Management log messages

Log type: LOG_EMERG, Failure type: SW

OA: Internal System Firmware Error, Rebooting.

Log type: LOG_WARNING, Failure type: HW

OA: A port mismatch was found with server blade bay [value:bladeNumber] and interconnect bay [value:slotNumber]

OA: Temperature of I/O module in slot [value:slotNumber] is at alert level

Log type: LOG_WARNING, Failure type: SW

OA: iLO in bay [value] has not responded to the previous [value:count] capping requests from the Enclosure Dynamic Power Cap.

Log type: LOG_CRIT, Failure type: HW

OA Tray firmware upgrade failed.

OA: Blade in bay [value:bladeNumber] contains an unsupported #[value] mezz card.

OA: Enclosure Status changed from [N/A/Unknown/OK/Degraded/Failed] to [N/A/Unknown/OK/Degraded/Failed].

OA: Failed to initialize key components. Please call support immediately.

OA: Fan [value] firmware upgrade failed.

OA: Interconnect [value:slotNumber] firmware upgrade failed.

OA: Interconnect [value] firmware upgrade failed.

OA: LCD fails to respond to keystrokes.

OA: LCD firmware upgrade failed.

OA: LCD not functioning properly, pausing operation for 10 seconds.

OA: LCD Status is: Failed

OA: mgmt: GPIO initialization failed.

OA: mgmt: i2c initialization failed.

OA: Mismatching I/O was detected on Blade [value:bladeNumber], interconnect [value].

OA: Mismatching I/O was detected on Blade [value:bladeNumber], Mezzanine Card [value], Port [value].

OA: Mismatching I/O was detected on Interconnect [value], Port [value].

OA: Temperature of I/O module in slot [value:slotNumber] is critical - module shut down

OA: Unsupported Device in bay #[value:bladeNumber].

OA: Unsupported IO Module in bay #[value:slotNumber].

OA: Unsupported IO Module location in bay #[value:slotNumber].

Log type: LOG_CRIT, Failure type: SW

OA: Blade [value:bladeNumber] management processor firmware upgrade failed.

OA: Error reading Fru Board Info for the LCD.

OA: Error reading Fru information for the LCD.

OA: Error reading Fru Internal Use Area for the LCD.

OA: mgmt: Failed to acquire enclosure semaphore.

Log type: LOG_CRIT, Failure type: Info

OA: Mismatching I/O condition resolved, Blade [value:bladeNumber], interconnect [value] was removed.

OA: Mismatching I/O was removed on Blade [value:bladeNumber], Mezzanine Card [value], Port [value].

OA: Mismatching I/O was removed on Interconnect [value], Port [value].

Log type: LOG_NOTICE, Failure type: HW

OA: AC Subsystem Overload - FAILED. Redundant Power: [value]W DC, Present Power [value]W AC.

OA: Blade [value:bladeNumber] Ambient Temperature Cable fault...state is CRITICAL.

OA: Blade [value:bladeNumber] Ambient Temperature Cable fault...state is DEGRADED.

OA: Blade [value:bladeNumber] Ambient Temperature caution...state is CRITICAL.

OA: Blade [value:bladeNumber] Ambient Temperature caution...state is DEGRADED.

OA: Blade [value:bladeNumber] Ambient Temperature Sensor fault...state is CRITICAL.

OA: Blade [value:bladeNumber] Ambient Temperature Sensor fault...state is DEGRADED.

OA: Blade [value:bladeNumber] cannot partner with its neighbor.

OA: Blade [value:bladeNumber] Disk Tray is Open...state is CRITICAL.

OA: Blade [value:bladeNumber] Disk Tray is Open...state is DEGRADED.

OA: Blade [value:bladeNumber] FRU memory fault...state is CRITICAL.

OA: Blade [value:bladeNumber] FRU memory fault...state is DEGRADED.

OA: Blade [value:bladeNumber] has integrated blade cross connection, Mezzanine card [value] is superfluous.

OA: Blade [value:bladeNumber] Internal Temperature caution...state is CRITICAL.

OA: Blade [value:bladeNumber] Internal Temperature caution...state is DEGRADED.

OA: Blade [value:bladeNumber] Internal Temperature Sensor fault...state is CRITICAL.

