Event Identifiers 1101-1199

NT Event ID: 1101 (Hex)0x8435044d (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Side Panel Removed.

Log Message: The side panel has been removed on the %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4.

SNMP Trap: cpqSs3SidePanelRemoved - 8013 in CPQSTSYS.MIB

Symptom: Storage System side panel is removed. The side panel status has been set to removed. The storage system's side panel is not in a properly installed state. This situation may result in improper cooling of the drives in the storage system due to air flow changes caused by the missing side panel.

User Action: Replace the storage system side panel.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsBoxSidePanelStatus

Supporting SNMP Trap Description: “Side panel is removed from unit.”

NT Event ID: 1102 (Hex)0x4435044e (cpqstmsg.dll)

Log Severity: Information (1)

Event Title: Storage System Side Panel In Place.

Log Message: The side panel has been replaced on the %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4.

SNMP Trap: cpqSs3SidePanelInPlace - 8012 in CPQSTSYS.MIB

Symptom: Storage System side panel is in place. The side panel status has been set to in place. The storage system's side panel has returned to a properly installed state.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsBoxSidePanelStatus

Supporting SNMP Trap Description: “Side panel is re-installed on unit.”

NT Event ID: 1104 (Hex)0x84350450 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Fault Tolerant Power Supply Degraded.

Log Message: The fault tolerant power supply in the %6 %7 storage system connected to SCSI bus %5 of the controller in slot %4 has a degraded status. Restore power or replace any failed power supply.

SNMP Trap: cpqSs4PwrSupplyDegraded - 8015 in CPQSTSYS.MIB

Symptom: A storage system power supply status has been set to degraded.

User Action: Restore power or replace any failed storage system power supply.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsBoxFltTolPwrSupplyStatus

Supporting SNMP Trap Description: “A storage system power supply unit has become degraded.”

NT Event ID: 1107 (Hex)0xc4350453 (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: SCSI Tape Drive Status Change.

Log Message: The tape drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.

SNMP Trap: cpqTape4PhyDrvStatusChange - 5016 in CPQSCSI.MIB

Symptom: Tape Drive Status Change. The Storage Agent has detected a change in the status of a Tape drive. The current physical drive status is indicated in the cpqTapePhyDrvStatus variable.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqTapePhyDrvCntlrIndex
  • cpqTapePhyDrvBusIndex
  • cpqTapePhyDrvScsiIdIndex
  • cpqTapePhyDrvStatus

Supporting SNMP Trap Description: “Status is now [cpqTapePhyDrvStatus].”

NT Event ID: 1119 (Hex)0x8435045f (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: SCSI Tape Drive Head Needs Cleaning.

Log Message: The tape drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 needs to have a cleaning tape inserted and run.

SNMP Trap: cpqTape3PhyDrvCleaningRequired - 5008 in CPQSCSI.MIB

Symptom: Tape Drive Cleaning Required trap. The Insight Agent has detected a tape drive that needs to have a cleaning tape inserted and run. This causes the tape drive heads to be cleaned.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqTapePhyDrvCondition

Supporting SNMP Trap Description: “Status is now [cpqTapePhyDrvCondition].”

NT Event ID: 1120 (Hex)0x84350460 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: SCSI Tape Drive Cleaning Tape Needs Replacing.

Log Message: The tape drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 needs the cleaning tape replaced.

SNMP Trap: cpqTape3PhyDrvCleanTapeReplace - 5009 in CPQSCSI.MIB

Symptom: Tape Drive Cleaning Tape Needs Replacing. The Insight Agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new cleaning tape.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqTapePhyDrvCondition

Supporting SNMP Trap Description: “Status is now [cpqTapePhyDrvCondition].”

NT Event ID: 1121 (Hex)0x84350461 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: IDE Drive Status Degraded.

Log Message: The IDE drive %4 has a degraded status and should be scheduled for replacement.

SNMP Trap: cpqIdeDriveDegraded - 14001 in CPQIDE.MIB

Symptom: An IDE drive status has been set to degraded.

User Action: The drive should be scheduled for replacement. For detailed information on a component replacement, see the appropriate Maintenance and Service Guide.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqIdeIdentIndex

Supporting SNMP Trap Description: “IDE drive [cpqIdeIdentIndex] has become degraded.”

NT Event ID: 1122 (Hex)0x44350462 (cpqstmsg.dll)

Log Severity: Information (1)

Event Title: IDE Drive Status OK.

Log Message: The IDE drive %4 has returned to a normal operating condition.

SNMP Trap: cpqIdeDriveOk - 14002 in CPQIDE.MIB

Symptom: An IDE drive status has been set to OK.

User Action: None.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqIdeIdentIndex

Supporting SNMP Trap Description: “IDE drive [cpqIdeIdentIndex] has returned to normal operating condition.”

NT Event ID: 1145 (Hex)0xc4350479 (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: External Array Logical Drive Status Change.

Log Message: Logical drive number %5 on array “%4” has a new status of %6.

SNMP Trap: cpqExtArrayLogDrvStatusChange - 16022 in CPQFCA.MIB

Symptom: External Array Logical Drive Status Change. This trap indicates that the agent has detected a change in the status of an External Array logical drive. The variable cpqFcaLogDrvStatus indicates the current logical drive status.

