the specified chassis and bay location.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeFltTolPowerSupplyChassis
  • cpqHeFltTolPowerSupplyBay
  • cpqHeFltTolPowerSupplyStatus
  • cpqHeFltTolPowerSupplyModel
  • cpqHeFltTolPowerSupplySerialNumber
  • cpqHeFltTolPowerSupplyAutoRev
  • cpqHeFltTolPowerSupplyFirmwareRev
  • cpqHeFltTolPowerSupplySparePartNum
  • cpqSiServerSystemId

Supporting SNMP Trap Description: “The Power Supply is Degraded on Chassis [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay], Status [cpqHeFltTolPowerSupplyStatus], Model [cpqHeFltTolPowerSupplyModel], Serial Num [cpqHeFltTolPowerSupplySerialNumber], Firmware [cpqHeFltTolPowerSupplyFirmwareRev].”

NT Event ID: 1125 (Hex)0xc4350465 (cpqsvmsg.dll)

Log Severity: Error (3)

Log Message: The Fault Tolerant Power Supply Sub-system is in a failed state. Restore power or replace the failed power supply.

SNMP Trap: cpqHe4FltTolPowerSupplyFailed - 6050 in CPQHLTH.MIB

Symptom: The fault tolerant power supply condition has been set to failed for the specified chassis and bay location.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeFltTolPowerSupplyChassis
  • cpqHeFltTolPowerSupplyBay
  • cpqHeFltTolPowerSupplyStatus
  • cpqHeFltTolPowerSupplyModel
  • cpqHeFltTolPowerSupplySerialNumber
  • cpqHeFltTolPowerSupplyAutoRev
  • cpqHeFltTolPowerSupplyFirmwareRev
  • cpqHeFltTolPowerSupplySparePartNum
  • cpqSiServerSystemId

Supporting SNMP Trap Description: “The Power Supply is Failed on Chassis [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay], Status [cpqHeFltTolPowerSupplyStatus], Model [cpqHeFltTolPowerSupplyModel], Serial Num [cpqHeFltTolPowerSupplySerialNumber], Firmware [cpqHeFltTolPowerSupplyFirmwareRev].”

NT Event ID: 1126 (Hex)0x84350466 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Fault Tolerant Power Supply Sub-system has lost redundancy. Restore power or replace any failed or missing power supplies.

SNMP Trap: cpqHe3FltTolPowerRedundancyLost - 6032 in CPQHLTH.MIB

Symptom: The Fault Tolerant Power Supplies have lost redundancy for the specified chassis.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeFltTolPowerSupplyChassis

Supporting SNMP Trap Description: “The Power Supplies are no longer redundant on Chassis [cpqHeFltTolPowerSupplyChassis].”

NT Event ID: 1127 (Hex)0x44350467 (cpqsvmsg.dll)

Log Severity: Information (1)

Log Message: Fault Tolerant Power Supply Inserted. A hot-plug fault tolerant power supply has been inserted into the system.

SNMP Trap: cpqHe3FltTolPowerSupplyInserted - 6033 in CPQHLTH.MIB

Symptom: A Fault Tolerant Power Supply has been inserted into the specified chassis and bay location.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeFltTolPowerSupplyChassis
  • cpqHeFltTolPowerSupplyBay

Supporting SNMP Trap Description: “The Power Supply Inserted on Chassis [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay].”

NT Event ID: 1128 (Hex)0x84350468 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: Fault Tolerant Power Supply Removed. A hot-plug fault tolerant power supply has been removed from the system.

SNMP Trap: cpqHe3FltTolPowerSupplyRemoved - 6034 in CPQHLTH.MIB

Symptom: A Fault Tolerant Power Supply has been removed from the specified chassis and bay location.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeFltTolPowerSupplyChassis
  • cpqHeFltTolPowerSupplyBay

Supporting SNMP Trap Description: “The Power Supply Removed on Chassis [cpqHeFltTolPowerSupplyChassis], Bay [cpqHeFltTolPowerSupplyBay].”

NT Event ID: 1129 (Hex)0x84350469 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Fan Sub-system is in a degraded state. Replace the fan.

SNMP Trap: cpqHe3FltTolFanDegraded - 6035 in CPQHLTH.MIB

Symptom: The Fault Tolerant Fan condition has been set to degraded for the specified chassis and fan.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeFltTolFanChassis
  • cpqHeFltTolFanIndex

Supporting SNMP Trap Description: “The Fan Degraded on Chassis [cpqHeFltTolFanChassis], Fan [cpqHeFltTolFanIndex].”

NT Event ID: 1130 (Hex)0xc435046a (cpqsvmsg.dll)

Log Severity: Error (3)

Log Message: The Fan Sub-system is in a failed state. Replace the fan.

