Redundancy log messages

Log type: LOG_WARNING, Failure type: SW

Redundancy: Active Onboard Administrator has lost link connectivity on the external NIC for [value] seconds. Forcing take over

Redundancy: Failed to read event from mgmt subsystem

Redundancy: Onboard Administrator is switching to Active mode

Redundancy: Onboard Administrator is switching to Standby mode. This OA will now reboot

Log type: LOG_CRIT, Failure type: HW

Redundancy: Onboard Administrator redundancy failed to initialize properly. Try rebooting the Onboard Administrator by reseating the OA module in its bay. If the problem persists, please contact Hewlett Packard Enterprise support.

Log type: LOG_CRIT, Failure type: SW

Redundancy: Caught Signal SIGSEGV

Redundancy: redund: Failed to startup threads

Log type: LOG_ERR, Failure type: HW

Redundancy: Failed automatic Onboard Administrator failover as a result of network link loss on the Active OA board

Log type: LOG_ERR, Failure type: SW

Redundancy: Couldn't get random seed

Redundancy: Error communicating via ethernet with the other Onboard Administrator (heartbeat).

Redundancy: Error communicating via ethernet with the other Onboard Administrator (timeout).

Redundancy: Error communicating with the other Onboard Administrator.

Redundancy: Failed to get enclosure network

Redundancy: Failed to read OA bay number

Redundancy: Failed to read OA status

Redundancy: Other ([Standby/Active]) OA firmware: v[value:version] - This OA ([Standby/Active]) firmware: v[value:version]

Redundancy: Please upgrade to the latest firmware using [this/the other] Onboard Administrator which is the active

Redundancy: WARNING: The other OA ([Standby/Active]) is running a different firmware. OA Redundancy will be degraded

Log type: LOG_NOTICE, Failure type: SW

Redundancy: Assuming active Onboard Administrator network settings.

Redundancy: Enclosure IP mode was [disabled/enabled]

Log type: LOG_INFO, Failure type: SW

Redundancy: Enclosure IP mode configurations have been reset.

Redundancy: Onboard Administrator has now completed the Standby to Active transition

Redundancy: Onboard Administrator redundancy restored.

Redundancy: Service started ([ACTIVE/STANDBY])