Event Identifiers 1200-1294

NT Event ID: 1200 (Hex)0x843504b0 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Logical Drive Status Change.

Log Message: Logical drive number %5 on the array controller in %4 has a new status of %2.

SNMP Trap: cpqDa6LogDrvStatusChange - 3034 in CPQIDA.MIB

Symptom: Logical Drive Status Change. This trap indicates that the agent has detected a change in the status of a drive array logical drive. The variable cpqDaLogDrvStatus indicates the current logical drive status.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaLogDrvCntlrIndex
  • cpqDaLogDrvIndex
  • cpqDaLogDrvStatus

Supporting SNMP Trap Description: “Status is now [cpqDaLogDrvStatus].”

NT Event ID: 1201 (Hex)0x843504b1 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Spare Drive Status Change.

Log Message: The spare drive in %4, port %5, bay %6 has a new status of %2.

SNMP Trap: cpqDa6SpareStatusChange - 3035 in CPQIDA.MIB

Symptom: Spare Drive Status Change. This trap indicates that the agent has detected a change in the status of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive status.

User Action: If the spare drive status is failed, replace the drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaSpareCntlrIndex
  • cpqDaSparePhyDrvIndex
  • cpqDaSpareStatus
  • cpqDaSpareBusNumber
  • cpqDaSpareBay

Supporting SNMP Trap Description: “Spare Status is now [cpqDaSpareStatus].”

NT Event ID: 1202 (Hex)0x843504b2 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Physical Drive Status Change.

Log Message: The physical drive in %4, port %5, bay %6 with serial number “%7”, has a new status of %2.

SNMP Trap: cpqDa6PhyDrvStatusChange - 3036 in CPQIDA.MIB

Symptom: Physical Drive Status Change. This trap indicates that the agent has detected a change in the status of a drive array physical drive. The variable cpaDaPhyDrvStatus indicates the current physical drive status.

User Action: If the physical drive status is failed(3) or predictive Failure(4), replace the drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaPhyDrvIndex
  • cpqDaPhyDrvBusNumber
  • cpqDaPhyDrvBay
  • cpqDaPhyDrvModel
  • cpqDaPhyDrvFWRev
  • cpqDaPhyDrvSerialNum
  • cpqDaPhyDrvFailureCode
  • cpqDaPhyDrvStatus

Supporting SNMP Trap Description: “Physical Drive Status is now [cpqDaPhyDrvStatus].”

NT Event ID: 1203 (Hex)0x843504b3 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Physical Drive Threshold Exceeded.

Log Message: The physical drive in %4, port %5, bay %6 with serial number “%7”, has exceeded a drive threshold.

SNMP Trap: cpqDa6PhyDrvThreshPassedTrap - 3037 in CPQIDA.MIB

Symptom: Physical Drive Threshold Passed. This trap indicates that the agent has detected a factory threshold associated with one of the physical drive objects on a drive array has been exceeded.

User Action: Replace the physical drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaPhyDrvCntlrIndex
  • cpqDaPhyDrvIndex
  • cpqDaPhyDrvBusNumber
  • cpqDaPhyDrvBay
  • cpqDaPhyDrvModel
  • cpqDaPhyDrvFWRev
  • cpqDaPhyDrvSerialNum

Supporting SNMP Trap Description: “Factory threshold passed for a physical drive.”

NT Event ID: 1204 (Hex)0x843504b4 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Accelerator Status Change.

Log Message: The array accelerator board attached to the array controller in %4 has a new status of %2.

SNMP Trap: cpqDa6AccelStatusChange - 3038 in CPQIDA.MIB

Symptom: Accelerator Board Status Change. This trap indicates that the agent has detected a change in the status of an array accelerator cache board. The current status is represented by the variable cpqDaAccelStatus.

User Action: If the accelerator board status is permDisabled(5), you may need to replace the accelerator board.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaCntlrModel
  • cpqDaAccelCntlrIndex
  • cpqDaAccelSerialNumber
  • cpqDaAccelTotalMemory
  • cpqDaAccelStatus
  • cpqDaAccelErrCode

Supporting SNMP Trap Description: “Status is now [cpqDaAccelStatus].”

NT Event ID: 1205 (Hex)0x843504b5 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Accelerator Bad Data.

