Event Identifiers 1025-1092

NT Event ID: 1025 (Hex)0x84350401 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Advanced Memory Protection subsystem has detected a memory fault. The Online Spare Memory has been activated. Schedule server down time to replace the memory.

SNMP Trap: cpqHeResilientMemOnlineSpareEngaged - 6047 in CPQHLTH.MIB

Symptom: Advanced Memory Protection Online Spare Engaged. The Advanced Memory Protection subsystem has detected a memory fault. The Online Spare Memory has been activated.

User Action: Schedule server down time to replace the faulty memory.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “The Advanced Memory Protection subsystem has engaged the online spare memory.”

NT Event ID: 1026 (Hex)0x84350402 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Advanced Memory Protection sub-system has detected a memory fault. The Mirrored Memory has been activated. Schedule server down time to replace the memory.

SNMP Trap: cpqHeResilientMemMirroredMemoryEngaged - 6051 in CPQHLTH.MIB

Symptom: Advanced Memory Protection Mirrored Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. Mirrored Memory has been activated.

User Action: Replace the faulty memory.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “The Advanced Memory Protection subsystem has engaged the online spare memory.”

NT Event ID: 1027 (Hex)0x84350403 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Advanced Memory Protection sub-system has detected a memory fault. Advanced ECC has been activated. Schedule server down time to replace the memory.

SNMP Trap: cpqHeResilientAdvancedECCMemoryEngaged - 6052 in CPQHLTH.MIB

Symptom: Advanced Memory Protection Advanced ECC Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. Advanced ECC has been activated.

User Action: Replace the faulty memory.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “The Advanced Memory Protection subsystem has engaged the advanced ECC memory.”

NT Event ID: 1028 (Hex)0x84350404 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Advanced Memory Protection sub-system has detected a memory fault. The XOR recovery engine has been activated. Schedule server down time to replace the memory.

SNMP Trap: cpqHeResilientMemXorMemoryEngaged - 6053 in CPQHLTH.MIB

Symptom: Advanced Memory Protection XOR Engine Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. The XOR engine has been activated.

User Action: Replace the faulty memory.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “The Advanced Memory Protection subsystem has engaged the XOR memory.”

NT Event ID: 1029 (Hex)0x44350405 (cpqsvmsg.dll)

Log Severity: Information (1)

Log Message: The Fault Tolerant Power Supply Sub-system has returned to a redundant state.

SNMP Trap: cpqHe3FltTolPowerRedundancyRestored - 6054 in CPQHLTH.MIB

Symptom: The Fault Tolerant Power Supplies have returned to a redundant state for the specified chassis.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeFltTolPowerSupplyChassis

Supporting SNMP Trap Description: “The Power Supplies are now redundant on Chassis [cpqHeFltTolPowerSupplyChassis].”

NT Event ID: 1030 (Hex) 0x44350406 (cpqsvmsg.dll)

Log Severity: Information (1)

Log Message: The Fan Sub-system has returned to a redundant state.

SNMP Trap: cpqHe3FltTolFanRedundancyRestored - 6055 in CPQHLTH.MIB

Symptom: The Fault Tolerant Fans have returned to a redundant state for the specified chassis.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeFltTolFanChassis

Supporting SNMP Trap Description: “The Fans are now redundant on Chassis [cpqHeFltTolFanChassis].”

NT Event ID: 1035 (Hex) 0x8435040BL (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: Corrected/uncorrected memory errors detected. The errors have been corrected, but the memory module should be replaced. Value 0 for CPU means memory is not Processor based.

