1764-Slot X Drive Array – Capacity Expansion Process is Temporarily Disabled

Symptom

1764-Slot X Drive Array – Capacity Expansion Process is Temporarily Disabled (followed by one of the following:)

  • Expansion will resume when Cache Module has been reattached.
  • Expansion will resume when Cache Module has been replaced.
  • Expansion will resume when Cache Module RAM allocation is successful.
  • Expansion will resume when Cache Module battery/capacitor reaches full charge.
  • Expansion will resume when Automatic Data Recovery has been Completed.
  • Expansion will resume when Cache Module battery/capacitor is connected.
Cause
  • The cache module has been detached.
  • The cache module has been replaced.
  • The cache module RAM allocation was unsuccessful.
  • The HPE Smart Storage Battery is not fully charged.
  • Automatic Data Recovery has not yet completed.
  • The HPE Smart Storage Battery is disconnected.
Action
Follow the action that is displayed onscreen to resume the capacity expansion process.