1732-Slot # Drive Array – Cache Module Battery Pack Missing

Symptom

1732-Slot # Drive Array – Cache Module Battery Pack Missing. Posted-Write Cache is disabled until additional battery packs are installed.

Cause
  • The battery pack has not been installed.

  • The battery pack is degraded or has failed.

Action
  1. Be sure that the battery is connected and functioning.

    For more information, see "HPE Smart Storage Battery issues flowchart" in the HPE ProLiant Gen9 Troubleshooting Guide, Volume I on the Hewlett Packard Enterprise website.

  2. Replace the HPE Smart Storage battery.

    For more information, see the server maintenance and service guide on the Hewlett Packard Enterprise website.