OA: Blade [value:bladeNumber] Internal Temperature Sensor fault...state is DEGRADED.

OA: Blade [value:bladeNumber] is not properly cooled.

OA: Blade [value:bladeNumber] is not supported.

OA: Blade [value:bladeNumber] is reporting degraded health status.

OA: Blade [value:bladeNumber] is reporting failed health status.

OA: Blade [value:bladeNumber] Main Logic Board fault...state is CRITICAL.

OA: Blade [value:bladeNumber] Main Logic Board fault...state is DEGRADED.

OA: Blade [value:bladeNumber] needs a partner device.

OA: Blade [value:bladeNumber] over temperature...state is CRITICAL.

OA: Blade [value:bladeNumber] over temperature...state is DEGRADED.

OA: Blade [value:bladeNumber] PCI device missing...state is CRITICAL.

OA: Blade [value:bladeNumber] PCI device missing...state is CRITICAL.

OA: Blade [value:bladeNumber] PCI device missing...state is DEGRADED.

OA: Blade [value:bladeNumber] PCI device missing...state is DEGRADED.

OA: Blade [value:bladeNumber] Power Control fault...state is CRITICAL.

OA: Blade [value:bladeNumber] Power Control fault...state is DEGRADED.

OA: Blade [value:bladeNumber] properly partners with its neighbor.

OA: Blade [value:bladeNumber] reported an unusually high power allocation value. Please see customer advisory c01668472. Its invalid power value of [value]W has been capped at [value]W.

OA: Blade [value:bladeNumber] requested too little power.

OA: Blade [value:bladeNumber] Storage Condition fault...state is CRITICAL.

OA: Blade [value:bladeNumber] Storage Condition fault...state is DEGRADED.

OA: Blade [value:bladeNumber] thermal state is CRITICAL.

OA: Blade [value:bladeNumber] thermal state is DEGRADED.

OA: Blade in bay #[value:bladeNumber] status changed from [OK/Degraded/Failed] to [OK/Degraded/Failed]

OA: Blade in bay #[value:bladeNumber] status changed to [OK/Degraded/Failed]

OA: Blade removed from bay [value:bladeNumber]

OA: Blade removed from bay [value:bladeNumber]

OA: DC Subsystem Overload - FAILED. Redundant Power: [value]W DC, Present Power [value]W AC.

OA: Ekeying: Partner device of blade [value:bladeNumber] was removed, no more mezzanine card required on blade [value:bladeNumber].

OA: Fan Removed: Bay #[value:fanNumber]

OA: Fan Status Changed: Bay #[value:fanNumber] From: [degraded/failed/ok] To: [degraded/failed/ok]

OA: Fan Subsystem Status Changed: From: [degraded/failed/ok] To: [degraded/failed/ok]

OA: Hewlett Packard Enterprise strongly recommends replacing power supply #[value] at the customer's earliest possible convenience pursuant to Customer Advisory c01519680.

OA: Internal communication problem detected.

OA: Internal communications restored.

OA: Internal health status of interconnect in bay [value:slotNumber] changed to Degraded

OA: Internal health status of interconnect in bay [value:slotNumber] changed to Failed

OA: Internal health status of interconnect in bay [value:slotNumber] changed to Unknown

OA: Management Processor on Blade [value:bladeNumber] appears unresponsive.

OA: Mixing different fan models is not supported. The fan in bay #[value:fanNumber] must be replaced with the proper part number.

OA: Mixing different power supply models is not supported. The power supply in bay #[value] must be replaced with the proper part number.

OA: Power Supplies Connected To Both AC and DC Input Lines: Unsupported Configuration.

OA: Power Supplies Not Connected To Identical Capacity Input Lines.

OA: PS Removed: Bay #[value]

OA: PS Status Changed: Bay #[value] From: [unknown/ok/degraded/failed] To: [unknown/ok/degraded/failed]

OA: PS Status Changed: Bay #[value] From: [unknown/ok/degraded/failed] To: [unknown/ok/degraded/failed] - due to communication issues. Reinserting Power Supplies may correct the issue.

OA: PS Subsystem N + 1 Redundancy - FAILED.

OA: PS Subsystem N + 1 Redundancy - REPAIRED.

OA: PS Subsystem N + N Redundancy - FAILED.

OA: PS Subsystem Overload - FAILED.

