Enclosure-Link log messages
Log type: LOG_WARNING, Failure type: SW
OA: Enclosure Link Daemon could not register for events.
Log type: LOG_CRIT, Failure type: SW
Enclosure-Link: Could not acquire bottom enclosure's UUID. Cannot set RUID.
Enclosure-Link: Failed to read topology
Enclosure-Link: Got unexpected error from socket: [value]
Enclosure-Link: RUID recovered: [value]
Log type: LOG_ERR, Failure type: SW
Enclosure-Link: [value] enclosure(s) seen on Enclosure Link. Only [value:Max_Enclosures] enclosure(s) supported. Please remove [value] enclosure(s)
Enclosure-Link: Corrupted topology on eth2
Enclosure-Link: Corrupted topology on eth3
Enclosure-Link: Failed to create socket
Enclosure-Link: Failed to detect Enclosure topology
Enclosure-Link: Failed to disable lower chain
Enclosure-Link: Failed to disable upper chain
Enclosure-Link: Failed to enable lower chain
Enclosure-Link: Failed to enable upper chain
Enclosure-Link: Failed to generate EVENT for initial topology detection
Enclosure-Link: Failed to generate EVENT for topology change
Enclosure-Link: Failed to get local address. Will keep retrying
Enclosure-Link: Failed to log into enclosure [value:IpAddress]
Enclosure-Link: Failed to probe newly attached/detached device
Enclosure-Link: Failed to read events from chain
Enclosure-Link: Failed to register with enclosure [value:IpAddress]
Enclosure-Link: Failed to retrieve enclosure addresses from lower elink chain
Enclosure-Link: Failed to retrieve enclosure addresses from upper elink chain
Enclosure-Link: Failed to send ICMP packet to host
Enclosure-Link: Failed to update hosts file
Enclosure-Link: Failed to write updated topology map
Enclosure-Link: Found 2 GuestPCs on Enclosure Link. This setup is not supported.
Enclosure-Link: Ignoring invalid Enclosure Link address
Enclosure-Link: Seeing heavy traffic on Enclosure Link chain. This may affect topology.
Enclosure-Link: This can also occur if the enclosures have been connected in a loop which is an unsupported configuration. Please make sure the top and bottom enclosures are not connected to each other.
Log type: LOG_INFO, Failure type: Info
Enclosure-Link: Calling getEvent
Enclosure-Link: Device attached on lower interface
Enclosure-Link: Device attached on upper interface
Enclosure-Link: Device attached/detached but no topology changes detected
Enclosure-Link: Device detached on lower interface
Enclosure-Link: Device detached on upper interface
Enclosure-Link: Doing elink topology scan now
Enclosure-Link: Found new elink topology. Notifying subsystems
Enclosure-Link: Found new Topology: [value] enclosure added to chain ([value] total)
Enclosure-Link: Found new Topology: [value] enclosure removed from chain ([value] total)
Enclosure-Link: Found new Topology: New enclosure connected ([value] total)
Enclosure-Link: Got new TOPOLOGY event on enclosure [value:IpAddress]
Enclosure-Link: Initial topology scan completed successfully
Enclosure-Link: Service started