User Action: If the logical drive status is failed, examine the array for failed drives that need replacement.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqFcaLogDrvBoxIndex
  • cpqFcaLogDrvIndex
  • cpqFcaLogDrvStatus
  • cpqFcaLogDrvOsName
  • cpqFcaLogDrvFaultTol
  • cpqFcaLogDrvSize

Supporting SNMP Trap Description: “Status is now [cpqFcaLogDrvStatus].”

NT Event ID: 1146 (Hex)0xc435047a (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: External Array Physical Drive Status Change.

Log Message: The physical drive in port %5, bay %6 on array “%4” has a new status of %7.

SNMP Trap: cpqFca2PhyDrvStatusChange - 16016 in CPQFCA.MIB

Symptom: External Array Physical Drive Status Change. This trap indicates that the agent has detected a change in the status of a physical drive. The variable cpaFcaPhyDrvStatus indicates the current physical drive status.

User Action: If the physical drive status is threshExceeded(4), predictiveFailure(5) or failed(6), replace the drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqFcaPhyDrvBusNumber
  • cpqFcaPhyDrvBay
  • cpqFcaPhyDrvStatus
  • cpqFcaPhyDrvModel
  • cpqFcaPhyDrvSerialNum
  • cpqFcaPhyDrvFWRev
  • cpqFcaPhyDrvFailureCode

Supporting SNMP Trap Description: “Status is now [cpqFcaPhyDrvStatus] for a physical drive on bus [cpqFcaPhyDrvBusNumber], bay [cpqFcaPhyDrvBay].”

NT Event ID: 1147 (Hex)0xc435047b (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: External Array Spare Drive Status Change.

Log Message: The spare drive in port %5, bay %6 on array “%4” has a new status of %7.

SNMP Trap: cpqFcaSpareStatusChange - 16002 in CPQFCA.MIB

Symptom: External Array Spare Drive Status Change. This trap indicates that the agent has detected a change in the status of an External Channel Array spare drive. The variable cpqFcaSpareStatus indicates the current spare drive status. The variable cpqFcaSpareBusNumber indicates the SCSI bus number associated with this drive.

User Action: If the spare drive status is failed, replace the drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqFcaSpareBusNumber
  • cpqFcaSpareBay
  • cpqFcaSpareStatus

Supporting SNMP Trap Description: “Spare Status is now [cpqFcaSpareStatus] on bus [cpqFcaSpareBusNumber].”

NT Event ID: 1148 (Hex)0xc435047c (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: External Array Accelerator Status Change.

Log Message: The array accelerator board attached to the external controller in I/O slot %5 of array “%4” has a new status of %6.

SNMP Trap: cpqFca2AccelStatusChange - 16017 in CPQFCA.MIB

Symptom: External Array Accelerator Board Status Change. This trap indicates that the agent has detected a change in the status of an Array Accelerator Cache Board. The current status is represented by the variable cpqFcaAccelStatus.

User Action: If the accelerator board status is permDisabled(5), you may need to replace the accelerator board.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqFcaAccelBoxIoSlot
  • cpqFcaAccelStatus
  • cpqFcaCntlrModel
  • cpqFcaAccelSerialNumber
  • cpqFcaAccelTotalMemory
  • cpqFcaAccelErrCode

Supporting SNMP Trap Description: “Status is now [cpqFcaAccelStatus].”

NT Event ID: 1149 (Hex)0xc435047d (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: External Array Accelerator Bad Data.

Log Message: The array accelerator board attached to the external controller in I/O slot %5 of array “%4” is reporting that it contains bad cached data.

SNMP Trap: cpqFca2AccelBadDataTrap - 16018 in CPQFCA.MIB

Symptom: External Array Accelerator Board Bad Data. This trap indicates that the agent has detected an Array Accelerator Cache Board that has lost battery power. If data was being stored in the accelerator memory when the system lost power, that data has been lost.

User Action: Verify that no data has been lost.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqFcaAccelBoxIoSlot
  • cpqFcaCntlrModel
  • cpqFcaAccelSerialNumber
  • cpqFcaAccelTotalMemory

Supporting SNMP Trap Description: “Accelerator lost battery power. Data Loss possible.”

NT Event ID: 1150 (Hex)0xc435047e (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: External Array Accelerator Battery Failed.

Log Message: The array accelerator board attached to the external controller in I/O slot %5 of array “%4” is reporting a battery failure.

SNMP Trap: cpqFca2AccelBatteryFailed - 16019 in CPQFCA.MIB

Symptom: External Array Accelerator Board Battery failed. This trap indicates that the agent has detected a battery failure associated with the Array Accelerator Cache Board.

User Action: Replace the Accelerator Cache Board.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqFcaAccelBoxIoSlot
  • cpqFcaCntlrModel
  • cpqFcaAccelSerialNumber
  • cpqFcaAccelTotalMemory

Supporting SNMP Trap Description: “Battery status is failed.”

NT Event ID: 1151 (Hex)0xc435047f (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: External Array Controller Status Change.

Log Message: The external controller in I/O slot %5 of array “%4” has a new status of %6.

SNMP Trap: cpqFca2CntlrStatusChange - 16020 in CPQFCA.MIB

Symptom: External Array Controller Status Change. This trap indicates that the agent has detected a change in the status of an External Array Controller. The variable cpqFcaCntlrStatus indicates the current controller status.

User Action: If the controller status is offline(4), access to the storage box has been lost. Check the storage box and all fibre channel connections for problems.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqFcaCntlrBoxIoSlot
  • cpqFcaCntlrStatus
  • cpqFcaCntlrModel
  • cpqFcaCntlrSerialNumber
  • cpqFcaAccelTotalMemory

Supporting SNMP Trap Description: “Status is now [cpqFcaCntlrStatus].”

