Message identifiers 24600-24624

Message ID: 24600

Severity: Error

Log message: Logical drive <logical drive number> of array controller <controller name / slot information> has encountered a status change from:

Status: <previous status>

to

Status: <current status>

<previous status> and <current status> values:

  • OK
  • FAILED
  • NOT CONFIGURED
  • INTERIM RECOVERY MODE
  • READY FOR RECOVERY
  • RECOVERING
  • WRONG PHYSICAL DRIVE REPLACED
  • PHYSICAL DRIVE NOT PROPERLY CONNECTED
  • HARDWARE IS OVERHEATING
  • HARDWARE HAS OVERHEATED
  • EXPANDING
  • NOT YET AVAILABLE
  • QUEUED FOR EXPANSION
  • DISABLED DUE TO SCSI ID CONFLICT
  • EJECTED
  • ERASING
  • UNKNOWN

Message ID: 24601

Severity: Informational

Log message: Logical drive <logical drive number> configured on array controller <controller name / slot information> is in a failed state but has had one or more drive replacements and is now ready to change to a status of "OK". However, this status change will not occur until the logical drive is re-enabled. Please re-enable the logical drive either via the Array Configuration Utility or by rebooting the system.

Message ID: 24602

Severity: Warning

Log message: The recovery of logical drive <logical driver number> configured on array controller <controller name / slot information> was aborted while rebuilding due to an unrecoverable read error. Physical drive number <physical drive number> was the replacement drive being rebuilt before the read error occurred, while physical drive number <physical drive number> is the error drive which reported the read error.

Message ID: 24603

Severity: Warning

Log message: Due to an unrecoverable read error, the recovery of logical drive %3 configured on array controller <controller name / slot information> was aborted while rebuilding a physical drive.

The physical drive which was being rebuilt is located in bay <bay number> of box <box number> which is connected to port <port number> of array controller <controller name / slot information>.

The physical drive that reported the read error is located in bay <bay number> of box <box number> which is connected to port <port number> of array controller <controller name / slot information>.

Message ID: 24604

Severity: Warning

Log message: The recovery of logical drive <logical drive number> configured on array controller <controller name / slot information> was aborted while rebuilding due to an unrecoverable write error. Physical drive number <physical drive number> was the replacement drive being rebuilt before the write error occurred, while physical drive number <physical drive number> is the error drive which reported the write error.

Message ID: 24605

Severity: Warning

Log message: Due to an unrecoverable write error, the recovery of logical drive <logical drive number> configured on array controller <controller name / slot information> was aborted while rebuilding a physical drive.

The physical drive which was being rebuilt is located in bay <bay number> of box <box number> which is connected to port <port number> of array controller <controller name / slot information>.

The physical drive that reported the write error is located in bay <bay number> of box <box number> which is connected to port <port number> of array controller <controller name / slot information>.

Message ID: 24606

Severity: Error

Log message: Logical drive <logical drive number> configured on array controller <controller name / slot information> returned a fatal error during a read/write request from/to the volume.

Logical block address <lba number>, block count <bc number> and command <command number> were taken from the failed logical I/O request.

Array controller <controller name / slot information> is also reporting that the last physical drive to report a fatal error condition (associated with this logical request), is located on bus <bus number> and ID <ID number>.

Message ID: 24607

Severity: Warning

Log message: The event information received from array controller <controller name / slot information> was of an unknown or unrecognized class.

An excerpt of the controller message is as follows: <message from firmware>.

Message ID: 24608

Severity: Informational

Log message: Array controller <controller name / slot information> has reported that storage box number <box number> was added to port <port number>. This connection is through I/O module number <module number> on the storage box.

Message ID: 24609

Severity: Error

Log message: Array controller <controller name / slot information> has reported that storage box number <box number> was removed from port <port number>. This connection was through I/O module number <module number> on the storage box. This event can occur when either a sole I/O module or data cable is removed.

Message ID: 24610

Severity: Warning

Log message: Array controller <controller name / slot information> has reported that either redundant I/O module number <module number> in box <box number> was removed or the cable to this module was removed. The cable and I/O module were connected to port <port number> of the array controller.