Log Message: The array accelerator board attached to the array controller in %4 is reporting that it contains bad cached data.

SNMP Trap: cpqDa6AccelBadDataTrap - 3039 in CPQIDA.MIB

Symptom: Accelerator Board Bad Data. This trap indicates that the agent has detected an array accelerator cache board that has lost battery power. If data was being stored in the accelerator cache memory when the server lost power, that data has been lost.

User Action: Verify that no data has been lost.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaCntlrModel
  • cpqDaAccelCntlrIndex
  • cpqDaAccelSerialNumber
  • cpqDaAccelTotalMemory

Supporting SNMP Trap Description: “Accelerator lost battery power. Data Loss possible.”

NT Event ID: 1206 (Hex)0x843504b6 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Accelerator Battery Failed.

Log Message: The array accelerator board attached to the array controller in %4 is reporting a battery failure.

SNMP Trap: cpqDa6AccelBatteryFailed - 3040 in CPQIDA.MIB

Symptom: Accelerator Board Battery Failed. This trap indicates that the agent has detected a battery failure associated with the array accelerator cache board.

User Action: Replace the Accelerator Cache Board.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaPhyDrvCntlrIndex
  • cpqDaCntlrHwLocation
  • cpqDaCntlrModel
  • cpqDaAccelCntlrIndex
  • cpqDaAccelSerialNumber
  • cpqDaAccelTotalMemory

Supporting SNMP Trap Description: “Battery status is failed.”

NT Event ID: 1207 (Hex)0x843504b7 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Tape Library Status Change.

Log Message: The tape library in %4, SCSI bus %5, SCSI target %6 has a new status of %7.

SNMP Trap: cpqDa6TapeLibraryStatusChange - 3041 in CPQIDA.MIB

Symptom: Tape Library Status Change. This trap indicates that the agent has detected a change in the status of a tape library. The variable cpqDaTapeLibraryStatus indicates the current tape library status. The variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library.

User Action: If the tape library is failed, check the tape library front panel.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaTapeLibraryCntlrIndex
  • cpqDaTapeLibraryScsiBus
  • cpqDaTapeLibraryScsiTarget
  • cpqDaTapeLibraryScsiLun
  • cpqDaTapeLibraryModel
  • cpqDaTapeLibraryFWRev
  • cpqDaTapeLibrarySerialNumber
  • cpqDaTapeLibraryStatus

Supporting SNMP Trap Description: “Status is now [cpqDaTapeLibraryStatus] for the tape library.”

NT Event ID: 1208 (Hex)0x843504b8 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Tape Library Door Status Change.

Log Message: The tape library in %4, SCSI bus %5, SCSI target %6 has a new door status of %7.

SNMP Trap: cpqDa6TapeLibraryDoorStatusChange - 3042 in CPQIDA.MIB

Symptom: Tape Library Door Status Change. This trap indicates that the agent has detected a change in the door status of a tape library. The variable cpqDaTapeLibraryDoorStatus indicates the current tape library door status. The variable cpqDaTapeLibraryScsiTarget indicates the SCSI ID of the tape library.

User Action: If the tape library door is open, close the tape library door.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaTapeLibraryCntlrIndex
  • cpqDaTapeLibraryScsiBus
  • cpqDaTapeLibraryScsiTarget
  • cpqDaTapeLibraryScsiLun
  • cpqDaTapeLibraryModel
  • cpqDaTapeLibraryFWRev
  • cpqDaTapeLibrarySerialNumber
  • cpqDaTapeLibraryDoorStatus

Supporting SNMP Trap Description: “The door is [cpqDaTapeLibraryDoorStatus] for tape library.”

NT Event ID: 1209 (Hex)0x843504b9 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Tape Drive Status Change.

Log Message: The tape drive in %4, SCSI bus %5, SCSI target %6 has a new status of %7.

SNMP Trap: cpqDa6TapeDriveStatusChange - 3043 in CPQIDA.MIB

Symptom: Tape Drive Status Change. This trap indicates that the agent has detected a change in the status of a tape drive. The variable cpqDaTapeDrvStatus indicates the current tape status. The variable cpqDaTapeDrvScsiIdIndex indicates the SCSI ID of the tape drive.