SNMP Trap: cpqHe5CorrMemReplaceMemModule - 6064 in CPQHLTH.MIB

Symptom: Corrected Memory Errors Detected. The errors have been corrected, but the memory module should be replaced. Value 0 for CPU means memory is not processor-based.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeResMem2BoardNum
  • cpqHeResMem2CpuNum
  • cpqHeResMem2RiserNum
  • cpqHeResMem2ModuleNum
  • cpqHeResMem2ModulePartNo
  • cpqHeResMem2ModuleSize
  • cpqSiServerSystemId

Supporting SNMP Trap Description: “Correctable memory errors require a replacement of the memory module in slot [cpqHeResMem2BoardNum], socket [cpqHeResMem2ModuleNum], Cpu [cpqHeResMem2CpuNum] Riser [cpqHeResMem2RiserNum].” Correctable/uncorrectable memory errors require a replacement of the memory module in slot [cpqHeResMem2BoardNum]], cpu [cpqHeResMem2CpuNum], riser [cpqHeResMem2RiserNum], socket [cpqHeResMem2ModuleNum].

NT Event ID: 1036 (Hex) 0x4435040CL (cpqsvmsg.dll)

Log Severity: Informational (1)

Log Message: A memory board or cartridge has been removed from the system. Please reinsert the memory board or cartridge.

SNMP Trap: cpqHe5ResMemBoardRemoved - 6065 in CPQHLTH.MIB

Symptom: Memory board or cartridge or riser removed. An Advanced Memory Protection sub-system board or cartridge or riser has been removed from the system. Value 0 for CPU means memory is not processor-based.

User Action: Be sure that the board, cartridge, or riser memory is installed correctly, and then re-install the memory board, cartridge, or processor.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeResMem2BoardSlotNum
  • cpqHeResMem2BoardCpuNum
  • cpqHeResMem2BoardRiserNum

Supporting SNMP Trap Description: “Memory Board or Cartridge Removed from Slot [cpqHeResMem2BoardSlotNum], Cpu [cpqHeResMem2BoardCpuNum], Riser [cpqHeResMem2BoardRiserNum].”

NT Event ID: 1037 (Hex) 0x4435040DL (cpqsvmsg.dll)

Log Severity: Informational (1)

Log Message: System Information Agent: Health: A memory board or cartridge has been inserted into the system.

SNMP Trap: cpqHe5ResMemBoardInserted - 6066 in CPQHLTH.MIB

Symptom: Memory board or cartridge or riser inserted. An Advanced Memory Protection sub-system board, cartridge, or riser has been installed. Value 0 for CPU means memory is not processor-based.

User Action: None.

SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeResMem2BoardSlotNum
  • cpqHeResMem2BoardCpuNum
  • cpqHeResMem2BoardRiserNum

Supporting SNMP Trap Description: “Memory Board or Cartridge Inserted into Slot [cpqHeResMem2BoardSlotNum], Cpu[cpqHeResMem2BoardCpuNum], Riser[cpqHeResMem2BoardRiserNum].”

NT Event ID: 1038 (Hex) 0xC435040EL (cpqsvmsg.dll)

Log Severity: Error (3)

Log Message: A memory board or cartridge bus error has been detected in the memory subsystem.

SNMP Trap: cpqHe5ResMemBoardBusError- 6067 in CPQHLTH.MIB

Symptom: Memory board, cartridge, or riser bus error detected. An Advanced Memory Protection sub-system board, cartridge, or riser bus error has been detected. Value 0 for CPU means memory is not processor-based.

User Action: Replace the indicated board or cartridge or Riser.

SNMP Trap Data:

  • sysName,
  • cpqHoTrapFlags
  • cpqHeResMem2BoardSlotNum
  • cpqHeResMem2BoardCpuNum
  • cpqHeResMem2BoardRiserNum

Supporting SNMP Trap Description: “Memory Board or Cartridge Inserted into Slot [cpqHeResMem2BoardSlotNum], Cpu[cpqHeResMem2BoardCpuNum], Riser[cpqHeResMem2BoardRiserNum].”

NT Event ID: 1039 (Hex) 0x8435040FL (cpqsvmsg.dll)

Log Severity: Warning (3)

Log Message: The Advanced Memory Protection sub-system has detected a memory fault. The LockStep recovery engine has been activated. For instruction on replacing the faulty memory, see the server documentation.