NT Event ID: 1152 (Hex)0x84350480 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Fan Module Status Change.

Log Message: Storage system “%4” fan module at location %5 has a new status of %6.

SNMP Trap: cpqSsEx2FanStatusChange - 8020 in CPQSTSYS.MIB

Symptom: Storage system fan status change. The agent has detected a change in the fan module status of a storage system. The variable cpqSsFanModuleStatus indicates the current fan status.

User Action: If the fan status is degraded or failed, replace any failed fans.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqSsFanModuleLocation
  • cpqSsFanModuleStatus
  • cpqSsFanModuleSerialNumber
  • cpqSsFanModuleBoardRevision

Supporting SNMP Trap Description: “Storage system fan status changed to [cpqSsFanModuleStatus].”

NT Event ID: 1153 (Hex)0x84350481 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Power Supply Status Change.

Log Message: Storage system “%4” power supply in bay %5 has a new status of %6.

SNMP Trap: cpqSsEx2PowerSupplyStatusChange - 8021 in CPQSTSYS.MIB

Symptom: Storage system power supply status change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsPowerSupplyStatus indicates the current status.

User Action: If the power supply status is failed, restore power or replace the failed power supply.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqSsPowerSupplyBay
  • cpqSsPowerSupplyStatus
  • cpqSsPowerSupplySerialNumber
  • cpqSsPowerSupplyBoardRevision
  • cpqSsPowerSupplyFirmwareRevision

Supporting SNMP Trap Description: “Storage system power supply status changed to [cpqSsPowerSupplyStatus].”

NT Event ID: 1154 (Hex)0x84350482 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Power Supply UPS Status Change.

Log Message: The UPS attached to storage system “%4” power supply bay %5 has a new status of %7.

SNMP Trap: cpqSsExPowerSupplyUpsStatusChange - 8018 in CPQSTSYS.MIB

Symptom: Storage system power supply UPS status change. The agent has detected a change status of a UPS attached to a storage system power supply. The variable cpqSsPowerSupplyUpsStatus indicates the current status.

User Action: If the UPS status is powerFailed(4) or batteryLow(5), restore power to the UPS.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqSsPowerSupplyBay
  • cpqSsPowerSupplyUpsStatus

Supporting SNMP Trap Description: “Storage system power supply UPS status changed to [cpqSsPowerSupplyUpsStatus].”

NT Event ID: 1155 (Hex)0x84350483 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Temperature Sensor Status Change.

Log Message: Storage system “%4” temperature sensor at location %5 has a new status of %6 and a current temperature value of %7 celsius.

SNMP Trap: cpqSsExTempSensorStatusChange - 8019 in CPQSTSYS.MIB

Symptom: Storage system temperature sensor status change. The agent has detected a change in the status of a storage system temperature sensor. The variable cpqSsTempSensorStatus indicates the current status.

User Action: If the temperature status is degraded or failed, shut down the storage system as soon as possible. Be sure that the storage system environment is being cooled properly and that no components are overheated.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqSsTempSensorLocation
  • cpqSsTempSensorStatus
  • cpqSsTempSensorCurrentValue

Supporting SNMP Trap Description: “Storage system temperature sensor status changed to [cpqSsTempSensorStatus].”

NT Event ID: 1156 (Hex)0x84350484 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: SCSI Tape Library Failed.

Log Message: The SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has encountered an error.

SNMP Trap: cpqTape3LibraryFailed - 5010 in CPQSCSI.MIB

Symptom: Tape Library Error. The Insight Agent has detected that an autoloader unit has encountered an error.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqTapeLibrarySerialNumber

Supporting SNMP Trap Description: “Tape library [cpqTapeLibrarySerialNumber] is not operational.”

NT Event ID: 1157 (Hex)0x84350485 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: SCSI Tape Library OK.

Log Message: The SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has recovered from errors.

SNMP Trap: cpqTape3LibraryOkay - 5011 in CPQSCSI.MIB

Symptom: Tape Library Okay. The Insight Agent has detected that an autoloader unit has recovered from errors.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqTapeLibrarySerialNumber

Supporting SNMP Trap Description: “Tape Library [cpqTapeLibrarySerialNumber] Recovered.”

NT Event ID: 1158 (Hex)0x84350486 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: SCSI Tape Library Degraded.

Log Message: The SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 is in a degraded condition.

SNMP Trap: cpqTape3LibraryDegraded - 5012 in CPQSCSI.MIB

Symptom: Tape Library Degraded. The Insight Agent has detected that an autoloader unit is in a degraded condition.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqTapeLibrarySerialNumber

Supporting SNMP Trap Description: “Tape library [cpqTapeLibrarySerialNumber] is in a degraded condition.”

NT Event ID: 1159 (Hex)0x84350487 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: SCSI Tape Library Door Open.

Log Message: The SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a door open, so the unit is not operational.

SNMP Trap: cpqTape3LibraryDoorOpen - 5013 in CPQSCSI.MIB

Symptom: Tape Library Door Open. The Insight Agent has detected that the door on an autoloader is open, so the unit is not operational.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqTapeLibrarySerialNumber

Supporting SNMP Trap Description: “Tape library [cpqTapeLibrarySerialNumber] door opened.”

NT Event ID: 1160 (Hex)0x84350488 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: SCSI Tape Library Door Closed.

Log Message: The SCSI tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a closed door and is now operational.