SNMP Trap: cpqHe3FltTolFanFailed - 6036 in CPQHLTH.MIB

Symptom: The Fault Tolerant Fan condition has been set to failed for the specified chassis and fan.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeFltTolFanChassis
  • cpqHeFltTolFanIndex

Supporting SNMP Trap Description: “The Fan Failed on Chassis [cpqHeFltTolFanChassis], Fan [cpqHeFltTolFanIndex].”

NT Event ID: 1131 (Hex)0x8435046b (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Fan Sub-system has lost redundancy. Replace any failed or missing fans.

SNMP Trap: cpqHe3FltTolFanRedundancyLost - 6037 in CPQHLTH.MIB

Symptom: The Fault Tolerant Fans have lost redundancy for the specified chassis.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeFltTolFanChassis

Supporting SNMP Trap Description: “The Fans are no longer redundant on Chassis [cpqHeFltTolFanChassis].”

NT Event ID: 1132 (Hex)0x4435046c (cpqsvmsg.dll)

Log Severity: Information (1)

Log Message: Fan Inserted. A hot-plug fan has been inserted into the system.

SNMP Trap: cpqHe3FltTolFanInserted - 6038 in CPQHLTH.MIB

Symptom: A Fault Tolerant Fan has been inserted into the specified chassis and fan location.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeFltTolFanChassis
  • cpqHeFltTolFanIndex

Supporting SNMP Trap Description: “The Fan Inserted on Chassis [cpqHeFltTolFanChassis], Fan [cpqHeFltTolFanIndex].”

NT Event ID: 1133 (Hex)0x8435046d (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: Fan Removed. A hot-plug fan has been removed from the system.

SNMP Trap: cpqHe3FltTolFanRemoved - 6039 in CPQHLTH.MIB

Symptom: A Fault Tolerant Fan has been removed from the specified chassis and fan location.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeFltTolFanChassis
  • cpqHeFltTolFanIndex

Supporting SNMP Trap Description: “The Fan Removed on Chassis [cpqHeFltTolFanChassis], Fan [cpqHeFltTolFanIndex].”

NT Event ID: 1134 (Hex)0xc435046e (cpqsvmsg.dll)

Log Severity: Error (3)

Log Message: A Temperature Sensor Condition has been set to failed. The system will be shut down due to this overheat condition.

SNMP Trap: cpqHe3TemperatureFailed - 6040 in CPQHLTH.MIB

Symptom: The temperature status has been set to failed in the specified chassis and location. The system is shut down due to this condition.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeTemperatureChassis
  • cpqHeTemperatureLocale

Supporting SNMP Trap Description: “Temperature Exceeded on Chassis [cpqHeTemperatureChassis], Location [cpqHeTemperatureLocale].”

NT Event ID: 1135 (Hex)0x8435046f (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: A Temperature Sensor Condition has been set to degraded. The system may or may not shut down depending on the state of the thermal degraded action value '%6'.

SNMP Trap: cpqHe3TemperatureDegraded - 6041 in CPQHLTH.MIB

Symptom: The temperature status has been set to degraded in the specified chassis and location.

The server's temperature is outside of the normal operating range. The server is shut down if the cpqHeThermalDegradedAction variable is set to shutdown (3).

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeThermalDegradedAction
  • cpqHeTemperatureChassis
  • cpqHeTemperatureLocale

Supporting SNMP Trap Description: “Temperature out of range on Chassis [cpqHeTemperatureChassis], Location [cpqHeTemperatureLocale]. Shutdown may occur.”

NT Event ID: 1136 (Hex)0x44350470 (cpqsvmsg.dll)

Log Severity: Information (1)

Log Message: A Temperature Sensor Condition has been set to OK. The system's temperature has returned to the normal operating range.

SNMP Trap: cpqHe3TemperatureOk - 6042 in CPQHLTH.MIB

Symptom: The temperature status has been set to OK in the specified chassis and location. The server's temperature has returned to the normal operating range.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeTemperatureChassis
  • cpqHeTemperatureLocale

Supporting SNMP Trap Description: “Temperature Normal on Chassis [cpqHeTemperatureChassis], Location [cpqHeTemperatureLocale].”

NT Event ID: 1137 (Hex)0x84350471 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The DC-DC power converter is in a degraded state. Replace the power converter.

SNMP Trap: cpqHe3PowerConverterDegraded - 6043 in CPQHLTH.MIB

Symptom: The DC-DC Power Converter condition has been set to degraded for the specified chassis, slot, and socket.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHePwrConvChassis
  • cpqHePwrConvSlot
  • cpqHePwrConvSocket

Supporting SNMP Trap Description: “The Power Converter Degraded on Chassis [cpqHePwrConvChassis], Slot [cpqHePwrConvSlot], Socket [cpqHePwrConvSocket].”

