Management log messages
Log type: LOG_EMERG, Failure type: SW
OA: Internal System Firmware Error, Rebooting.
Log type: LOG_WARNING, Failure type: HW
OA: A port mismatch was found with server blade bay [value:bladeNumber] and interconnect bay [value:slotNumber]
OA: Temperature of I/O module in slot [value:slotNumber] is at alert level
Log type: LOG_WARNING, Failure type: SW
OA: iLO in bay [value] has not responded to the previous [value:count] capping requests from the Enclosure Dynamic Power Cap.
Log type: LOG_CRIT, Failure type: HW
OA Tray firmware upgrade failed.
OA: Blade in bay [value:bladeNumber] contains an unsupported #[value] mezz card.
OA: Enclosure Status changed from [N/A/Unknown/OK/Degraded/Failed] to [N/A/Unknown/OK/Degraded/Failed].
OA: Failed to initialize key components. Please call support immediately.
OA: Fan [value] firmware upgrade failed.
OA: Interconnect [value:slotNumber] firmware upgrade failed.
OA: Interconnect [value] firmware upgrade failed.
OA: LCD fails to respond to keystrokes.
OA: LCD firmware upgrade failed.
OA: LCD not functioning properly, pausing operation for 10 seconds.
OA: LCD Status is: Failed
OA: mgmt: GPIO initialization failed.
OA: mgmt: i2c initialization failed.
OA: Mismatching I/O was detected on Blade [value:bladeNumber], interconnect [value].
OA: Mismatching I/O was detected on Blade [value:bladeNumber], Mezzanine Card [value], Port [value].
OA: Mismatching I/O was detected on Interconnect [value], Port [value].
OA: Temperature of I/O module in slot [value:slotNumber] is critical - module shut down
OA: Unsupported Device in bay #[value:bladeNumber].
OA: Unsupported IO Module in bay #[value:slotNumber].
OA: Unsupported IO Module location in bay #[value:slotNumber].
Log type: LOG_CRIT, Failure type: SW
OA: Blade [value:bladeNumber] management processor firmware upgrade failed.
OA: Error reading Fru Board Info for the LCD.
OA: Error reading Fru information for the LCD.
OA: Error reading Fru Internal Use Area for the LCD.
OA: mgmt: Failed to acquire enclosure semaphore.
Log type: LOG_CRIT, Failure type: Info
OA: Mismatching I/O condition resolved, Blade [value:bladeNumber], interconnect [value] was removed.
OA: Mismatching I/O was removed on Blade [value:bladeNumber], Mezzanine Card [value], Port [value].
OA: Mismatching I/O was removed on Interconnect [value], Port [value].
Log type: LOG_NOTICE, Failure type: HW
OA: AC Subsystem Overload - FAILED. Redundant Power: [value]W DC, Present Power [value]W AC.
OA: Blade [value:bladeNumber] Ambient Temperature Cable fault...state is CRITICAL.
OA: Blade [value:bladeNumber] Ambient Temperature Cable fault...state is DEGRADED.
OA: Blade [value:bladeNumber] Ambient Temperature caution...state is CRITICAL.
OA: Blade [value:bladeNumber] Ambient Temperature caution...state is DEGRADED.
OA: Blade [value:bladeNumber] Ambient Temperature Sensor fault...state is CRITICAL.
OA: Blade [value:bladeNumber] Ambient Temperature Sensor fault...state is DEGRADED.
OA: Blade [value:bladeNumber] cannot partner with its neighbor.
OA: Blade [value:bladeNumber] Disk Tray is Open...state is CRITICAL.
OA: Blade [value:bladeNumber] Disk Tray is Open...state is DEGRADED.
OA: Blade [value:bladeNumber] FRU memory fault...state is CRITICAL.
OA: Blade [value:bladeNumber] FRU memory fault...state is DEGRADED.
OA: Blade [value:bladeNumber] has integrated blade cross connection, Mezzanine card [value] is superfluous.
OA: Blade [value:bladeNumber] Internal Temperature caution...state is CRITICAL.
OA: Blade [value:bladeNumber] Internal Temperature caution...state is DEGRADED.
OA: Blade [value:bladeNumber] Internal Temperature Sensor fault...state is CRITICAL.