SNMP Trap: cpqTape3LibraryDoorClosed - 5014 in CPQSCSI.MIB

Symptom: Tape Library Door Closed. The Insight Agent has detected that the door on an autoloader has closed.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqTapeLibrarySerialNumber

Supporting SNMP Trap Description: “Tape library [cpqTapeLibrarySerialNumber] door closed.”

NT Event ID: 1161 (Hex)0xc4350489 (cpqstmsg.dll)

Log Severity: Error (3)

Event Title: SCSI CD Library Status Change.

Log Message: The CD Library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.

SNMP Trap: cpqScsiCdLibraryStatusChange - 5015 in CPQSCSI.MIB

Symptom: CD Library Status Change. The Insight Agent has detected a change in the status of a CD Library device. The current CD Library status is indicated in the cpqScsiCdLibraryStatus variable.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqCdLibraryCntlrIndex
  • cpqCdLibraryBusIndex
  • cpqCdLibraryScsiIdIndex
  • cpqCdLibraryStatus

Supporting SNMP Trap Description: “Status is now [cpqCdLibraryStatus].”

NT Event ID: 1164 (Hex)0x8435048c (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Controller Status Change.

Log Message: The Drive Array Controller in slot %4 has a new status of %5.

SNMP Trap: cpqDa5CntlrStatusChange - 3028 in CPQIDA.MIB

Symptom: Controller Status Change. This trap indicates that the agent has detected a change in the status of a drive array controller. The variable cpqDaCntlrBoardStatus indicates the current controller status.

User Action: If the board status is generalFailure(3), you may need to replace the controller. If the board status is cableProblem(4), check the cable connections between the controller and the storage system.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrSlot
  • cpqDaCntlrBoardStatus
  • cpqDaCntlrModel
  • cpqDaCntlrSerialNumber
  • cpqDaCntlrFWRev
  • cpqDaAccelTotalMemory

Supporting SNMP Trap Description: “Status is now [cpqDaCntlrBoardStatus].”

NT Event ID: 1165 (Hex)0x8435048d (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Controller Active.

Log Message: The Drive Array Controller in slot %4 has become the active controller.

SNMP Trap: cpqDaCntlrActive - 3016 in CPQIDA.MIB

Symptom: Controller Active. This trap indicates that the agent has detected that a backup array controller in a duplexed pair has switched over to the active role. The variable cpqDaCntlrSlot indicates the active controller slot, and cpqDaCntlrPartnerSlot indicates the backup.

User Action: Check the partner controller for problems. If this was the result of a user initiated switch-over, no action is required.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrSlot
  • cpqDaCntlrPartnerSlot

Supporting SNMP Trap Description: “Controller in slot [cpqDaCntlrSlot] is now active.”

NT Event ID: 1173 (Hex)0x84350495 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Fibre Channel Tape Controller Status Change.

Log Message: Fibre Channel tape controller with world wide name “%4” has a new status of %5.

SNMP Trap: cpqFcTapeCntlrStatusChange - 16008 in CPQFCA.MIB

Symptom: Fibre Channel Tape Controller Status Change. This trap indicates that the agent has detected a change in the status of a Fiber Channel Tape Controller. The variable cpqFcTapeCntlrStatus indicates the current tape controller status. The variable cpqFcTapeCntlrWWN indicates the unique tape controller world wide name associated with this controller.

User Action: If the tape controller status is offline, access to the tape library and tapes has been lost. Check the tape library and all Fibre connections for problems.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqFcTapeCntlrWWN
  • cpqFcTapeCntlrStatus

Supporting SNMP Trap Description: “Status is now [cpqFcTapeCntlrStatus] for tape controller [cpqFcTapeCntlrWWN].”

NT Event ID: 1174 (Hex)0x84350496 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Fibre Channel Tape Library Status Change.

Log Message: The Fibre Channel tape library on tape controller with world wide name “%4”, SCSI bus %5, SCSI target %6, has a new status of %7.

SNMP Trap: cpqFcTapeLibraryStatusChange - 16009 in CPQFCA.MIB

Symptom: Fibre Channel Tape Library Status Change. This trap indicates that the agent has detected a change in the status of a Fiber Channel Tape library. The variable cpqFcTapeLibraryStatus indicates the current tape library status. The variable cpqFcTapeLibraryScsiTarget indicates the SCSI ID of the tape library.

User Action: If the tape library is failed or is offline, check the tape library front panel and all fibre channel connections.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqFcTapeCntlrWWN
  • cpqFcTapeLibraryScsiBus
  • cpqFcTapeLibraryScsiTarget
  • cpqFcTapeLibraryScsiLun
  • cpqFcTapeLibraryStatus

Supporting SNMP Trap Description: “Status is now [cpqFcTapeLibraryStatus] for the tape library.”

NT Event ID: 1175 (Hex)0x84350497 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Fibre Channel Tape Library Door Status Change.

Log Message: The Fibre Channel tape library on tape controller with world wide name “%4”, SCSI bus %5, SCSI target %6, has a new door status of %7.

SNMP Trap: cpqFcTapeLibraryDoorStatusChange - 16010 in CPQFCA.MIB

Symptom: Fibre Channel Tape Library Door Status Change. This trap indicates that the agent has detected a change in the door status of a Fiber Channel Tape library. The variable cpqFcTapeLibraryDoorStatus indicates the current tape library door status. The variable cpqFcTapeLibraryScsiTarget indicates the SCSI ID of the tape library.