NT Event ID: 1138 (Hex)0xc4350472 (cpqsvmsg.dll)

Log Severity: Error (3)

Log Message: The DC-DC power converter is in a failed state. Replace the power converter.

SNMP Trap: cpqHe3PowerConverterFailed - 6044 in CPQHLTH.MIB

Symptom: The DC-DC Power Converter condition has been set to failed for the specified chassis, slot, and socket.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHePwrConvChassis
  • cpqHePwrConvSlot
  • cpqHePwrConvSocket

Supporting SNMP Trap Description: “The Power Converter Failed on Chassis [cpqHePwrConvChassis], Slot [cpqHePwrConvSlot], Socket [cpqHePwrConvSocket].”

NT Event ID: 1139 (Hex)0x84350473 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The DC-DC power converter is in a failed state. Replace System Information Agent: Health: The DC-DC Power Converter sub-system has lost redundancy. Replace any failed or degraded power converters.

SNMP Trap: cpqHe3PowerConverterRedundancyLost - 6045 in CPQHLTH.MIB

Symptom: The DC-DC Power Converters have lost redundancy for the specified chassis.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHePwrConvChassis

Supporting SNMP Trap Description: “The Power Converters are no longer redundant on Chassis [cpqHePwrConvChassis].”

NT Event ID: 1140 (Hex)0x84350474 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: Hot Plug PCI Board Removed. A hot plug PCI adapter has been removed from the system.

SNMP Trap: cpqSiHotPlugSlotBoardRemoved - 2008 in CPQSINFO.MIB

Symptom: Hot Plug Slot Board Removed. A Hot Plug Slot Board has been removed from the specified chassis and slot.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSiHotPlugSlotChassis
  • cpqSiHotPlugSlotIndex

Supporting SNMP Trap Description: “Hot Plug Slot Board Removed from Chassis [cpqSiHotPlugSlotChassis], Slot [cpqSiHotPlugSlotIndex].”

NT Event ID: 1141 (Hex)0x44350475 (cpqsvmsg.dll)

Log Severity: Information (1)

Log Message: Hot Plug PCI Board Inserted. A hot plug PCI adapter has been inserted into the system.

SNMP Trap: cpqSiHotPlugSlotBoardInserted - 2009 in CPQSINFO.MIB

Symptom: Hot Plug Slot Board Inserted. A Hot Plug Slot Board has been inserted into the specified chassis and slot.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSiHotPlugSlotChassis
  • cpqSiHotPlugSlotIndex

Supporting SNMP Trap Description: “Hot Plug Slot Board Inserted into Chassis [cpqSiHotPlugSlotChassis], Slot [cpqSiHotPlugSlotIndex].”

NT Event ID: 1142 (Hex)0xc4350476 (cpqsvmsg.dll)

Log Severity: Error (3)

Log Message: Hot Plug PCI Board Failed. A hot plug PCI adapter has failed to power up. Insure the board and all cables are installed correctly.

SNMP Trap: cpqSiHotPlugSlotPowerUpFailed - 2010 in CPQSINFO.MIB

Symptom: Hot Plug Slot Board Failed Power-Up. A Hot Plug Slot Board has failed to power up in the specified chassis and slot.

User Action: Be sure the board and all cables are installed correctly, and that the board type and revision are the same as the replaced board.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSiHotPlugSlotChassis
  • cpqSiHotPlugSlotIndex
  • cpqSiHotPlugSlotErrorStatus

Supporting SNMP Trap Description: “Hot Plug Slot Board Failed in Chassis [cpqSiHotPlugSlotChassis], Slot [cpqSiHotPlugSlotIndex], Error [cpqSiHotPlugSlotErrorStatus].”

NT Event ID: 1143 (Hex)0x44350477 (cpqsvmsg.dll)

Log Severity: Information (1)

Log Message: Rack Name Changed.

SNMP Trap: cpqRackNameChanged - 22001 in CPQRACK.MIB

Symptom: The rack name has changed. This trap indicates that an agent or utility has changed the name of the rack. Each of the server blades in each of the enclosure within the rack is updated to reflect the new rack name. It may take several minutes for the rack name change to be propagated throughout the entire rack.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackSerialNum
  • cpqRackTrapSequenceNum

Supporting SNMP Trap Description: “The rack name has changed to [cpqRackName].”

NT Event ID: 1144 (Hex)0x44350478 (cpqsvmsg.dll)

Log Severity: Information (1)

Log Message: Rack Enclosure Name Changed.

