Message identifiers 24650-24674

Message Id: 24650

Severity: Informational

Log message: SnapShot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has been created.

<external specification> values:

  • the external controller attached to
  • ""

Message Id: 24651

Severity: Error

Log message: SnapShot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> failed and has been deleted.

<external specification> values:

  • the external controller attached to
  • ""

Message Id: 24652

Severity: Informational

Log message:SnapShot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has been restored.

<external specification> values:

  • the external controller attached to
  • ""

Message Id: 24653

Severity: Informational

Log message: SnapShot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has been detached.

<external specification> values:

  • the external controller attached to
  • ""

Message Id: 24654

Severity: Informational

Log message: SnapShot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has been deleted.

<external specification> values:

  • the external controller attached to
  • ""

Message Id: 24655

Severity: Error

Log message: Restore operation of SnapShot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> failed due to possible data corruption.

<external specification> values:

  • the external controller attached to
  • ""

Message Id: 24656

Severity: Warning

Log message: SnapShot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has been disabled.

<external specification> values:

  • the external controller attached to
  • ""

Message Id: 24657

Severity: Informational

Log message: Performing a recovery for a restore operation on SnapShot ID <ID number> for logical drive <logical drive number> on <external specification> array controller <controller name / slot information>.

<external specification> values:

  • the external controller attached to
  • ""

Message Id: 24658

Severity: Informational

Log message: Restore operation started on Snapshot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information>.

<external specification> values:

  • the external controller attached to
  • ""

Message Id: 24659

Severity: Informational

Log message: Port <port number> of controller <controller name / slot information> is reporting <PHY status> for PHY number <phy number>.

Message Id: 24660

Severity: Informational

Log message: Smart Array controller <controller name / slot information> has reported that its partner controller has been <added to / removed from> the SAS fabric.

Message Id: 24661

Severity: Informational

Log message: Surface analysis parity/consistency initialization forced complete for logical drive <logical drive number> on Smart Array controller <controller name / slot information>.

Message Id: 24662

Severity: Informational

Log message: Smart Array controller <controller name / slot information> has reported that <number of passes> surface analysis passes have completed for logical drive <logical drive number>.

Message Id: 24668

Severity: Informational

Log message: SnapShot resource volume of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> is okay.

<external specification> values:

  • the external controller attached to
  • ""

Message Id: 24669

Severity: Warning

Log message: Snapshot resource volume of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> is approaching its limit.

<external specification> values:

  • the external controller attached to
  • ""

Message Id: 24670

Severity: Error

Log message: Snapshot resource volume of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has failed.

<external specification> values:

  • the external controller attached to
  • ""

Message Id: 24671

Severity: Informational

Log message: Snapshot resource volume of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has been deleted.

<external specification> values:

  • the external controller attached to
  • ""

Message Id: 24672

Severity: Error

Log message: Snapshot resource volume of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has reached its limit.

<external specification> values:

  • the external controller attached to
  • ""

Message Id: 24673

Severity: Informational

Log message: Power supply number <power supply number> was <inserted / removed>. This power supply is located in the storage chassis with serial number <serial number> which is attached to port <port number> of array controller <controller name / slot information>.

Message Id: 24674

Severity: Warning

Log message: Array controller <controller name / slot information> is reporting inconsistent data that was previously consistent.<additional data> The inconsistent data may be caused by a power loss during write activity or by a drive returning corrupt data. The inconsistent data is between block address <block address 1> and block address <block address 2> of logical drive <logical drive number>.

<additional data> values:

  • The parity data does not match the data drives.
  • “”