OA: PS Subsystem Overload – REPAIRED.

OA: PS Subsystem Power Limit - FAILED.

OA: PS Subsystem Power Limit – REPAIRED.

OA: Redundant Onboard Administrator was removed

OA: Required fan is missing from fan bay [value]

OA: The fan in bay #[value:fanNumber] is not supported in this enclosure. Please replace this fan with the proper part number.

OA: The power management controller firmware on blade [value:bladeNumber] must be upgraded. Please see customer advisory c01668472.

OA: TRAY microcode update failed

Log type: LOG_NOTICE, Failure type: SW

OA: Blade [value:bladeNumber] and its partner device need be powered up in a different order.

OA: Blade [value:bladeNumber] cannot be managed as part of the Enclosure Dynamic Power Cap. The blade's iLO firmware version is [value:version] and version [value:version] is required.

OA: Blade [value:bladeNumber] cannot be powered on at this time due to location rules.

OA: Blade [value:bladeNumber] has been allocated a default power value of [value]W because iLO appears unresponsive.

OA: Blade [value:bladeNumber] is missing a Scalable Blade Link.

OA: Blade [value:bladeNumber] is not configured for Virtual Connect Manager.

OA: Blade [value:bladeNumber] requires a proper mezzanine card to partner.

OA: Blade [value:bladeNumber] requires partner in bay [value:bladeNumber] to be powered on first.

OA: Blade [value:bladeNumber]: SMBIOS data carries more than [value] CPU records which cannot be processed with this OA firmware version.

OA: Blade [value:bladeNumber]: SMBIOS data carries more than [value] DIMM records which cannot be processed with this OA firmware version.

OA: Blade [value:bladeNumber]: SMBIOS data carries more than [value] NIC records which cannot be processed with this OA firmware version.

OA: Blade [value:bladeNumber]: SMBIOS data requires [value] DIMM records. [value] are supported by this OA firmware version.

OA: Enclosure Dynamic Power Cap: Device tray firmware doesn't meet minimum required version.

OA: Enclosure Dynamic Power Cap: Server Power Reduction is not enabled; enclosure cap is not guaranteed if power redundancy is lost.

OA: Fan Inserted: Bay #[value:fanNumber]

OA: iLO in bay [value:bladeNumber] appears responsive to the Enclosure Dynamic Power Cap again.

OA: iLO in bay [value:bladeNumber] is not responding to capping requests from the Enclosure Dynamic Power Cap. Reset the iLO.

OA: Server Power Reduction - Deactivated

OA: Tray Update: Can't get TRAY PS microcode version

OA: Warning: integrated device on bus 0x[value] at address 0x[value] has not responded

Log type: LOG_NOTICE, Failure type: Info

OA: AC Subsystem Overloaded - REPAIRED

OA: Blade [value:bladeNumber] Ambient Temperature Cable state is OK.

OA: Blade [value:bladeNumber] Ambient Temperature Sensor state is OK.

OA: Blade [value:bladeNumber] Ambient Temperature state is OK.

OA: Blade [value:bladeNumber] cannot be managed as part of the Enclosure Dynamic Power Cap. The blade is not a supported model.

OA: Blade [value:bladeNumber] cannot be managed as part of the Enclosure Dynamic Power Cap. The blade reports that it is not capable of dynamic power capping.

OA: Blade [value:bladeNumber] cannot be managed as part of the Enclosure Dynamic Power Cap. The blade does not have the required iLO license.

OA: Blade [value:bladeNumber] complies with location rules now.

OA: Blade [value:bladeNumber] Disk Tray is Open state is OK.

OA: Blade [value:bladeNumber] firmware management completed.

OA: Blade [value:bladeNumber] firmware management started.

OA: Blade [value:bladeNumber] found a partner device.

OA: Blade [value:bladeNumber] FRU memory state is OK.

OA: Blade [value:bladeNumber] has been allocated [value] watts but iLO is reporting the blade is powered off.

OA: Blade [value:bladeNumber] has been denied power but iLO is reporting the blade is powered on.

OA: Blade [value:bladeNumber] Internal Temperature Sensor state is OK.

OA: Blade [value:bladeNumber] Internal Temperature state is OK.

OA: Blade [value:bladeNumber] is now configured for Virtual Connect Manager.