SNMP Trap: cpqRackEnclosureNameChanged - 22002 in CPQRACK.MIB

Symptom: The enclosure name has changed. This trap indicates that an agent or utility has changed the name of an enclosure within the rack. Each of the components within the rack is updated to reflect the new enclosure name. It may take several minutes for the enclosure name change to be propagated throughout the entire enclosure.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureModel
  • cpqRackCommonEnclosureSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The enclosure name has changed to [cpqRackCommonEnclosureName] in rack [cpqRackName].”

NT Event ID: 1145 (Hex)0x44350479 (cpqsvmsg.dll)

Log Severity: Information (1)

Event Title: Enclosure Removed

Log Message: This trap indicates that an enclosure has been removed from the rack.

SNMP Trap: cpqRackEnclosureRemoved - 22003 in CPQRACK.MIB

Symptom: The enclosure has been removed. This trap indicates that an enclosure has been removed from the rack.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureModel
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] has been removed from rack [cpqRackName].”

NT Event ID: 1146 (Hex)0x4435047a (cpqsvmsg.dll)

Log Severity: Information (1)

Event Title: Enclosure Inserted

Log Message: This trap indicates that an enclosure has been inserted into the rack.

SNMP Trap: cpqRackEnclosureInserted - 22004 in CPQRACK.MIB

Symptom: The enclosure has been inserted. This trap indicates that an enclosure has been inserted into the rack.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureModel
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] has been inserted into rack [cpqRackName].”

NT Event ID: 1147 (Hex)0xc435047b (cpqsvmsg.dll)

Log Severity: Error (3)

Event Title: Rack Enclosure Overheated

Log Message: This trap indicates that an enclosure temperature sensor has been tripped indicating an overheat condition.

SNMP Trap: cpqRackEnclosureTempFailed - 22005 in CPQRACK.MIB

Symptom: The enclosure temperature status has been set to failed. This trap indicates that an enclosure temperature sensor has been tripped, indicating an overheat condition.

User Action: Shut down the enclosure and possibly the rack as soon as possible. Be sure that all fans are working properly and that air flow in the rack has not been blocked.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTempLocation
  • cpqRackCommonEnclosureSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] temperature sensor in rack [cpqRackName] has been set to failed.”

NT Event ID: 1148 (Hex)0x8435047c (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Rack Enclosure Overheating

Log Message: This trap indicates that an enclosure temperature sensor has been tripped indicating a possible overheat condition.

SNMP Trap: cpqRackEnclosureTempDegraded - 22006 in CPQRACK.MIB

Symptom: The enclosure temperature status has been set to degraded. This trap indicates that an enclosure temperature sensor has been tripped, indicating a possible overheat condition.

User Action: Shut down the enclosure and possibly the rack as soon as possible. Be sure that all fans are working properly and that air flow in the rack has not been blocked.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTempLocation
  • cpqRackCommonEnclosureSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] temperature sensor in rack [cpqRackName] has been set to degraded.”

NT Event ID: 1149 (Hex)0x4435047d (cpqsvmsg.dll)

Log Severity: Information (1)

Event Title: Rack Enclosure Temperature Normal

Log Message: This trap indicates that an enclosure temperature sensor has returned to normal.

SNMP Trap: cpqRackEnclosureTempOk - 22007 in CPQRACK.MIB

Symptom: The enclosure temperature status has been set to OK. This trap indicates that an enclosure temperature sensor has returned to normal.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTempLocation
  • cpqRackCommonEnclosureSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] temperature sensor in rack [cpqRackName] has been set to ok.”

NT Event ID: 1150 (Hex)0xc435047e (cpqsvmsg.dll)

Log Severity: Error (3)

Event Title: Rack Enclosure Fan Failed

Log Message: This trap indicates that an enclosure fan has failed and less than the minimum number of fans in the redundant fan group are operating. This may result in overheating of the enclosure.

SNMP Trap: cpqRackEnclosureFanFailed - 22008 in CPQRACK.MIB

Symptom: The enclosure fan status has been set to failed. This trap indicates that an enclosure fan has failed and that no other fans in the redundant fan group are operating. This may result in the enclosure overheating.

User Action: Replace the fan as soon as possible.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureFanLocation
  • cpqRackCommonEnclosureFanSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] fan in rack [cpqRackName] has been set to failed.”

NT Event ID: 1151 (Hex)0x8435047f (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Rack Enclosure Fan Degraded

Log Message: This trap indicates that an enclosure fan has failed but other fans in the redundant fan group are still operating. This may result in overheating of the enclosure.

SNMP Trap: cpqRackEnclosureFanDegraded - 22009 in CPQRACK.MIB

Symptom: The enclosure fan status has been set to degraded. This trap indicates that an enclosure fan has failed but that other fans in the redundant fan group are still operating. This may result in the enclosure overheating.