User Action: If the tape is failed, check the tape and all SCSI connections.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaTapeDrvCntlrIndex
  • cpqDaTapeDrvBusIndex
  • cpqDaTapeDrvScsiIdIndex
  • cpqDaTapeDrvLunIndex
  • cpqDaTapeDrvName
  • cpqDaTapeDrvFwRev
  • cpqDaTapeDrvSerialNumber
  • cpqDaTapeDrvStatus

Supporting SNMP Trap Description: “Status is now [cpqDaTapeDrvStatus] for a tape drive.”

NT Event ID: 1210 (Hex)0x843504ba (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Tape Drive Cleaning Required.

Log Message: The tape drive in %4, SCSI bus %5, SCSI target %6 requires cleaning.

SNMP Trap: cpqDa6TapeDriveCleaningRequired - 3044 in CPQIDA.MIB

Symptom: Tape Drive Cleaning Required trap. The agent has detected a tape drive that needs to have a cleaning tape inserted and run. This causes the tape drive heads to be cleaned.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaTapeDrvCntlrIndex
  • cpqDaTapeDrvBusIndex
  • cpqDaTapeDrvScsiIdIndex
  • cpqDaTapeDrvLunIndex
  • cpqDaTapeDrvName
  • cpqDaTapeDrvFwRev
  • cpqDaTapeDrvSerialNumber

Supporting SNMP Trap Description: “Cleaning is needed for the tape drive.”

NT Event ID: 1211 (Hex)0x843504bb (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Tape Drive Replace Cleaning Tape.

Log Message: The cleaning tape in the tape drive in %4, SCSI bus %5, SCSI target %6 needs to be replaced.

SNMP Trap: cpqDa6TapeDriveCleanTapeReplace - 3045 in CPQIDA.MIB

Symptom: Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new cleaning tape.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaTapeDrvCntlrIndex
  • cpqDaTapeDrvBusIndex
  • cpqDaTapeDrvScsiIdIndex
  • cpqDaTapeDrvLunIndex
  • cpqDaTapeDrvName
  • cpqDaTapeDrvFwRev
  • cpqDaTapeDrvSerialNumber

Supporting SNMP Trap Description: “Cleaning tape needs replacing.”

NT Event ID: 1212 (Hex)0x843504bc (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Fan Status Change.

Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in %4 has a new status of %2.

SNMP Trap: cpqSs5FanStatusChange - 8026 in CPQSTSYS.MIB

Symptom: Storage System fan status change. The agent has detected a change in the Fan Status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status.

User Action: If the fan status is degraded or failed, replace any failed fans.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsBoxCntlrHwLocation
  • cpqSsBoxCntlrIndex
  • cpqSsBoxBusIndex
  • cpqSsBoxVendor
  • cpqSsBoxModel
  • cpqSsBoxSerialNumber
  • cpqSsBoxFanStatus

Supporting SNMP Trap Description: “Storage System fan status changed to [cpqSsBoxFanStatus].”

NT Event ID: 1213 (Hex)0x843504bd (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Temperature Status Change.

Log Message: The %6 %7 storage system connected to SCSI bus %5 of the controller in %4 has a new temperature status of %2.

SNMP Trap: cpqSs5TempStatusChange - 8027 in CPQSTSYS.MIB

Symptom: Storage System Temperature Status Change. The agent has detected a change in the temperature status of a storage system. The variable cpqSsBoxTempStatus indicates the current temperature status.

User Action: If the temperature status is degraded or failed, shut down the storage system as soon as possible. Be sure that the storage system environment is being cooled properly and that no components are overheated.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsBoxCntlrHwLocation
  • cpqSsBoxCntlrIndex
  • cpqSsBoxBusIndex
  • cpqSsBoxVendor
  • cpqSsBoxModel
  • cpqSsBoxSerialNumber
  • cpqSsBoxTempStatus

Supporting SNMP Trap Description: “Storage System temperature status changed to [cpqSsBoxTempStatus].”

NT Event ID: 1214 (Hex)0x843504be (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Fault Tolerant Power Supply Status Change.

Log Message: The fault tolerant power supply in the %6 %7 storage system connected to SCSI bus %5 of the controller in %4 has a new status of %2.

SNMP Trap: cpqSs5PwrSupplyStatusChange - 8028 in CPQSTSYS.MIB

Symptom: Storage System Fault Tolerant Power Supply Status Change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBoxFltTolPwrSupplyStatus indicates the current power supply status.