User Action: If the tape library door is open, close the tape library door.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqFcTapeCntlrWWN
  • cpqFcTapeLibraryScsiBus
  • cpqFcTapeLibraryScsiTarget
  • cpqFcTapeLibraryScsiLun
  • cpqFcTapeLibraryDoorStatus

Supporting SNMP Trap Description: “The door is [cpqFcTapeLibraryDoorStatus] for tape library.”

NT Event ID: 1176 (Hex)0x84350498 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Fibre Channel Tape Drive Status Change.

Log Message: The Fibre Channel tape drive on tape controller with world wide name “%4”, SCSI bus %5, SCSI target %6, has a new status of %7.

SNMP Trap: cpqFcTapeDriveStatusChange - 16011 in CPQFCA.MIB

Symptom: Fibre Channel Tape Drive Status Change. This trap indicates that the agent has detected a change in the status of a Fiber Channel Tape Drive. The variable cpqFcTapeDriveStatus indicates the current tape status. The variable cpqFcTapeDriveScsiTarget indicates the SCSI ID of the tape drive.

User Action: If the tape is failed or is offline, check the tape and all fibre channel connections.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqFcTapeCntlrWWN
  • cpqFcTapeDriveScsiBus
  • cpqFcTapeDriveScsiTarget
  • cpqFcTapeDriveScsiLun
  • cpqFcTapeDriveStatus

Supporting SNMP Trap Description: “Status is now [cpqFcTapeDriveStatus] for a tape drive.”

NT Event ID: 1177 (Hex)0x84350499 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Fibre Channel Tape Drive Cleaning Required.

Log Message: The Fibre Channel tape drive on tape controller with world wide name “%4”, SCSI bus %5, SCSI target %6, requires cleaning.

SNMP Trap: cpqFcTapeDriveCleaningRequired - 16012 in CPQFCA.MIB

Symptom: Fibre Channel Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have a cleaning tape inserted and run. This causes the tape drive heads to be cleaned.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqFcTapeCntlrWWN
  • cpqFcTapeDriveScsiBus
  • cpqFcTapeDriveScsiTarget
  • cpqFcTapeDriveScsiLun

Supporting SNMP Trap Description: “Cleaning is needed for tape drive.”

NT Event ID: 1178 (Hex)0x8435049a (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Fibre Channel Tape Drive Replace Cleaning Tape.

Log Message: The cleaning tape in the Fibre Channel tape drive on tape controller with world wide name “%4”, SCSI bus %5, SCSI target %6, needs to be replaced.

SNMP Trap: cpqFcTapeDriveCleanTapeReplace - 16013 in CPQFCA.MIB

Symptom: Fibre Channel Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new cleaning tape.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqFcTapeCntlrWWN
  • cpqFcTapeDriveScsiBus
  • cpqFcTapeDriveScsiTarget
  • cpqFcTapeDriveScsiLun

Supporting SNMP Trap Description: “Cleaning tape needs replacing.”

NT Event ID: 1179 (Hex)0x8435049b (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: External Array Controller Active.

Log Message: The external controller in I/O slot %5 of array “%4” has become the active controller.

SNMP Trap: cpqFcaCntlrActive - 16014 in CPQFCA.MIB

Symptom: Fibre Array Controller Active. This trap indicates that the Storage Agent has detected that a backup array controller in a duplexed pair has switched over to the active role. The variable cpqFcaCntlrBoxIoSlot indicates the new active controller index.

User Action: Check the partner controller for problems. If this was the result of a user initiated switch-over, no action is required.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqFcaCntlrBoxIoSlot

Supporting SNMP Trap Description: “Controller in I/O slot [cpqFcaCntlrBoxIoSlot] is now active on chassis [cpqSsChassisName].”

NT Event ID: 1180 (Hex)0x8435049c (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Tape Library Status Change.

Log Message: The tape library in slot %4, SCSI bus %5, SCSI target %6 has a new status of %7

SNMP Trap: cpqDa2TapeLibraryStatusChange - 3031 in CPQIDA.MIB

Symptom: Tape Library Status Change. This trap indicates that the agent has detected a change in the status of a tape library. The variable cpqDaTapeLibraryStatus indicates the current tape library status. The variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library.

User Action: If the tape library is failed, check the tape library front panel.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaTapeLibraryCntlrIndex
  • cpqDaTapeLibraryScsiBus
  • cpqDaTapeLibraryScsiTarget
  • cpqDaTapeLibraryScsiLun
  • cpqDaTapeLibraryModel
  • cpqDaTapeLibraryFWRev
  • cpqDaTapeLibrarySerialNumber
  • cpqDaTapeLibraryStatus

Supporting SNMP Trap Description: “Status is now [cpqDaTapeLibraryStatus] for the tape library.”

NT Event ID: 1181 (Hex)0x8435049d (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Tape Library Door Status Change.

Log Message: The tape library in slot %4, SCSI bus %5, SCSI target %6 has a new door status of %7.

SNMP Trap: cpqDaTapeLibraryDoorStatusChange - 3021 in CPQIDA.MIB

Symptom: Tape Library Door Status Change. This trap indicates that the agent has detected a change in the door status of a tape library. The variable cpqDaTapeLibraryDoorStatus indicates the current tape library door status. The variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library.

User Action: If the tape library door is open, close the tape library door.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaTapeLibraryCntlrIndex
  • cpqDaTapeLibraryScsiBus
  • cpqDaTapeLibraryScsiTarget
  • cpqDaTapeLibraryScsiLun
  • cpqDaTapeLibraryDoorStatus

Supporting SNMP Trap Description: “The door is [cpqDaTapeLibraryDoorStatus] for tape library.”

