1703-Slot X Drive Array controller - Memory Self-Test Error

Symptom

1703-Slot X Drive Array controller - Memory Self-Test Error. Access to all storage has been disabled. Action: Replace Flash Backed Write Cache module. If error persists, replace controller.

Cause
  • The cache module or controller is experiencing a fault

  • The cache module or controller has failed.

Action
  1. Replace the cache module.
  2. If the issue persists, replace the controller.
    For removal and replacement procedures, see the server maintenance and service guide on the Hewlett Packard Enterprise website.