Message ID: 24611

Severity: Informational

Log message: Array controller <controller name / slot information> has reported that either redundant I/O module number <module number> in box <box number> was added or the cable to this module was connected. The cable and I/O module are connected to port <port number> of the array controller.

Message ID: 24612

Severity: Informational

Log message: Array controller <controller name / slot information> has reported that box <box number> connected to port <port number> is now marked as repaired (re-added after a previous failure).

Message ID: 24613

Severity: Informational

Log message: Array controller <controller name / slot information> has reported that either redundant I/O module number <module number> in box <box number> was repaired or its path was repaired. Box <box number> is connected to port <port number> of the array controller.

Message ID: 24614

Severity: Informational

Log message: Array controller <controller name / slot information> has reported that the external array controller attached to port <port number> has been disconnected or powered down.

Message ID: 24615

Severity: Informational

Log message: Array controller <controller name / slot information> has reported that an external array controller was attached to port <port number> or was previously attached and was powered on.

Message ID: 24616

Severity: Warning

Log message: Array controller <controller name / slot information> is reporting that an unsupported configuration has occurred with the redundant cabling that is attached between port <port number> and box <box number>. <firmware information>. Please check the cabling and ensure that a supported configuration is being used.

<firmware information> values:

  • The Smart Array firmware is reporting that no additional details are available
  • The Smart Array firmware is reporting that the redundant cabling configuration on the controller has a mix of storage boxes with and without redundant I/O modules
  • The Smart Array firmware is reporting that a redundant I/O paths exist due to direct loopback of the controller ports
  • The Smart Array firmware is reporting that the redundant I/O modules of this box are not cabled for good fault tolerance
  • The Smart Array firmware is reporting that the redundant I/O modules of this box have multiple paths to the controller

Message ID: 24617

Severity: Warning

Log message: Array controller <controller name / slot information> is reporting that an unsupported configuration has occurred with the redundant cabling that is attached to port <port number>. <firmware information>. Please check the cabling and ensure that a supported configuration is being used.

<firmware information> values:

  • The Smart Array firmware is reporting that no additional details are available”
  • The Smart Array firmware is reporting that the redundant cabling configuration on the controller has a mix of storage boxes with and without redundant I/O modules
  • The Smart Array firmware is reporting that a redundant I/O paths exist due to direct loopback of the controller ports
  • The Smart Array firmware is reporting that the redundant I/O modules of this box are not cabled for good fault tolerance
  • The Smart Array firmware is reporting that the redundant I/O modules of this box have multiple paths to the controller

Message ID: 24618

Severity: Warning

Log message: Array controller <controller name / slot information> is reporting that an unsupported configuration has occurred with the redundant cabling that is attached to port <port number>. Please check the cabling and ensure that a supported configuration is being used.

Message ID: 24619

Severity: Informational

Log message: Fan number <fan number> in box <box number> was <inserted / removed>. Box <box number> is attached to port <port number> of array controller <controller name / slot information>.

Message ID: 24620

Severity: Informational

Log message: Fan number <fan number> located on fan module <fan module number> in box <box number> was <inserted / removed>. Box <box number> is attached to port <port number> of array controller <controller name / slot information>.

Message ID: 24621

Severity: Error

Log message: Fan number <fan number> is reporting a failure. This fan is located in box number <box number> which is connected to port <port number> of array controller <controller name / slot information>. The controller may attempt to shut down the power to the storage device and/or spin down the installed disk drive(s).

Message ID: 24622

Severity: Error

Log message: Fan number <fan number> located on fan module <fan module number> is reporting a failure. This fan is located in box number <box number> which is connected to port <port number> of array controller <controller name / slot information>. The controller may attempt to shut down the power to the storage device and/or spin down the installed disk drive(s).

Message ID: 24623

Severity: Informational

Log message: Fan number <fan number> is reporting a degraded condition. This fan is located in box number <box number> which is connected to port <port number> of array controller <controller name / slot information>.

Message ID: 24624

Severity: Informational

Log message: Fan number <fan number> located on fan module <fan module number> is reporting a degraded condition. This fan is located in box number <box number> which is connected to port <port number> of array controller <controller name / slot information>.