OA: Blade [value:bladeNumber] is properly cooled.

OA: Blade [value:bladeNumber] is reporting nominal health status.

OA: Blade [value:bladeNumber] Main Logic Board state is OK.

OA: Blade [value:bladeNumber] over temperature state is OK.

OA: Blade [value:bladeNumber] PCI device state is OK.

OA: Blade [value:bladeNumber] PCI device state is OK.

OA: Blade [value:bladeNumber] Power Control state is OK.

OA: Blade [value:bladeNumber] Storage Condition state is OK.

OA: Blade [value:bladeNumber] thermal state is OK.

OA: Blade inserted in bay [value:bladeNumber]

OA: DC Subsystem Overloaded - REPAIRED

OA: Enclosure ID setting has been restored to factory defaults

OA: Fan Inserted: Bay #[value:fanNumber]

OA: Internal health status of interconnect in bay [value:slotNumber] changed to OK

OA: IO module in slot [value:slotNumber] temperature is normal

OA: Management Process on Blade [value:bladeNumber] appears responsive again.

OA: Midplane replacement detected. Serial number changed from [value] to [value].

OA: Mixing 400Hz PSs with other PSs is not supported

OA: Power Limit Set To: [value]

OA: Power Limit Set To: Not Set

OA: Power Subsystem Redundancy Mode Set To: [N+N/N+1/N+0/]

OA: Power Supplies Connected To Both AC and DC Input Lines: REPAIRED

OA: PS Inserted: Bay #[value]

OA: PS Subsystem N + 1 Redundancy - REPAIRED

OA: PS Subsystem N + 1 Redundancy Power Limit - REPAIRED

OA: PS Subsystem N + N Redundancy - REPAIRED

OA: PS Subsystem N + N Redundancy Power Limit - REPAIRED

OA: PS Subsystem Overloaded - REPAIRED

OA: PS Subsystem Power Limit - REPAIRED

OA: Redundant Onboard Administrator was inserted

OA: Server Power Reduction - Activated

OA: Server Power Reduction Mode - Disabled

OA: Server Power Reduction Mode - Enabled

OA: Server Power Reduction Mode - Enabled

OA: TRAY microcode updated from UNKNOWN version to version [value:version]

OA: TRAY microcode updated from version [value:version] to version [value:version]

Log type: LOG_INFO, Failure type: HW

OA: Interconnect removed from bay [value:slotNumber]

Log type: LOG_INFO, Failure type: SW

OA: A USB Key was inserted into the Onboard Administrator.

OA: A USB Key was removed from the Onboard Administrator.

OA: A CD-ROM Drive was inserted into the Onboard Administrator.

OA: Media was removed from CD-ROM Drive.

OA: CD-ROM Drive has no media.

OA: Media in CD-ROM Drive detected. Volume Label: [value]

OA: Blade [value:bladeNumber]: Mezz card internal data problem for [value].

OA: Failed to mount [CD/DVD/USB Key]: [value:errorCode]

OA: Failed to mount [CD/DVD/USB Key][value]: unsupported filesystem.

OA: Interconnect inserted in bay [value:slotNumber]

OA: VC module in interconnect bay [value:slotNumber] has firmware revision [value:version] but minimum firmware revision [value:version] is required

Log type: LOG_INFO, Failure type: Info

OA Tray firmware upgrade initiated.

OA Tray firmware upgrade succeeded.

OA: Blade [value:bladeNumber] management processor firmware upgrade initiated.

OA: Blade [value:bladeNumber] management processor firmware upgrade succeeded.

OA: Fan [value] firmware upgrade initiated.

OA: Fan [value] firmware upgrade succeeded.

OA: Interconnect [value:slotNumber] firmware upgrade initiated.

OA: Interconnect [value:slotNumber] firmware upgrade succeeded.

OA: Interconnect [value] firmware upgrade initiated.

OA: Interconnect [value] firmware upgrade succeeded.

OA: Interconnect module in bay [value:slotNumber] was powered off

OA: Interconnect module in bay [value:slotNumber] was powered on

OA: LCD firmware upgrade initiated.

OA: LCD firmware upgrade succeeded.

OA: Server Blade in bay [value:bladeNumber] has been powered down

OA: Server blade in bay [value:bladeNumber] has been powered on