User Action: If the power supply status is degraded, restore power or replace the failed power supply.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsBoxCntlrHwLocation
  • cpqSsBoxCntlrIndex
  • cpqSsBoxBusIndex
  • cpqSsBoxVendor
  • cpqSsBoxModel
  • cpqSsBoxSerialNumber
  • cpqSsBoxFltTolPwrSupplyStatus

Supporting SNMP Trap Description: “Storage system power supply status changed to [cpqSsBoxFltTolPwrSupplyStatus].”

NT Event ID: 1215 (Hex)0x843504bf (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Fibre Channel Controller Status Change.

Log Message: The Fibre Channel Controller in %4 has a new status of %5.

SNMP Trap: cpqFca3HostCntlrStatusChange - 16028 in CPQFCA.MIB

Symptom: Fibre Channel Host Controller Status Change. This trap indicates that the agent has detected a change in the status of a Fibre Channel Host Controller. The variable cpqFcaHostCntlrStatus indicates the current controller status.

User Action: If the controller status is failed, replace the controller.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqFcaHostCntlrHwLocation
  • cpqFcaHostCntlrIndex
  • cpqFcaHostCntlrStatus
  • cpqFcaHostCntlrModel
  • cpqFcaHostCntlrSerialNumber
  • cpqFcaHostCntlrWorldWideName
  • cpqFcaHostCntlrWorldWidePortName

Supporting SNMP Trap Description: “Host controller has a new status of [cpqFcaHostCntlrStatus].”

NT Event ID: 1216 (Hex)0x843504c0 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Physical Drive Status Change.

Log Message: The physical drive in %4, %5 with serial number “%7”, has a new status of %2.

SNMP Trap: cpqDa7PhyDrvStatusChange - 3046 in CPQIDA.MIB

Symptom: Physical Drive Status Change. This trap indicates that the agent has detected a change in the status of a drive array physical drive. The variable cpqDaPhyDrvStatus indicates the current physical drive status.

User Action: If the physical drive status is failed(3), predictiveFailure(4), ssdWearOut(8) or notAuthenticated(9) replace the drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaPhyDrvCntlrIndex
  • cpqDaPhyDrvIndex
  • cpqDaPhyDrvLocationString
  • cpqDaPhyDrvType
  • cpqDaPhyDrvModel
  • cpqDaPhyDrvFWRev
  • cpqDaPhyDrvSerialNum
  • cpqDaPhyDrvFailureCode
  • cpqDaPhyDrvStatus
  • cpqDaPhyDrvBusNumber

Supporting SNMP Trap Description: “Physical Drive Status is now [cpqDaPhyDrvStatus].”

NT Event ID: 1217 (Hex)0x843504c1 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Spare Drive Status Change.

Log Message: The spare drive in %4, %5 has a new status of %2.

SNMP Trap: cpqDa7SpareStatusChange - 3047 in CPQIDA.MIB

Symptom: Spare Drive Status Change. This trap indicates that the agent has detected a change in the status of a drive array spare drive. The variable cpqDaSpareStatus indicates the current spare drive status.

User Action: If the spare drive status is failed, replace the drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaSpareCntlrIndex
  • cpqDaSparePhyDrvIndex
  • cpqDaSpareStatus
  • cpqDaSpareLocationString
  • cpqDaSpareDrvBusNumber

Supporting SNMP Trap Description: “Spare Status is now [cpqDaSpareStatus].”

NT Event ID: 1218 (Hex)0x843504c2 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Fan Status Change.

Log Message: The %6 %7 storage system connected to %5 of the controller in%4 has a new status of %2.

SNMP Trap: cpqSs6FanStatusChange - 8029 in CPQSTSYS.MIB

Symptom: Storage System Fan Status Change. The agent has detected a change in the fan status of a storage system. The variable cpqSsBoxFanStatus indicates the current fan status.

User Action: If the fan status is degraded or failed, replace any failed fans.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsBoxCntlrHwLocation
  • cpqSsBoxCntlrIndex
  • cpqSsBoxBusIndex
  • cpqSsBoxVendor
  • cpqSsBoxModel
  • cpqSsBoxSerialNumber
  • cpqSsBoxFanStatus
  • cpqSsBoxLocationString

Supporting SNMP Trap Description: “Storage System fan status changed to [cpqSsBoxFanStatus].”

