329-Power Management Controller FW Error

Symptom

329-Power Management Controller FW Error – Unable to communicate with the FW. Action: Reset iLO FW. If issue persists reset the Power Management Controller FW (remove AC). If issue persists attempt to update the FW.

Cause

A communication issue exists within iLO or the power management controller firmware.

Action
  1. Reset the iLO firmware.

    For more information, see the iLO user guide on the Hewlett Packard Enterprise website.

  2. If the issue persists, reset the power management controller firmware by removing AC power.
  3. If the issue persists, update the power management controller firmware.

    For more information, see "Keeping the system current" in the HPE ProLiant Gen9 Troubleshooting Guide, Volume I on the Hewlett Packard Enterprise website.