1787-Slot X Drive Array Operating in Interim Recovery (Degraded) Mode
1787-Slot X Drive Array Operating in Interim Recovery (Degraded) Mode.
(Followed by one or more of the following:)
- The following disk drive(s) are failed and should be replaced
- The following disk drive(s) are insufficient size and should be replaced
- The following disk drive(s) are mismatched type and should be replaced
- The following disk drive(s) are unsupported type and should be replaced
- The following disk drive(s) are offline due to the erase process
(Additionally followed by one of the following if a spare drive is activated:)
- On-Line Spare Drive is being Activated
- On-Line Spare Drive Active
- On-Line Spare Drive Failed
- The drive has failed.
- The drives are of insufficient size.
- The drives are of different types.
- The drives are not supported.
- The drives are offline.
- A cable is not installed correctly.
- A cable has failed.
Following a system restart, this message notes that the drive is defective and the logical drive might not be fault tolerant and may fail if another physical drive fails.