Redundancy log messages
Log type: LOG_WARNING, Failure type: SW
Redundancy: Active Onboard Administrator has lost link connectivity on the external NIC for [value] seconds. Forcing take over
Redundancy: Failed to read event from mgmt subsystem
Redundancy: Onboard Administrator is switching to Active mode
Redundancy: Onboard Administrator is switching to Standby mode. This OA will now reboot
Log type: LOG_CRIT, Failure type: HW
Redundancy: Onboard Administrator redundancy failed to initialize properly. Try rebooting the Onboard Administrator by reseating the OA module in its bay. If the problem persists, please contact Hewlett Packard Enterprise support.
Log type: LOG_CRIT, Failure type: SW
Redundancy: Caught Signal SIGSEGV
Redundancy: redund: Failed to startup threads
Log type: LOG_ERR, Failure type: HW
Redundancy: Failed automatic Onboard Administrator failover as a result of network link loss on the Active OA board
Log type: LOG_ERR, Failure type: SW
Redundancy: Couldn't get random seed
Redundancy: Error communicating via ethernet with the other Onboard Administrator (heartbeat).
Redundancy: Error communicating via ethernet with the other Onboard Administrator (timeout).
Redundancy: Error communicating with the other Onboard Administrator.
Redundancy: Failed to get enclosure network
Redundancy: Failed to read OA bay number
Redundancy: Failed to read OA status
Redundancy: Other ([Standby/Active]) OA firmware: v[value:version] - This OA ([Standby/Active]) firmware: v[value:version]
Redundancy: Please upgrade to the latest firmware using [this/the other] Onboard Administrator which is the active
Redundancy: WARNING: The other OA ([Standby/Active]) is running a different firmware. OA Redundancy will be degraded
Log type: LOG_NOTICE, Failure type: SW
Redundancy: Assuming active Onboard Administrator network settings.
Redundancy: Enclosure IP mode was [disabled/enabled]
Log type: LOG_INFO, Failure type: SW
Redundancy: Enclosure IP mode configurations have been reset.
Redundancy: Onboard Administrator has now completed the Standby to Active transition
Redundancy: Onboard Administrator redundancy restored.
Redundancy: Service started ([ACTIVE/STANDBY])