Message identifiers 24650-24674
Message Id: 24650
Severity: Informational
Log message: SnapShot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has been created.
<external specification> values:
- “
the external controller attached to
” - ""
Message Id: 24651
Severity: Error
Log message: SnapShot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> failed and has been deleted.
<external specification> values:
- “
the external controller attached to
” - ""
Message Id: 24652
Severity: Informational
Log message:SnapShot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has been restored.
<external specification> values:
- “
the external controller attached to
” - ""
Message Id: 24653
Severity: Informational
Log message: SnapShot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has been detached.
<external specification> values:
- “
the external controller attached to
” - ""
Message Id: 24654
Severity: Informational
Log message: SnapShot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has been deleted.
<external specification> values:
- “
the external controller attached to
” - ""
Message Id: 24655
Severity: Error
Log message: Restore operation of SnapShot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> failed due to possible data corruption.
<external specification> values:
- “
the external controller attached to
” - ""
Message Id: 24656
Severity: Warning
Log message: SnapShot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has been disabled.
<external specification> values:
- “
the external controller attached to
” - ""
Message Id: 24657
Severity: Informational
Log message: Performing a recovery for a restore operation on SnapShot ID <ID number> for logical drive <logical drive number> on <external specification> array controller <controller name / slot information>.
<external specification> values:
- “
the external controller attached to
” - ""
Message Id: 24658
Severity: Informational
Log message: Restore operation started on Snapshot ID <ID number> of logical drive <logical drive number> on <external specification> array controller <controller name / slot information>.
<external specification> values:
- “
the external controller attached to
” - ""
Message Id: 24659
Severity: Informational
Log message: Port <port number> of controller <controller name / slot information> is reporting <PHY status> for PHY number <phy number>.
Message Id: 24660
Severity: Informational
Log message: Smart Array controller <controller name / slot information> has reported that its partner controller has been <added to / removed from> the SAS fabric.
Message Id: 24661
Severity: Informational
Log message: Surface analysis parity/consistency initialization forced complete for logical drive <logical drive number> on Smart Array controller <controller name / slot information>.
Message Id: 24662
Severity: Informational
Log message: Smart Array controller <controller name / slot information> has reported that <number of passes> surface analysis passes have completed for logical drive <logical drive number>.
Message Id: 24668
Severity: Informational
Log message: SnapShot resource volume of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> is okay.
<external specification> values:
- “
the external controller attached to
” - ""
Message Id: 24669
Severity: Warning
Log message: Snapshot resource volume of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> is approaching its limit.
<external specification> values:
- “
the external controller attached to
” - ""
Message Id: 24670
Severity: Error
Log message: Snapshot resource volume of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has failed.
<external specification> values:
- “
the external controller attached to
” - ""
Message Id: 24671
Severity: Informational
Log message: Snapshot resource volume of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has been deleted.
<external specification> values:
- “
the external controller attached to
” - ""
Message Id: 24672
Severity: Error
Log message: Snapshot resource volume of logical drive <logical drive number> on <external specification> array controller <controller name / slot information> has reached its limit.
<external specification> values:
- “
the external controller attached to
” - ""
Message Id: 24673
Severity: Informational
Log message: Power supply number <power supply number> was <inserted / removed>. This power supply is located in the storage chassis with serial number <serial number> which is attached to port <port number> of array controller <controller name / slot information>.
Message Id: 24674
Severity: Warning
Log message: Array controller <controller name / slot information> is reporting inconsistent data that was previously consistent.<additional data> The inconsistent data may be caused by a power loss during write activity or by a drive returning corrupt data. The inconsistent data is between block address <block address 1> and block address <block address 2> of logical drive <logical drive number>.
<additional data> values:
- “
The parity data does not match the data drives.
“ - “”