User Action: Replace the fan as soon as possible.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureFanLocation
  • cpqRackCommonEnclosureFanSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] fan in rack [cpqRackName] has been set to degraded.”

NT Event ID: 1152 (Hex)0x44350480 (cpqsvmsg.dll)

Log Severity: Information (1)

Event Title: Rack Enclosure Fan OK

Log Message: This trap indicates that an enclosure fan has returned to normal operation.

SNMP Trap: cpqRackEnclosureFanOk - 22010 in CPQRACK.MIB

Symptom: The enclosure fan status has been set to OK. This trap indicates that an enclosure fan has returned to normal operation.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureFanLocation
  • cpqRackCommonEnclosureFanSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] fan in rack [cpqRackName] has been set to ok.”

NT Event ID: 1153 (Hex)0x84350481 (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Rack Enclosure Fan Removed

Log Message: The enclosure fan has been removed.

SNMP Trap: cpqRackEnclosureFanRemoved - 22011 in CPQRACK.MIB

Symptom: The enclosure fan has been removed.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureFanLocation
  • cpqRackCommonEnclosureFanSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] fan in rack [cpqRackName] has been removed.”

NT Event ID: 1154 (Hex)0x44350482 (cpqsvmsg.dll)

Log Severity: Information (1)

Event Title: Rack Enclosure Fan Inserted

Log Message: The enclosure fan has been inserted.

SNMP Trap: cpqRackEnclosureFanInserted - 22012 in CPQRACK.MIB

Symptom: The enclosure fan has been inserted.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureFanLocation
  • cpqRackCommonEnclosureFanSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] fan in rack [cpqRackName] has been inserted.”

NT Event ID: 1155 (Hex)0xc4350483 (cpqsvmsg.dll)

Log Severity: Error (3)

Event Title: Rack Power Supply Failed

Log Message: This trap indicates that a power supply has failed.

SNMP Trap: cpqRackPowerSupplyFailed - 22013 in CPQRACK.MIB

Symptom: The power supply status has been set to failed. This trap indicates that a power supply has failed.

User Action: Replace the power supply as soon as possible.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackPowerSupplyEnclosureName
  • cpqRackPowerSupplySerialNum
  • cpqRackPowerSupplyPosition
  • cpqRackPowerSupplyFWRev
  • cpqRackPowerSupplySparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The power supply [cpqRackPowerSupplyPosition] in enclosure [cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been set to failed.”

NT Event ID: 1156 (Hex)0x84350484 (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Rack Power Supply Degraded

Log Message: This trap indicates that a power supply has degraded.

SNMP Trap: cpqRackPowerSupplyDegraded - 22014 in CPQRACK.MIB

Symptom: The power supply status has been set to degraded. This trap indicates that a power supply has degraded.

User Action: Replace the power supply as soon as possible.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackPowerSupplyEnclosureName
  • cpqRackPowerSupplySerialNum
  • cpqRackPowerSupplyPosition
  • cpqRackPowerSupplyFWRev
  • cpqRackPowerSupplySparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The power supply [cpqRackPowerSupplyPosition] in enclosure [cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been set to degraded.”

NT Event ID: 1157 (Hex)0x44350485 (cpqsvmsg.dll)

Log Severity: Information (1)

Event Title: Rack Power Supply OK

Log Message: This trap indicates that a power supply has returned to normal operation.

SNMP Trap: cpqRackPowerSupplyOk - 22015 in CPQRACK.MIB

Symptom: The power supply status has been set to OK. This trap indicates that a power supply has returned to normal operation.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackPowerSupplyEnclosureName
  • cpqRackPowerSupplySerialNum
  • cpqRackPowerSupplyPosition
  • cpqRackPowerSupplyFWRev
  • cpqRackPowerSupplySparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The power supply [cpqRackPowerSupplyPosition] in enclosure [cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been set to ok.”

NT Event ID: 1158 (Hex)0x84350486 (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Rack Power Supply Removed

Log Message: The power supply has been removed.

SNMP Trap: cpqRackPowerSupplyRemoved - 22016 in CPQRACK.MIB

Symptom: The power supply has been removed.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackPowerSupplyEnclosureName
  • cpqRackPowerSupplySerialNum
  • cpqRackPowerSupplyPosition
  • cpqRackPowerSupplyFWRev
  • cpqRackPowerSupplySparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The power supply [cpqRackPowerSupplyPosition] in enclosure [cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been removed.”

NT Event ID: 1159 (Hex)0x44350487 (cpqsvmsg.dll)

Log Severity: Information (1)

Event Title: Rack Power Supply Inserted

Log Message: The power supply has been inserted.

