1715-Slot # Drive Array Controller – Memory Error(s) Occurred

Symptom

1715-Slot # Drive Array Controller – Memory Error(s) Occurred. Warning: Corrected Memory Error(s) were detected during controller memory self-test. Upgrade to the latest firmware. If the problem persists, replace the Cache Module or controller.

Cause
  • The controller firmware is outdated.

  • The cache module has failed.

  • The controller has failed.

Action
  1. Update the firmware.
    For more information, see "Firmware updates" in the HPE ProLiant Gen9 Troubleshooting Guide, Volume I on the Hewlett Packard Enterprise website.
  2. If the issue persists, replace the cache module.
  3. If the issue persists, replace the controller.
    For removal and replacement procedures, see the server maintenance and service guide on the Hewlett Packard Enterprise website.