NT Event ID: 1219 (Hex)0x843504c3 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Temperature Status Change.

Log Message: The %6 %7 storage system connected to %5 of the controller in%4 has a new temperature status of %2.

SNMP Trap: cpqSs6TempStatusChange - 8030 in CPQSTSYS.MIB

Symptom: Storage System Temperature Status Change. The agent has detected a change in the temperature status of a storage system. The variable cpqSsBoxTempStatus indicates the current temperature status.

User Action: If the temperature status is degraded or failed, shut down the storage system as soon as possible. Be sure that the storage system environment is being cooled properly and that no components are overheated.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsBoxCntlrHwLocation
  • cpqSsBoxCntlrIndex
  • cpqSsBoxBusIndex
  • cpqSsBoxVendor
  • cpqSsBoxModel
  • cpqSsBoxSerialNumber
  • cpqSsBoxTempStatus
  • cpqSsBoxLocationString

Supporting SNMP Trap Description: “Storage System temperature status changed to [cpqSsBoxTempStatus].”

NT Event ID: 1220 (Hex)0x843504c4 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Fault Tolerant Power Supply Status Change.

Log Message: The fault tolerant power supply in the %6 %7 storage system connected to %5 of the controller in%4 has a new status of %2.

SNMP Trap: cpqSs6PwrSupplyStatusChange - 8031 in CPQSTSYS.MIB

Symptom: Storage System Fault Tolerant Power Supply Status Change. The agent has detected a change in the power supply status of a storage system. The variable cpqSsBoxFltTolPwrSupplyStatus indicates the current power supply status.

User Action: If the power supply status is degraded, restore power or replace the failed power supply.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsBoxCntlrHwLocation
  • cpqSsBoxCntlrIndex
  • cpqSsBoxBusIndex
  • cpqSsBoxVendor
  • cpqSsBoxModel
  • cpqSsBoxSerialNumber
  • cpqSsBoxFltTolPwrSupplyStatus
  • cpqSsBoxLocationString

Supporting SNMP Trap Description: “Storage System power supply status changed to [cpqSsBoxFltTolPwrSupplyStatus].”

NT Event ID: 1221 (Hex)0x843504c5 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: SAS/SATA Physical Drive Status Change.

Log Message: The physical drive in %4, %5 with serial number “%6”, has a new status of %7.

SNMP Trap: cpqSasPhyDrvStatusChange - 5022 in CPQSCSI.MIB

Symptom: Physical Drive Status Change. The Storage Agent has detected a change in the status of a SAS or SATA physical drive. The current physical drive status is indicated in the cpqSasPhyDrvStatus variable.

User Action: If the physical drive status is predictiveFailure(3), failed(5), ssdWearOut(10) or notAuthenticated(12) replace the drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSasHbaHwLocation
  • cpqSasPhyDrvLocationString
  • cpqSasPhyDrvHbaIndex
  • cpqSasPhyDrvIndex
  • cpqSasPhyDrvStatus
  • cpqSasPhyDrvType
  • cpqSasPhyDrvModel
  • cpqSasPhyDrvFWRev
  • cpqSasPhyDrvSerialNumber
  • cpqSasPhyDrvSasAddress

Supporting SNMP Trap Description: “Status is now [cpqSasPhyDrvStatus].”

NT Event ID: 1222 (Hex)0x843504c6 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: SAS/SATA Logical Drive Status Change.

Log Message: Logical drive number %5 on the HBA in %4 has a new status of %6.

SNMP Trap: cpqSasLogDrvStatusChange - 5023 in CPQSCSI.MIB

Symptom: Logical Drive Status Change. The Storage Agent has detected a change in the status of a SAS or SATA logical drive. The current logical drive status is indicated in the cpqSasLogDrvStatus variable.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSasHbaHwLocation
  • cpqSasLogDrvHbaIndex
  • cpqSasLogDrvIndex
  • cpqSasLogDrvStatus
  • cpqSasLogDrvOsName

Supporting SNMP Trap Description: “Status is now [cpqSasLogDrvStatus].”

NT Event ID: 1223 (Hex)0x843504c7 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: SAS Tape Drive Status Change.