SNMP Trap: cpqRackPowerSupplyInserted - 22017 in CPQRACK.MIB

Symptom: The power supply has been inserted.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackPowerSupplyEnclosureName
  • cpqRackPowerSupplySerialNum
  • cpqRackPowerSupplyPosition
  • cpqRackPowerSupplyFWRev
  • cpqRackPowerSupplySparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The power supply [cpqRackPowerSupplyPosition] in enclosure [cpqRackPowerSupplyEnclosureName] in rack [cpqRackName] has been inserted.”

NT Event ID: 1160 (Hex)0x84350488 (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Rack Power Subsystem Not Redundant

Log Message: The rack power subsystem is no longer in a redundant state.

SNMP Trap: cpqRackPowerSubsystemNotRedundant - 22018 in CPQRACK.MIB

Symptom: The rack power subsystem is no longer in a redundant state.

User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackPowerEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The power subsystem in enclosure [cpqRackPowerEnclosureName] in rack [cpqRackName] is no longer redundant.”

NT Event ID: 1161 (Hex)0x84350489 (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Rack Power Subsystem Input Voltage Problem

Log Message: The rack power supply detected an input line voltage problem.

SNMP Trap: cpqRackPowerSubsystemLineVoltageProblem - 22019 in CPQRACK.MIB

Symptom: The rack power supply detected an input line voltage problem.

User Action: Check the power input for the power supply or replace any failed power supplies as soon as possible.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackPowerSupplyEnclosureName
  • cpqRackPowerSupplyPosition
  • cpqRackPowerSupplyFWRev
  • cpqRackPowerSupplyInputLineStatus
  • cpqRackPowerSupplySparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The rack power supply detected an input line voltage problem in power supply [cpqRackPowerSupplyPosition], enclosure [cpqRackPowerSupplyEnclosureName], rack [cpqRackName].”

NT Event ID: 1162 (Hex)0x8435048a (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Rack Power Subsystem Overload

Log Message: The rack power subsystem overload condition.

SNMP Trap: cpqRackPowerSubsystemOverloadCondition - 22020 in CPQRACK.MIB

Symptom: The rack power subsystem overload condition.

User Action: Replace any failed power supplies as soon as possible to return the system to a redundant state.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackPowerEnclosureName
  • cpqRackCommonEnclosureSparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The power subsystem in enclosure [cpqRackPowerEnclosureName] in rack [cpqRackName] is in an overload condition.”

NT Event ID: 1163 (Hex)0xc435048b (cpqsvmsg.dll)

Log Severity: Error (3)

Event Title: Server Power Shedding Shutdown

Log Message: Server shutdown due to power shedding.

SNMP Trap: cpqRackPowerShedAutoShutdown - 22021 in CPQRACK.MIB

Symptom: Server shutdown due to power shedding. The server blade was shut down due to a lack of power.

User Action: Check power connections or add power supplies.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackServerBladeEnclosureName
  • cpqRackServerBladePosition
  • cpqRackServerBladeSparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “The server shutdown due to lack of power blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].”

NT Event ID: 1164 (Hex)0xc435048c (cpqsvmsg.dll)

Log Severity: Error (3)

Event Title: Server Power On Prevented

Log Message: Server power on prevented to preserve redundancy.

SNMP Trap: cpqRackServerPowerOnFailedNotRedundant - 22022 in CPQRACK.MIB

Symptom: Server power on prevented to preserve redundancy. There is not enough power to power on the server blade and maintain redundancy for the other blades in the enclosure.

User Action: Check power connections or add power supplies.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackServerBladeEnclosureName
  • cpqRackServerBladePosition
  • cpqRackServerBladeSparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Server power on prevented to preserve redundancy in blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].”

NT Event ID: 1165 (Hex)0xc435048d (cpqsvmsg.dll)

Log Severity: Error (3)

Event Title: Not Enough Power To Power On

Log Message: Inadequate power to power on.

SNMP Trap: cpqRackServerPowerOnFailedNotEnoughPower - 22023 in CPQRACK.MIB

Symptom: Inadequate power to power on. There is not enough power to power on the server blade.

User Action: Check power connections or add power supplies.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackServerBladeEnclosureName
  • cpqRackServerBladePosition
  • cpqRackServerBladeSparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Inadequate power to power on blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].”

NT Event ID: 1166 (Hex)0xc435048e (cpqsvmsg.dll)

Log Severity: Error (3)

Event Title: Inadequate Power To Power On

Log Message: There is not enough power to power on the server blade. The server enclosure micro-controller was not found.

