1830-Slot X Drive Array – Incorrect cache module power source detected

Symptom

1830-Slot X Drive Array – Incorrect cache module power source detected. Caching will be enabled when Cache Module Battery Pack is installed and charged. Action: Remove the Super-cap. Install a Battery Pack.

Cause

An FBWC capacitor pack was installed.

Action
  1. Remove the FBWC capacitor pack.
  2. Install an HPE Smart Storage Battery.

    For more information, see the server user guide on the Hewlett Packard Enterprise website.