NT Event ID: 1182 (Hex)0x8435049e (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Tape Drive Status Change.

Log Message: The tape drive in slot %4, SCSI bus %5, SCSI target %6 has a new status of %7.

SNMP Trap: cpqDa2TapeDriveStatusChange - 3032 in CPQIDA.MIB

Symptom: Tape Drive Status Change. This trap indicates that the agent has detected a change in the status of a tape drive. The variable cpqDaTapeDrvStatus indicates the current tape status. The variable cpqDaTapeDrvScsiIdIndex indicates the SCSI ID of the tape drive.

User Action: If the tape is failed, check the tape and all SCSI connections.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaTapeDrvCntlrIndex
  • cpqDaTapeDrvBusIndex
  • cpqDaTapeDrvScsiIdIndex
  • cpqDaTapeDrvLunIndex
  • cpqDaTapeDrvName
  • cpqDaTapeDrvFwRev
  • cpqDaTapeDrvSerialNumber
  • cpqDaTapeDrvStatus

Supporting SNMP Trap Description: “Status is now [cpqDaTapeDrvStatus] for a tape drive.”

NT Event ID: 1183 (Hex)0x8435049f (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Tape Drive Cleaning Required.

Log Message: The tape drive in slot %4, SCSI bus %5, SCSI target %6 requires cleaning.

SNMP Trap: cpqDaTapeDriveCleaningRequired - 3023 in CPQIDA.MIB

Symptom: Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have a cleaning tape inserted and run. This causes the tape drive heads to be cleaned.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaTapeDrvCntlrIndex
  • cpqDaTapeDrvBusIndex
  • cpqDaTapeDrvScsiIdIndex
  • cpqDaTapeDrvLunIndex

Supporting SNMP Trap Description: “Cleaning is needed for the tape drive.”

NT Event ID: 1184 (Hex)0x843504a0 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Tape Drive Replace Cleaning Tape.

Log Message: The cleaning tape in the tape drive in slot %4, SCSI bus %5, SCSI target %6 needs to be replaced.

SNMP Trap: cpqDaTapeDriveCleanTapeReplace - 3024 in CPQIDA.MIB

Symptom: Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new cleaning tape.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaTapeDrvCntlrIndex
  • cpqDaTapeDrvBusIndex
  • cpqDaTapeDrvScsiIdIndex
  • cpqDaTapeDrvLunIndex

Supporting SNMP Trap Description: “Cleaning tape needs replacing.”

NT Event ID: 1185 (Hex)0x843504a1 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Fibre Channel Controller Status Change.

Log Message: The Fibre Channel Controller in slot %4 has a new status of %5.

SNMP Trap: cpqFca2HostCntlrStatusChange - 16021 in CPQFCA.MIB

Symptom: Fibre Channel Host Controller Status Change. This trap indicates that the agent has detected a change in the status of a Fibre Channel Host Controller. The variable cpqFcaHostCntlrStatus indicates the current controller status.

User Action: If the controller status is failed, replace the controller.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqFcaHostCntlrSlot
  • cpqFcaHostCntlrStatus
  • cpqFcaHostCntlrModel
  • cpqFcaHostCntlrWorldWideName

Supporting SNMP Trap Description: “Host controller in slot [cpqFcaHostCntlrSlot] has a new status of [cpqFcaHostCntlrStatus].”

NT Event ID: 1186 (Hex)0x843504a2 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: IDE ATA Disk Status Change.

Log Message: The ATA disk drive with model %6 and serial number %7 has a new status of %2.

SNMP Trap: cpqIdeAtaDiskStatusChange - 14004 in CPQIDE.MIB

Symptom: ATA Disk Status Change. This trap indicates that the agent has detected a change in the status of an ATA disk drive. The variable cpqIdeAtaDiskStatus indicates the current disk drive status.

User Action: If the physical drive status is smartError(3), failed(4) or ssdWearOut(5) replace the drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqIdeAtaDiskControllerIndex
  • cpqIdeAtaDiskIndex
  • cpqIdeAtaDiskModel
  • cpqIdeAtaDiskFwRev
  • cpqIdeAtaDiskSerialNumber
  • cpqIdeAtaDiskStatus
  • cpqIdeAtaDiskChannel
  • cpqIdeAtaDiskNumber

Supporting SNMP Trap Description: “Status is now [cpqIdeAtaDiskStatus] for the ATA disk.”

NT Event ID: 1187 (Hex)0x843504a3 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: ATA RAID Logical Drive Status Change.

Log Message: ATA RAID logical drive number %6 on the “%5” in slot %4 has a new status of %2.

SNMP Trap: cpqIdeLogicalDriveStatusChange - 14005 in CPQIDE.MIB

Symptom: IDE Logical Drive Status Change. This trap indicates that the agent has detected a change in the status of an IDE logical drive. The variable cpqIdeLogicalDriveStatus indicates the current logical drive status.

User Action: If the logical drive status is failed(5), examine the array for failed drives that need replacement.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqIdeControllerModel
  • cpqIdeControllerSlot
  • cpqIdeLogicalDriveControllerIndex
  • cpqIdeLogicalDriveIndex
  • cpqIdeLogicalDriveStatus

Supporting SNMP Trap Description: “Status is now [cpqIdeLogicalDriveStatus] for the IDE logical drive.”