OA: Blade [value:bladeNumber] Internal Temperature Sensor fault...state is DEGRADED.
OA: Blade [value:bladeNumber] is not properly cooled.
OA: Blade [value:bladeNumber] is not supported.
OA: Blade [value:bladeNumber] is reporting degraded health status.
OA: Blade [value:bladeNumber] is reporting failed health status.
OA: Blade [value:bladeNumber] Main Logic Board fault...state is CRITICAL.
OA: Blade [value:bladeNumber] Main Logic Board fault...state is DEGRADED.
OA: Blade [value:bladeNumber] needs a partner device.
OA: Blade [value:bladeNumber] over temperature...state is CRITICAL.
OA: Blade [value:bladeNumber] over temperature...state is DEGRADED.
OA: Blade [value:bladeNumber] PCI device missing...state is CRITICAL.
OA: Blade [value:bladeNumber] PCI device missing...state is CRITICAL.
OA: Blade [value:bladeNumber] PCI device missing...state is DEGRADED.
OA: Blade [value:bladeNumber] PCI device missing...state is DEGRADED.
OA: Blade [value:bladeNumber] Power Control fault...state is CRITICAL.
OA: Blade [value:bladeNumber] Power Control fault...state is DEGRADED.
OA: Blade [value:bladeNumber] properly partners with its neighbor.
OA: Blade [value:bladeNumber] reported an unusually high power allocation value. Please see customer advisory c01668472. Its invalid power value of [value]W has been capped at [value]W.
OA: Blade [value:bladeNumber] requested too little power.
OA: Blade [value:bladeNumber] Storage Condition fault...state is CRITICAL.
OA: Blade [value:bladeNumber] Storage Condition fault...state is DEGRADED.
OA: Blade [value:bladeNumber] thermal state is CRITICAL.
OA: Blade [value:bladeNumber] thermal state is DEGRADED.
OA: Blade in bay #[value:bladeNumber] status changed from [OK/Degraded/Failed] to [OK/Degraded/Failed]
OA: Blade in bay #[value:bladeNumber] status changed to [OK/Degraded/Failed]
OA: Blade removed from bay [value:bladeNumber]
OA: Blade removed from bay [value:bladeNumber]
OA: DC Subsystem Overload - FAILED. Redundant Power: [value]W DC, Present Power [value]W AC.
OA: Ekeying: Partner device of blade [value:bladeNumber] was removed, no more mezzanine card required on blade [value:bladeNumber].
OA: Fan Removed: Bay #[value:fanNumber]
OA: Fan Status Changed: Bay #[value:fanNumber] From: [degraded/failed/ok] To: [degraded/failed/ok]
OA: Fan Subsystem Status Changed: From: [degraded/failed/ok] To: [degraded/failed/ok]
OA: Hewlett Packard Enterprise strongly recommends replacing power supply #[value] at the customer's earliest possible convenience pursuant to Customer Advisory c01519680.
OA: Internal communication problem detected.
OA: Internal communications restored.
OA: Internal health status of interconnect in bay [value:slotNumber] changed to Degraded
OA: Internal health status of interconnect in bay [value:slotNumber] changed to Failed
OA: Internal health status of interconnect in bay [value:slotNumber] changed to Unknown
OA: Management Processor on Blade [value:bladeNumber] appears unresponsive.
OA: Mixing different fan models is not supported. The fan in bay #[value:fanNumber] must be replaced with the proper part number.
OA: Mixing different power supply models is not supported. The power supply in bay #[value] must be replaced with the proper part number.
OA: Power Supplies Connected To Both AC and DC Input Lines: Unsupported Configuration.
OA: Power Supplies Not Connected To Identical Capacity Input Lines.
OA: PS Removed: Bay #[value]
OA: PS Status Changed: Bay #[value] From: [unknown/ok/degraded/failed] To: [unknown/ok/degraded/failed]
OA: PS Status Changed: Bay #[value] From: [unknown/ok/degraded/failed] To: [unknown/ok/degraded/failed] - due to communication issues. Reinserting Power Supplies may correct the issue.
OA: PS Subsystem N + 1 Redundancy - FAILED.
OA: PS Subsystem N + 1 Redundancy - REPAIRED.
OA: PS Subsystem N + N Redundancy - FAILED.
OA: PS Subsystem Overload - FAILED.
