Message identifiers 24800-24808
Message ID: 24800
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> is reporting that the%3physical drive located in bay <bay number> could not be authenticated as a genuine HPE hard drive. This drive's status LEDs will not be controlled.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message ID: 24801
Severity: Informational
Log message: Array controller <controller name / slot information> has reported that its cache is missing. This is an unsupported configuration.
Message ID: 24802
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> is reporting that its cache is missing. This is an unsupported configuration.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message ID: 24803
Severity: Warning
Log message: Array controller <controller name / slot information> has reported that it previously locked up with code <lockup code>.
Message ID: 24804
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that it previously locked up with code <lockup code>.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message ID: 24805
Severity: Warning
Log message: Array controller <controller name / slot information> has reported that Supercap is enabled but the cache module flash memory is missing. This is an unsupported configuration.
Message ID: 24806
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that Supercap is enabled but the cache module flash memory is missing. This is an unsupported configuration.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.
Message ID: 24807
Severity: Warning
Log message: Array controller <controller name / slot information> has reported that the cache module flash memory is installed but Supercap is disabled. This is an unsupported configuration.
Message ID: 24808
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled as <chassis label> has reported that the cache module flash memory is installed but Supercap is disabled. This is an unsupported configuration.
The external Smart Array controller is attached to the host side Smart Array controller <controller name / slot information>.