SNMP Trap: cpqRackServerPowerOnFailedEnclosureNotFound - 22024 in CPQRACK.MIB

Symptom: Inadequate power to power on. There is not enough power to power on the server blade. The server enclosure micro-controller was not found.

User Action: Check server enclosure connections or add power supplies.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackServerBladeEnclosureName
  • cpqRackServerBladePosition
  • cpqRackServerBladeSparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Inadequate power to power on blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].”

NT Event ID: 1167 (Hex)0xc435048f (cpqsvmsg.dll)

Log Severity: Error (3)

Event Title: Inadequate Power To Power On

Log Message: There is not enough power to power on the server blade. The power enclosure micro-controller was not found.

SNMP Trap: cpqRackServerPowerOnFailedPowerChassisNotFound - 22025 in CPQRACK.MIB

Symptom: Inadequate power to power on. There is not enough power to power on the server blade. The power enclosure micro-controller was not found.

User Action: Check power enclosure connections or add power supplies.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackServerBladeEnclosureName
  • cpqRackServerBladePosition
  • cpqRackServerBladeSparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Inadequate power to power on blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].”

NT Event ID: 1168 (Hex)0x84350490 (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Server Power On Via Manual Override

Log Message: Server power on via manual override.

SNMP Trap: cpqRackServerPowerOnManualOverride - 22026 in CPQRACK.MIB

Symptom: Server power on via manual override. The server blade was powered on by a manual override.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackServerBladeEnclosureName
  • cpqRackServerBladePosition
  • cpqRackServerBladeSparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Server power on via manual override on blade [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].”

NT Event ID: 1169 (Hex)0x84350491 (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Fuse or Breaker Tripped

Log Message: The fuse has been tripped.

SNMP Trap: cpqRackFuseOpen - 22027 in CPQRACK.MIB

Symptom: Fuse open. The fuse has been tripped.

User Action: Check enclosure and blade power connections and reset the fuse.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureFuseLocation
  • cpqRackCommonEnclosureSparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Fuse open fuse [cpqRackCommonEnclosureFuseLocation], in enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName].”

NT Event ID: 1170 (Hex)0x84350492 (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Server Blade Removed

Log Message: The server blade has been removed from the enclosure.

SNMP Trap: cpqRackServerBladeRemoved - 22028 in CPQRACK.MIB

Symptom: Server blade removed. The server blade has been removed from the enclosure.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackServerBladeEnclosureName
  • cpqRackServerBladeName
  • cpqRackServerBladePosition
  • cpqRackServerBladeSparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Server blade [cpqRackServerBladeName] removed from position [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].”

NT Event ID: 1171 (Hex)0x44350493 (cpqsvmsg.dll)

Log Severity: Information (1)

Event Title: Server Blade Inserted

Log Message: The server blade has been inserted from the enclosure.

SNMP Trap: cpqRackServerBladeInserted - 22029 in CPQRACK.MIB

Symptom: Server blade inserted. The server blade has been inserted into the enclosure.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackServerBladeEnclosureName
  • cpqRackServerBladeName
  • cpqRackServerBladePosition
  • cpqRackServerBladeSparePartNumber
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Server blade [cpqRackServerBladeName] inserted into position [cpqRackServerBladePosition], in enclosure [cpqRackServerBladeEnclosureName], in rack [cpqRackName].”

NT Event ID: 1172 (Hex)0x84350494 (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Rack Power Subsystem Not Load Balanced

Log Message: The power subsystem is out of balance for this power enclosure.

SNMP Trap: cpqRackPowerChassisNotLoadBalanced - 22030 in CPQRACK.MIB

Symptom: Power subsystem not load balanced. The power subsystem is out of balance for this power enclosure.

User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies. Add additional power supplies if needed.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Power subsystem not load balanced in enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName].”

NT Event ID: 1173 (Hex)0x84350495 (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Power Subsystem DC Power Problem

Log Message: There is a power subsystem DC power problem for this enclosure.

SNMP Trap: cpqRackPowerChassisDcPowerProblem - 22031 in CPQRACK.MIB

Symptom: Power subsystem DC power problem. There is a power subsystem DC power problem for this power enclosure.

User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Power subsystem DC power problem in enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName].”

NT Event ID: 1174 (Hex)0x84350496 (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Power Subsystem Facility AC Power Problem

Log Message: The AC facility input power has been exceeded for this power enclosure.

SNMP Trap: cpqRackPowerChassisAcFacilityPowerExceeded - 22032 in CPQRACK.MIB

Symptom: Power subsystem AC facility input power exceeded for this power enclosure.

User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Power subsystem AC facility input power exceeded in enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName].”

NT Event ID: 1175 (Hex)0x84350497 (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Power Subsystem Unknown Power Consumption

Log Message: There is an unknown power consumer drawing power.