NT Event ID: 1188 (Hex)0x843504a4 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Fan Status Change.

Log Message: An enclosure attached to port %5 of storage system “%4” has a new fan status of %7. The enclosure model is “%6”.

SNMP Trap: cpqSsExBackplaneFanStatusChange - 8022 in CPQSTSYS.MIB

Symptom: Storage System Fan Status Change. The agent has detected a change in the fan status of a storage system. The variable cpqSsBackplaneFanStatus indicates the current fan status.

User Action: If the fan status is degraded or failed, replace any failed fans.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqSsBackplaneIndex
  • cpqSsBackplaneVendor
  • cpqSsBackplaneModel
  • cpqSsBackplaneSerialNumber
  • cpqSsBackplaneFanStatus

Supporting SNMP Trap Description: “Storage system fan status changed to [cpqSsBackplaneFanStatus].”

NT Event ID: 1189 (Hex)0x843504a5 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Temperature Status Change.

Log Message: An enclosure attached to port %5 of storage system “%4” has a new temperature status of %7. The enclosure model is “%6”.

SNMP Trap: cpqSsExBackplaneTempStatusChange - 8023 in CPQSTSYS.MIB

Symptom: Storage System Temperature Status Change. The agent has detected a change in the status of the temperature in a storage system. The variable cpqSsBackplaneTempStatus indicates the current status.

User Action: If the temperature status is degraded or failed, shut down the storage system as soon as possible. Be sure that the storage system environment is being cooled properly and that no components are overheated.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqSsBackplaneIndex
  • cpqSsBackplaneVendor
  • cpqSsBackplaneModel
  • cpqSsBackplaneSerialNumber
  • cpqSsBackplaneTempStatus

Supporting SNMP Trap Description: “Storage system temperature status changed to [cpqSsBackplaneTempStatus].”

NT Event ID: 1190 (Hex)0x843504a6 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Power Supply Status Change.

Log Message: An enclosure attached to port %5 of storage system “%4” has a new power supply status of %7. The enclosure model is “%6”.

SNMP Trap: cpqSsExBackplanePowerSupplyStatusChange - 8024 in CPQSTSYS.MIB

Symptom: Storage System Power Supply Status Change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBackplaneFtpsStatus indicates the current status.

User Action: If the power supply status is degraded, restore power or replace the failed power supply.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqSsBackplaneIndex
  • cpqSsBackplaneVendor
  • cpqSsBackplaneModel
  • cpqSsBackplaneSerialNumber
  • cpqSsBackplaneFtpsStatus

Supporting SNMP Trap Description: “Storage system power supply status changed to [cpqSsBackplaneFtpsStatus].”

NT Event ID: 1191 (Hex)0x843504a7 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: SCSI Tape Library Status Change.

Log Message: The tape library with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a new status of %7.

SNMP Trap: cpqTapeLibraryStatusChange - 5018 in CPQSCSI.MIB

Symptom: Tape Library Status Change. The Storage Agent has detected a change in the status of a tape library. The current tape library status is indicated in the cpqTapeLibraryState variable.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqTapeLibraryCntlrIndex
  • cpqTapeLibraryBusIndex
  • cpqTapeLibraryScsiIdIndex
  • cpqTapeLibraryLunIndex
  • cpqTapeLibraryName
  • cpqTapeLibraryFwRev
  • cpqTapeLibrarySerialNumber
  • cpqTapeLibraryState

Supporting SNMP Trap Description: “Status is now [cpqTapeLibraryState].”

NT Event ID: 1192 (Hex)0x843504a8 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: SCSI Tape Drive Status Change.

Log Message: The tape drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has a new status of %2.

SNMP Trap: cpqTape5PhyDrvStatusChange - 5019 in CPQSCSI.MIB

Symptom: Tape Drive Status Change. The Storage Agent has detected a change in the status of a tape drive. The current physical drive status is indicated in the cpqTapePhyDrvStatus variable.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqTapePhyDrvCntlrIndex
  • cpqTapePhyDrvBusIndex
  • cpqTapePhyDrvScsiIdIndex
  • cpqTapePhyDrvLunIndex
  • cpqTapePhyDrvName
  • cpqTapePhyDrvFwRev
  • cpqTapePhyDrvSerialNumber
  • cpqTapePhyDrvStatus

Supporting SNMP Trap Description: “Status is now [cpqTapePhyDrvStatus].”

NT Event ID: 1193 (Hex)0x843504a9 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: External Tape Drive Status Change.

Log Message: The tape drive at location “%4”, has a new status of %7.

SNMP Trap: cpqExtTapeDriveStatusChange - 16023 in CPQFCA.MIB

Symptom: External Tape Drive Status Change. This trap indicates that the agent has detected a change in the status of an External Tape Drive. The variable cpqFcTapeDriveStatus indicates the current tape status.

User Action: If the tape is failed or is offline, check the tape and all connections.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqFcTapeDriveCntlrIndex
  • cpqFcTapeDriveScsiBus
  • cpqFcTapeDriveScsiTarget
  • cpqFcTapeDriveScsiLun
  • cpqFcTapeDriveModel
  • cpqFcTapeDriveFWRev
  • cpqFcTapeDriveSerialNumber
  • cpqFcTapeDriveLocation
  • cpqFcTapeDriveStatus

Supporting SNMP Trap Description: “Status is now [cpqFcTapeDriveStatus] for a tape drive.”

NT Event ID: 1194 (Hex)0x843504aa (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: External Tape Drive Cleaning Required.