Log Message: The tape drive in %4, %5 with serial number "%6", has a new status of %7. (Tape Drive status values: 1=other, 2=ok, 3=offline)

SNMP Trap: cpqSas2TapeDrvStatusChange - 5025 in CPQSCSI.MIB

Symptom: The Storage Agent has detected a change in the status of a SAS tape drive. The current tape drive status is indicated in the cpqSasTapeDrvStatus variable.

Supporting SNMP Trap Data

  • sysName
  • cpqHoTrapFlags
  • cpqSasHbaHwLocation
  • cpqSasTapeDrvLocationString
  • cpqSasTapeDrvHbaIndex
  • cpqSasTapeDrvIndex
  • cpqSasTapeDrvName
  • cpqSasTapeDrvFWRev
  • cpqSasTapeDrvSerialNumber
  • cpqSasTapeDrvSasAddress
  • cpqSasTapeDrvStatus

Supporting SNMP Trap Description: "Status is now %d."

NT Event ID: 1224 (Hex)0x843504c8 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Partner Controller Status Change.

Log Message: The Drive Array Controller in %4 has a Drive Array Partner Controller with serial number %5. This Partner Controller has a new status of %2. (Partner Controller status values: 1=other, 2=ok, 3=generalFailure)

SNMP Trap: cpqDaCntlrPartnerStatusChange - 3048 in CPQIDA.MIB

Symptom: The agent has detected a change in the status of a drive array partner controller. The variable cpqDaCntlrPartnerBoardStatus indicates the current partner controller status. The variable cpqDaCntlrSerialNumber indicates the controller’s serial number and cpqDaCntlrPartnerSerialNumber indicates the partner controller’s serial number.

User Action: Check the partner controller for problems. If lost communication with the partner controller is the result of a user initiated action, no remedial action is required.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaCntlrIndex
  • cpqDaCntlrModel
  • cpqDaCntlrSerialNumber
  • cpqDaCntlrPartnerSerialNumber
  • cpqDaCntlrPartnerBoardStatus

Supporting SNMP Trap Description: "Partner controller status is now %d."

NT Event ID: 1225 (Hex)0x843504c9 (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Storage System Connection Status Change.

Log Message: The %7 storage system connected to %5 of the controller in %4 has a new connection status of %6. (Connection status values: 1=other, 2=notSupported, 3=connected, 4=notConnected)

SNMP Trap: cpqSsConnectionStatusChange - 8032 in CPQSTSYS.MIB

Symptom: The agent has detected a change in the connection status of a storage system. The variable cpqSSboxConnectionStatus indicates the current connection status.

User Action: If the connection status is disconnected, take action to restore the connection between the HBA and the storage system.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSsBoxCntlrHwLocation
  • cpqSsBoxCntlrIndex
  • cpqSsBoxBusIndex
  • cpqSsBoxVendor
  • cpqSsBoxModel
  • cpqSsBoxSerialNumber
  • cpqSsBoxConnectionStatus
  • cpqSsBoxLocationString
  • cpqSsBoxTargetSasAddress
  • cpqSsBoxLocalManageIpAddress

Supporting SNMP Trap Description: "Storage system connection status changed to %d."

NT Event ID: 1226 (Hex)0x843504ca (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: SAS/SATA Physical Drive SSD Wear Status Change.

Log Message: The physical drive in %4, %5 with serial number "%6", has a new solid state wear status of %7. (Drive status values: 1=other, 2=ok, 3=fiftySixDayThreshold, 4=fivePercentThreshold, 5=twoPercentThreshold, 6=ssdWearOut)

SNMP Trap: cpqSasPhyDrvSSDWearStatusChange - 5026 in CPQSCSI.MIB

Symptom: The agent has detected a change in the SSD wear status of a SAS or SATA physical drive. The variable cpqSasPhyDrvSSDWearStatus indicates the current SSD wear status.

User Action: If the SSD wear status is ssdWearOut(6), replace the drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqSasHbaHwLocation
  • cpqSasPhyDrvLocationString
  • cpqSasPhyDrvHbaIndex
  • cpqSasPhyDrvIndex
  • cpqSasPhyDrvType
  • cpqSasPhyDrvModel
  • cpqSasPhyDrvFWRev
  • cpqSasPhyDrvSerialNumber
  • cpqSasPhyDrvSasAddress

Supporting SNMP Trap Description: "Solid State Disk Wear Status is now %d."