SNMP Trap: cpqRackPowerUnknownPowerConsumption - 22033 in CPQRACK.MIB

Symptom: Unknown power consumption. There is an unknown power consumer drawing power.

User Action: Check the power enclosure and power supplies. Replace any failed or degraded power supplies.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Unknown power consumption in rack [cpqRackName].”

NT Event ID: 1176 (Hex)0x84350498 (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Power Subsystem Load Balancing Wire Missing

Log Message: The power subsystem load balancing wire missing.

SNMP Trap: cpqRackPowerChassisLoadBalancingWireMissing - 22034 in CPQRACK.MIB

Symptom: Power subsystem load balancing wire missing. The power subsystem load balancing wire is missing.

User Action: Connect the load balancing wire.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Power subsystem load balancing wire missing for enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName].”

NT Event ID: 1177 (Hex)0x84350499 (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Power Subsystem Too Many Power Enclosures

Log Message: The maximum number of power enclosures has been exceeded.

SNMP Trap: cpqRackPowerChassisTooManyPowerChassis - 22035 in CPQRACK.MIB

Symptom: Power subsystem has too may power enclosures. The maximum number of power enclosures has been exceeded.

User Action: Remove the extra power enclosure.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Power subsystem has too may power enclosures [cpqRackCommonEnclosureName], in rack [cpqRackName].”

NT Event ID: 1178 (Hex)0x8435049a (cpqsvmsg.dll)

Log Severity: Warning (2)

Event Title: Power Subsystem Configuration Error

Log Message: The power subsystem has been improperly configured.

SNMP Trap: cpqRackPowerChassisConfigError - 22036 in CPQRACK.MIB

Symptom: Power subsystem improperly configured. The power subsystem has been improperly configured.

User Action: Check the cabling of the power enclosure.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqRackName
  • cpqRackUid
  • cpqRackCommonEnclosureName
  • cpqRackCommonEnclosureSerialNum
  • cpqRackCommonEnclosureSparePartNumber
  • cpqRackCommonEnclosureTrapSequenceNum

Supporting SNMP Trap Description: “Power subsystem has been improperly configured in enclosure [cpqRackCommonEnclosureName], in rack [cpqRackName].”

NT Event ID: 1179 (Hex) 0x8435049B (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Management Processor is in reset state. The data contains the error code.

SNMP Trap: cpqHeManagementProcInReset - 6061 in CPQHLTH.MIB

Symptom: The Management processor is currently in reset. The management processor is currently in the process of being reset because of a firmware update or some other event.

User action: None

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “The Management processor is in the process of being reset.”

NT Event ID: 1180 (Hex) 0x0435049c (cpqsvmsg.dll)

Log Severity: Informational (1)

Log Message: The Management Processor has successfully reset and is now available again. The data contains the error code.

SNMP Trap: cpqHeManagementProcReady - 6062 in CPQHLTH.MIB

Symptom: The Management processor is ready. The management processor has successfully reset and is now available again.

User action: None

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “The Management processor is ready after a successfull reset”

NT Event ID: 1181 (Hex) 0x8435049D (cpqsvmsg.dll)

Log Severity: Warning (3)

Log Message: The Management Processor has not reset successfully and is not operational. The data contains the error code.

SNMP Trap: cpqHeManagementProcFailedReset - 6063 in CPQHLTH.MIB

Symptom: The Management processor failed reset. The management processor was not successfully reset and is not operational.

User action: Reset the management procesessor again or re-flash the management processor firmware.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: The Management processor failed reset.

NT Event ID: 1182 (Hex)0x4435049EL

Log Severity: Informational

Log Message: USB storage device '%5' attached. The data contains the error code.

SNMP Trap: 1008 in CPQSTDEQ.MIB

Symptom: The USB key is attached to the server.

User Action: None required.

Supporting SNMP Trap Data:

  • sysName,
  • cpqHoTrapFlags
  • cpqSeUSBDeviceType
  • cpqSeUSBDeviceName

Supporting SNMP Trap Description: This trap is sent when a USB storage device has been attached.

Symbolic Name: CPQ_STD_USB_DEV_ATTACHED

NT Event ID: 1183 (Hex)0x4435049FL

Log Severity: Informational

Log Message: USB storage device '%5' removed. The data contains the error code.

SNMP TRAP: 1009 in CPQSTDEQ.MIB

Symptom: The USB key has been removed from the server.

User Action: None required.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSeUSBDeviceType
  • cpqSeUSBDeviceName

Supporting SNMP Trap Description: This trap is sent when a attached USB storage device is removed.

Symbolic Name: CPQ_STD_USB_DEV_REMOVED