Log Message: The tape drive at location “%4” requires cleaning.

SNMP Trap: cpqExtTapeDriveCleaningRequired - 16024 in CPQFCA.MIB

Symptom: External Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have a cleaning tape inserted and run. This causes the tape drive heads to be cleaned.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqFcTapeDriveCntlrIndex
  • cpqFcTapeDriveScsiBus
  • cpqFcTapeDriveScsiTarget
  • cpqFcTapeDriveScsiLun
  • cpqFcTapeDriveModel
  • cpqFcTapeDriveFWRev
  • cpqFcTapeDriveSerialNumber
  • cpqFcTapeDriveLocation

Supporting SNMP Trap Description: “Cleaning is needed for tape drive.”

NT Event ID: 1195 (Hex)0x843504ab (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: External Tape Drive Replace Cleaning Tape.

Log Message: The cleaning tape in the tape drive at location “%4” needs to be replaced.

SNMP Trap: cpqExtTapeDriveCleanTapeReplace - 16025 in CPQFCA.MIB

Symptom: External Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new cleaning tape.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqFcTapeDriveCntlrIndex
  • cpqFcTapeDriveScsiBus
  • cpqFcTapeDriveScsiTarget
  • cpqFcTapeDriveScsiLun
  • cpqFcTapeDriveModel
  • cpqFcTapeDriveFWRev
  • cpqFcTapeDriveSerialNumber
  • cpqFcTapeDriveLocation

Supporting SNMP Trap Description: “Cleaning tape needs replacing.”

NT Event ID: 1196 (Hex)0x843504ac (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Recovery Server Option Status Change.

Log Message: Storage system “%4” has a new RSO status of %5.

SNMP Trap: cpqSsExRecoveryServerStatusChange - 8025 in CPQSTSYS.MIB

Symptom: Storage System Recovery Server Option Status Change. The agent has detected a change in the recovery server option status of a storage system. The variable cpqSsChassisRsoStatus indicates the current status.

User Action: If the RSO status is noSecondary(6) or linkDown(7), Be sure that the secondary server is operational and that all cables are connected properly. If the RSO status is secondaryRunningAuto(8) or secondaryRunningUser(9), examine the primary server for failed components.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsChassisName
  • cpqSsChassisTime
  • cpqSsChassisRsoStatus
  • cpqSsChassisIndex

Supporting SNMP Trap Description: “Storage system recovery server option status changed to [cpqSsChassisRsoStatus].”

NT Event ID: 1197 (Hex)0x843504ad (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: External Tape Library Status Change.

Log Message: The tape library at location “%4”, has a new status of %7.

SNMP Trap: cpqExtTapeLibraryStatusChange - 16026 in CPQFCA.MIB

Symptom: External Tape Library Status Change. This trap indicates that the agent has detected a change in the status of an External Tape library. The variable cpqFcTapeLibraryStatus indicates the current tape library status.

User Action: If the tape library is failed or is offline, check the tape library front panel and all connections.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqFcTapeLibraryCntlrIndex
  • cpqFcTapeLibraryScsiBus
  • cpqFcTapeLibraryScsiTarget
  • cpqFcTapeLibraryScsiLun
  • cpqFcTapeLibraryModel
  • cpqFcTapeLibraryFWRev
  • cpqFcTapeLibrarySerialNumber
  • cpqFcTapeLibraryLocation
  • cpqFcTapeLibraryStatus

Supporting SNMP Trap Description: “Status is now [cpqFcTapeLibraryStatus] for the tape library.”

NT Event ID: 1198 (Hex)0x843504ae (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: External Tape Library Door Status Change.

Log Message: The tape library at location “%4”, has a new door status of %7.

SNMP Trap: cpqExtTapeLibraryDoorStatusChange - 16027 in CPQFCA.MIB

Symptom: External Tape Library Door Status Change. This trap indicates that the agent has detected a change in the door status of an External Tape library. The variable cpqFcTapeLibraryDoorStatus indicates the current tape library door status.

User Action: If the tape library door is open, close the tape library door.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqFcTapeLibraryCntlrIndex
  • cpqFcTapeLibraryScsiBus
  • cpqFcTapeLibraryScsiTarget
  • cpqFcTapeLibraryScsiLun
  • cpqFcTapeLibraryModel
  • cpqFcTapeLibraryFWRev
  • cpqFcTapeLibrarySerialNumber
  • cpqFcTapeLibraryLocation
  • cpqFcTapeLibraryDoorStatus

Supporting SNMP Trap Description: “The door is [cpqFcTapeLibraryDoorStatus] for tape library.”

NT Event ID: 1199 (Hex)0x843504af (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Controller Status Change.

Log Message: The Drive Array Controller in %7 has a new status of %5.

SNMP Trap: cpqDa6CntlrStatusChange - 3033 in CPQIDA.MIB

Symptom: Controller Status Change. This trap indicates that the agent has detected a change in the status of a drive array controller. The variable cpqDaCntlrBoardStatus indicates the current controller status.

User Action: If the board status is generalFailure(3), you may need to replace the controller. If the board status is cableProblem(4), check the cable connections between the controller and the storage system.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaCntlrIndex
  • cpqDaCntlrBoardStatus
  • cpqDaCntlrModel
  • cpqDaCntlrSerialNumber
  • cpqDaCntlrFWRev
  • cpqDaAccelTotalMemory

Supporting SNMP Trap Description: “Status is now [cpqDaCntlrBoardStatus].”