SNMP Trap: cpqHeResilientMemLockStepMemoryEngaged - 6068 in CPQHLTH.MIB

Symptom: Advanced Memory Protection LockStep Engine Memory Engaged. The Advanced Memory Protection subsystem has detected a memory fault. The LockStep engine has been activated.

User Action: Replace the faulty memory.

Supporting SNMP Trap Data:

  • sysName,
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “The Advanced Memory Protection subsystem has engaged the LockStep memory.”

NT Event ID: 1040 (Hex) 0xC43504A0L (cpqsvmsg.dll)

Log Severity: Warning (3)

Log Message: The fault tolerant power supply AC power loss for the specified chassis and bay location.

SNMP Trap: cpqHeResilientMemLockStepMemoryEngaged - 6069 in CPQHLTH.MIB

Symptom: The fault tolerant power supply AC power loss for the specified chassis and bay location.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeFltTolPowerSupplyChassis
  • cpqHeFltTolPowerSupplyBay
  • cpqHeFltTolPowerSupplyStatus
  • cpqHeFltTolPowerSupplyModel
  • cpqHeFltTolPowerSupplySerialNumber
  • cpqHeFltTolPowerSupplyAutoRev
  • cpqHeFltTolPowerSupplyFirmwareRev
  • cpqHeFltTolPowerSupplySparePartNum
  • cpqSiServerSystemId

Supporting SNMP Trap Description: “The Power Supply AC power loss in [sysName], Bay [cpqHeFltTolPowerSupplyBay], Status [cpqHeFltTolPowerSupplyStatus], Model [cpqHeFltTolPowerSupplyModel], Serial Num [cpqHeFltTolPowerSupplySerialNumber], Firmware [cpqHeFltTolPowerSupplyFirmwareRev].”

NT Event ID: 1072 (Hex)0x84350430 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The frequency of memory errors is high enough such that tracking of correctable memory errors has been temporarily disabled.

SNMP Trap: cpqHe3CorrectableMemoryLogDisabled - 6016 in CPQHLTH.MIB

Symptom: Correctable memory error tracking disabled. The frequency of errors is so high that the error tracking logic has been temporarily disabled. The cpqHeCorrMemLogStatus variable indicated the current tracking status.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeCorrMemLogStatus

Supporting SNMP Trap Description: “Too many memory errors - tracking now disabled.”

NT Event ID: 1082 (Hex)0xc435043a (cpqsvmsg.dll)

Log Severity: Error (3)

Log Message: A Thermal Temperature Condition has been set to failed. The system will be shut down due to this thermal condition.

SNMP Trap: cpqHe3ThermalTempFailed - 6017 in CPQHLTH.MIB

Symptom: The temperature status has been set to failed. The system is shut down due to this thermal condition.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “System will be shut down due to this thermal condition.”

NT Event ID: 1083 (Hex)0x8435043b (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: The Thermal Temperature Condition has been set to degraded. The system may be shut down due to this thermal condition depending on the state of the thermal degraded action value '%4'.

SNMP Trap: cpqHe3ThermalTempDegraded - 6018 in CPQHLTH.MIB

Symptom: The temperature status has been set to degraded. The server's temperature is outside of the normal operating range. The server is shut down if the cpqHeThermalDegradedAction variable is set to shutdown (3).

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeThermalDegradedAction

Supporting SNMP Trap Description: “Temperature out of range. Shutdown may occur.”

NT Event ID: 1084 (Hex)0x4435043c (cpqsvmsg.dll)

Log Severity: Information (1)

Log Message: The Thermal Temperature Condition has been set to OK. The server's temperature has returned to its normal operating range.

SNMP Trap: cpqHe3ThermalTempOk - 6019 in CPQHLTH.MIB

Symptom: The temperature status has been set to OK. The server's temperature has returned to the normal operating range.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “Temperature has returned to normal range.”