NT Event ID: 1227 (Hex)0x843504cb (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: Drive Array Physical Drive SSD Wear Status Change.

Log Message: The physical drive in %4, %5 with serial number "%6", has a new solid state wear status of %7. (Drive status values: 1=other, 2=ok, 3=fiftySixDayThreshold, 4=fivePercentThreshold, 5=twoPercentThreshold, 6=ssdWearOut)

SNMP Trap: cpqDaPhyDrvSSDWearStatusChange- 3049 in CPQIDA.MIB

Symptom: This trap signifies that the agent has detected a change in the SSD wear status of a drive array physical drive. The variable cpqDaPhyDrvSSDWearStatus indicates the current SSD wear status.

User Action: If the SSD wear status is ssdWearOut(6), replace the drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqDaCntlrHwLocation
  • cpqDaPhyDrvCntlrIndex
  • cpqDaPhyDrvIndex
  • cpqDaPhyDrvLocationString
  • cpqDaPhyDrvType
  • cpqDaPhyDrvModel
  • cpqDaPhyDrvFWRev
  • cpqDaPhyDrvSerialNum
  • cpqDaPhyDrvSSDWearStatus
  • cpqSasPhyDrvSSDWearStatus

Supporting SNMP Trap Description: "Solid State Disk Wear Status is now %d."

NT Event ID: 1228 (Hex)0x843504cc (cpqstmsg.dll)

Log Severity: Warning (2)

Event Title: IDE Disk SSD Wear Status Change.

Log Message: The ATA disk drive with model %6 and serial number %7 has a new solid state wear status of %2. (SSD wear status values: 1=other, 2=ok, 3=fiftySixDayThreshold, 4=fivePercentThreshold, 5=twoPercentThreshold, 6=ssdWearOut)

SNMP Trap: cpqIdeAtaDiskSSDWearStatusChange - 14006 in CPQIDE.MIB

Symptom: This trap signifies that the agent has detected a change in the SSD wear status of a SATA physical drive. The variable cpqIdeAtaDiskSSDWearStatus indicates the current SSD wear status.

User Action: If the SSD wear status is ssdWearOut(6), replace the drive.

Supporting SNMP Trap Data:

  • sysName
  • cpqHoTrapFlags
  • cpqIdeAtaDiskControllerIndex
  • cpqIdeAtaDiskIndex
  • cpqIdeAtaDiskModel
  • cpqIdeAtaDiskFwRev
  • cpqIdeAtaDiskSerialNumber
  • cpqIdeAtaDiskSSDWearStatus
  • cpqIdeAtaDiskChannel
  • cpqIdeAtaDiskNumber

Supporting SNMP Trap Description: "Solid State Disk Wear Status is now %d."

Event identifier: cpqstmsg.dll - 1280 (Hex)0x84350500 (Service Event)

Log Severity: Warning (2)

Log Message: Unable to allocate memory. This indicates a low memory condition. Rebooting the system will correct this error.

Event identifier: cpqstmsg.dll - 1281 (Hex)0x84350501 (Service Event)

Log Severity: Warning (2)

Log Message: Could not read from the registry subkey. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error.

Event identifier: cpqstmsg.dll - 1282 (Hex)0x84350502 (Service Event)

Log Severity: Warning (2)

Log Message: Could not write the registry subkey: “%1”. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error.

Event identifier: cpqstmsg.dll - 1283 (Hex)0x84350503 (Service Event)

Log Severity: Warning (2)

Log Message: Could not read the registry subkey: “%1”. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error.

Event identifier: cpqstmsg.dll - 1284 (Hex)0x84350504 (Service Event)

Log Severity: Warning (2)

Log Message: Could not write the registry subkey: “%1”. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error.

Event identifier: cpqstmsg.dll - 1285 (Hex)0x84350505 (Service Event)

Log Severity: Warning (2)

Log Message: Could not write the registry subkey: “%1”. This error can be caused by a corrupt registry or a low memory condition. Rebooting the server may correct this error.

Event identifier: cpqstmsg.dll - 1294 (Hex)0x8435050e (Service Event)

Log Severity: Warning (2)

Log Message: Unsupported storage system. The ProLiant storage system %1 is unsupported by this version of the Storage Agents. Upgrade the agents to the latest version.