OA: PS Subsystem Overload – REPAIRED.
OA: PS Subsystem Power Limit - FAILED.
OA: PS Subsystem Power Limit – REPAIRED.
OA: Redundant Onboard Administrator was removed
OA: Required fan is missing from fan bay [value]
OA: The fan in bay #[value:fanNumber] is not supported in this enclosure. Please replace this fan with the proper part number.
OA: The power management controller firmware on blade [value:bladeNumber] must be upgraded. Please see customer advisory c01668472.
OA: TRAY microcode update failed
Log type: LOG_NOTICE, Failure type: SW
OA: Blade [value:bladeNumber] and its partner device need be powered up in a different order.
OA: Blade [value:bladeNumber] cannot be managed as part of the Enclosure Dynamic Power Cap. The blade's iLO firmware version is [value:version] and version [value:version] is required.
OA: Blade [value:bladeNumber] cannot be powered on at this time due to location rules.
OA: Blade [value:bladeNumber] has been allocated a default power value of [value]W because iLO appears unresponsive.
OA: Blade [value:bladeNumber] is missing a Scalable Blade Link.
OA: Blade [value:bladeNumber] is not configured for Virtual Connect Manager.
OA: Blade [value:bladeNumber] requires a proper mezzanine card to partner.
OA: Blade [value:bladeNumber] requires partner in bay [value:bladeNumber] to be powered on first.
OA: Blade [value:bladeNumber]: SMBIOS data carries more than [value] CPU records which cannot be processed with this OA firmware version.
OA: Blade [value:bladeNumber]: SMBIOS data carries more than [value] DIMM records which cannot be processed with this OA firmware version.
OA: Blade [value:bladeNumber]: SMBIOS data carries more than [value] NIC records which cannot be processed with this OA firmware version.
OA: Blade [value:bladeNumber]: SMBIOS data requires [value] DIMM records. [value] are supported by this OA firmware version.
OA: Enclosure Dynamic Power Cap: Device tray firmware doesn't meet minimum required version.
OA: Enclosure Dynamic Power Cap: Server Power Reduction is not enabled; enclosure cap is not guaranteed if power redundancy is lost.
OA: Fan Inserted: Bay #[value:fanNumber]
OA: iLO in bay [value:bladeNumber] appears responsive to the Enclosure Dynamic Power Cap again.
OA: iLO in bay [value:bladeNumber] is not responding to capping requests from the Enclosure Dynamic Power Cap. Reset the iLO.
OA: Server Power Reduction - Deactivated
OA: Tray Update: Can't get TRAY PS microcode version
OA: Warning: integrated device on bus 0x[value] at address 0x[value] has not responded
Log type: LOG_NOTICE, Failure type: Info
OA: AC Subsystem Overloaded - REPAIRED
OA: Blade [value:bladeNumber] Ambient Temperature Cable state is OK.
OA: Blade [value:bladeNumber] Ambient Temperature Sensor state is OK.
OA: Blade [value:bladeNumber] Ambient Temperature state is OK.
OA: Blade [value:bladeNumber] cannot be managed as part of the Enclosure Dynamic Power Cap. The blade is not a supported model.
OA: Blade [value:bladeNumber] cannot be managed as part of the Enclosure Dynamic Power Cap. The blade reports that it is not capable of dynamic power capping.
OA: Blade [value:bladeNumber] cannot be managed as part of the Enclosure Dynamic Power Cap. The blade does not have the required iLO license.
OA: Blade [value:bladeNumber] complies with location rules now.
OA: Blade [value:bladeNumber] Disk Tray is Open state is OK.
OA: Blade [value:bladeNumber] firmware management completed.
OA: Blade [value:bladeNumber] firmware management started.
OA: Blade [value:bladeNumber] found a partner device.
OA: Blade [value:bladeNumber] FRU memory state is OK.
OA: Blade [value:bladeNumber] has been allocated [value] watts but iLO is reporting the blade is powered off.
OA: Blade [value:bladeNumber] has been denied power but iLO is reporting the blade is powered on.
OA: Blade [value:bladeNumber] Internal Temperature Sensor state is OK.
OA: Blade [value:bladeNumber] Internal Temperature state is OK.
OA: Blade [value:bladeNumber] is now configured for Virtual Connect Manager.