NT Event ID: 1085 (Hex)0xc435043d (cpqsvmsg.dll)

Log Severity: Error (3)

Log Message: A System Fan Condition has been set to failed. The system may be shut down due to this thermal condition.

SNMP Trap: cpqHe3ThermalSystemFanFailed - 6020 in CPQHLTH.MIB

Symptom: The system fan status has been set to failed. A required system fan is not operating normally. The system is shut down if the cpqHeThermalDegradedAction variable is set to shutdown (3).

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqHeThermalDegradedAction

Supporting SNMP Trap Description: “Required fan not operating normally. Shutdown may occur.”

NT Event ID: 1086 (Hex)0x8435043e (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: A System Fan Condition has been set to degraded. If the system fan is part of a redundancy group, the system will not be shut down. If the system fan is not part of a redundancy group, the system may be shut down depending on the state of the thermal degraded action value '%4'.

SNMP Trap: cpqHe3ThermalSystemFanDegraded - 6021 in CPQHLTH.MIB

Symptom: The system fan status has been set to degraded. An optional system fan is not operating normally.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “An optional fan is not operating normally.”

NT Event ID: 1087 (Hex)0x4435043f (cpqsvmsg.dll)

Log Severity: Information (1)

Log Message: A System Fan Condition has been set to OK. The server's system fan has resumed normal operation.

SNMP Trap: cpqHe3ThermalSystemFanOk - 6022 in CPQHLTH.MIB

Symptom: The system fan status has been set to OK. Any previously non-operational system fans have returned to normal operation.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “System fan has returned to normal operation.”

NT Event ID: 1088 (Hex)0xc4350440 (cpqsvmsg.dll)

Log Severity: Error (3)

Log Message: A Processor Fan Condition has been set to failed. The system will be shut down due to this condition.

SNMP Trap: cpqHe3ThermalCpuFanFailed - 6023 in CPQHLTH.MIB

Symptom: The CPU fan status has been set to failed. A processor fan is not operating normally. The server is shut down.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “CPU fan has failed. Server will be shutdown.”

NT Event ID: 1089 (Hex)0x44350441 (cpqsvmsg.dll)

Log Severity: Information (1)

Log Message: A Processor Fan Condition has been set to OK. The server's processor fan has resumed normal operation.

SNMP Trap: cpqHe3ThermalCpuFanOk - 6024 in CPQHLTH.MIB

Symptom: The CPU fan status has been set to OK. Any previously non-operational processor fans have returned to normal operation.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “CPU fan is now OK.”

NT Event ID: 1090 (Hex)0x44350442 (cpqsvmsg.dll)

Log Severity: Information (1)

Log Message: The server is operational again. The server has previously been shut down by the Automatic Server Recovery (ASR) feature and has just become operational again.

SNMP Trap: cpqHe3AsrConfirmation - 6025 in CPQHLTH.MIB

Symptom: The server is operational again. The server has previously been shut down by the Automatic Server Recovery (ASR) feature and has just become operational again.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “Server is operational again after ASR shutdown.”

NT Event ID: 1091 (Hex)0x44350443 (cpqsvmsg.dll)

Log Severity: Information (1)

Log Message: The server is operational again. The server has previously been shut down due to a thermal anomaly and has just become operational again.

SNMP Trap: cpqHe3ThermalConfirmation - 6026 in CPQHLTH.MIB

Symptom: The server is operational again. The server has previously been shut down due to a thermal anomaly on the server and has just become operational again.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “Server is operational again after thermal shutdown.”

NT Event ID: 1092 (Hex)0x84350444 (cpqsvmsg.dll)

Log Severity: Warning (2)

Log Message: Post Errors were detected. One or more Power-On-Self-Test errors were detected during server startup.

SNMP Trap: cpqHe3PostError - 6027 in CPQHLTH.MIB

Symptom: One or more POST errors occurred. Power On Self-Test (POST) errors occur during the server restart process.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags

Supporting SNMP Trap Description: “Errors occurred during server restart.”