OA: Blade [value:bladeNumber] is properly cooled.
OA: Blade [value:bladeNumber] is reporting nominal health status.
OA: Blade [value:bladeNumber] Main Logic Board state is OK.
OA: Blade [value:bladeNumber] over temperature state is OK.
OA: Blade [value:bladeNumber] PCI device state is OK.
OA: Blade [value:bladeNumber] PCI device state is OK.
OA: Blade [value:bladeNumber] Power Control state is OK.
OA: Blade [value:bladeNumber] Storage Condition state is OK.
OA: Blade [value:bladeNumber] thermal state is OK.
OA: Blade inserted in bay [value:bladeNumber]
OA: DC Subsystem Overloaded - REPAIRED
OA: Enclosure ID setting has been restored to factory defaults
OA: Fan Inserted: Bay #[value:fanNumber]
OA: Internal health status of interconnect in bay [value:slotNumber] changed to OK
OA: IO module in slot [value:slotNumber] temperature is normal
OA: Management Process on Blade [value:bladeNumber] appears responsive again.
OA: Midplane replacement detected. Serial number changed from [value] to [value].
OA: Mixing 400Hz PSs with other PSs is not supported
OA: Power Limit Set To: [value]
OA: Power Limit Set To: Not Set
OA: Power Subsystem Redundancy Mode Set To: [N+N/N+1/N+0/]
OA: Power Supplies Connected To Both AC and DC Input Lines: REPAIRED
OA: PS Inserted: Bay #[value]
OA: PS Subsystem N + 1 Redundancy - REPAIRED
OA: PS Subsystem N + 1 Redundancy Power Limit - REPAIRED
OA: PS Subsystem N + N Redundancy - REPAIRED
OA: PS Subsystem N + N Redundancy Power Limit - REPAIRED
OA: PS Subsystem Overloaded - REPAIRED
OA: PS Subsystem Power Limit - REPAIRED
OA: Redundant Onboard Administrator was inserted
OA: Server Power Reduction - Activated
OA: Server Power Reduction Mode - Disabled
OA: Server Power Reduction Mode - Enabled
OA: Server Power Reduction Mode - Enabled
OA: TRAY microcode updated from UNKNOWN version to version [value:version]
OA: TRAY microcode updated from version [value:version] to version [value:version]
Log type: LOG_INFO, Failure type: HW
OA: Interconnect removed from bay [value:slotNumber]
Log type: LOG_INFO, Failure type: SW
OA: A USB Key was inserted into the Onboard Administrator.
OA: A USB Key was removed from the Onboard Administrator.
OA: A CD-ROM Drive was inserted into the Onboard Administrator.
OA: Media was removed from CD-ROM Drive.
OA: CD-ROM Drive has no media.
OA: Media in CD-ROM Drive detected. Volume Label: [value]
OA: Blade [value:bladeNumber]: Mezz card internal data problem for [value].
OA: Failed to mount [CD/DVD/USB Key]: [value:errorCode]
OA: Failed to mount [CD/DVD/USB Key][value]: unsupported filesystem.
OA: Interconnect inserted in bay [value:slotNumber]
OA: VC module in interconnect bay [value:slotNumber] has firmware revision [value:version] but minimum firmware revision [value:version] is required
Log type: LOG_INFO, Failure type: Info
OA Tray firmware upgrade initiated.
OA Tray firmware upgrade succeeded.
OA: Blade [value:bladeNumber] management processor firmware upgrade initiated.
OA: Blade [value:bladeNumber] management processor firmware upgrade succeeded.
OA: Fan [value] firmware upgrade initiated.
OA: Fan [value] firmware upgrade succeeded.
OA: Interconnect [value:slotNumber] firmware upgrade initiated.
OA: Interconnect [value:slotNumber] firmware upgrade succeeded.
OA: Interconnect [value] firmware upgrade initiated.
OA: Interconnect [value] firmware upgrade succeeded.
OA: Interconnect module in bay [value:slotNumber] was powered off
OA: Interconnect module in bay [value:slotNumber] was powered on
OA: LCD firmware upgrade initiated.
OA: LCD firmware upgrade succeeded.
OA: Server Blade in bay [value:bladeNumber] has been powered down
OA: Server blade in bay [value:bladeNumber] has been powered on