1700 Series 1700-Slot # Drive Array – Please replace battery 1701-Slot # Drive Array – Please install battery 1702-SCSI Cable Error Detected 1703-Slot X Drive Array controller - Memory Self-Test Error 1704-Slot X System Halted 1705-Slot X Drive Array 1706-The Extended BIOS Data Area in Server Memory has been Overwritten 1707-Slot X Drive Array Controller 1707-Slot X Drive Array Controller 1709-One or more attached hard drives could not be authenticated 1710-Slot X Drive Array – Non-Array Controller Drives Detected 1711-Slot # Drive Array – Stripe size too large 1712-Slot X Drive Array – RAID 5 volume(s) present 1713-Slot X Array Controller – Redundant ROM Reprogramming Failure 1714-Slot X Array Controller – Redundant ROM Checksum Error 1715-Slot # Drive Array Controller – Memory Error(s) Occurred 1716-Slot # Drive Array – Unrecoverable Media Errors Detected on Drives 1717-Slot X Drive Array – Disk Drive(s) Reporting OVERHEATED Condition 1718-Slot X Drive Array – Device discovery found more devices attached 1719-A controller failure event occurred 1720-Slot X Drive Array – S.M.A.R.T. Hard Drive(s) Detect imminent failure 1721-Slot # Drive Array – Drive Parameter Tracking Predicts Imminent Failure 1723-Slot X Drive Array – Improving signal integrity 1724-Slot # Drive Array – Physical Drive Position Change(s) Detected 1726-Slot X Drive Array – Cache Memory Size or Battery Presence Has Changed 1727-Slot X Drive Array – New (or Previously Failed) Logical Drive(s) Attachment Detected 1728-Slot # Drive Array – Abnormal Shut-Down Detected 1729-Slot # Drive Array – Disk Performance Optimization Scan in Progress 1730-Fixed Disk 0 Does Not Support DMA Mode 1731-Fixed Disk 1 Does Not Support DMA Mode 1732-Slot # Drive Array – Cache Module Battery Pack Missing 1733-Slot # Drive Array – Storage Enclosure Firmware Upgrade Problem Detected 1734-Slot # Drive Array – Disk Drive(s) Responding to Incorrect SCSI ID 1735-Slot # Drive Array – Unsupported Redundant Cabling Configuration Detected 1736-Trusted Platform Module Error 1737-Slot X Drive Array – Redundant Cabling Configuration has excess Device Paths 1738-Slot # Drive Array – Storage Enclosure Redundant Cabling Problem Detected 1739-Slot # Drive Array – Redundant Cabling is not as recommended 1740-Fixed Disk 0 failed set Block Mode 1741-Fixed Disk 1 failed set Block Mode 1742-Slot X Drive Array - Previously Ejected Drive(s) Detected 1743-Slot # Drive Array – Logical Drive Erase Operation in Progress 1743-Slot # Drive Array – Logical Drive Erase Operation(s) are Queued 1744-Slot X Drive Array – Drive Erase Operation In Progress 1745-Slot X Drive Array - Drive Erase Operation Completed 1746-Slot X Drive Array – Unsupported Storage Connection Detected 1747-Slot # Drive Array – Unsupported Array Configuration Detected 1748-Slot # Drive Array – Unsupported Cache Module Battery Attached 1749-Slot X Drive Array – Cache Module Flash Memory being erased 1750-Fixed Disk 0 failed ID command 1751-Fixed Disk 1 failed ID command 1752-Slot X Drive Array – Controller not supported in this server model 1753-Slot X Drive Array – Array Controller Maximum Operating Temperature Exceeded 1754-Slot X Drive Array – One or more RAID levels are configured 1762-Slot X Drive Array – Controller Firmware Upgrade Needed 1763-Slot X Drive Array – Cache module is detached 1764-Slot X Drive Array – Capacity Expansion Process is Temporarily Disabled 1766-Slot X Drive Array requires System ROM Upgrade 1768-Slot X Drive Array – Resuming logical drive expansion process 1769-Slot X Drive Array – Drive(s) Disabled 1770-Slot X Drive Array – Disk Drive Firmware Update Recommended 1774-Slot X Drive Array – Obsolete data found in Cache Module 1775-Slot X Drive Array – Storage Enclosure Cabling Problem Detected 1776-Slot X Drive Array – Shared SAS Port Connection Conflict Detected 1777-Slot X Drive Array – Storage Enclosure Problem Detected 1778-Slot X Drive Array resuming Automatic Data Recovery (Rebuild) process 1779-Slot X Drive Array – Logical drive(s) previously failed 1783-Slot X Drive Array Controller Failure 1784-Slot X Drive Array – Logical Drive Failure 1784-Slot X Drive Array – Drive Failure 1785-Slot XX Not Configured 1786-Slot X Drive Array Recovery Needed 1787-Slot X Drive Array Operating in Interim Recovery (Degraded) Mode 1788-Slot X Drive Array Reports Incorrect Drive Replacement 1789-Slot X Drive Array Disk Drive(s) Not Responding 1792-Slot X Drive Array – Valid Data Found in Write-Back Cache 1793-Slot X Drive Array – Data in Cache has been lost 1794-Slot X Drive Array – Cache Module Battery is Charging 1795-Slot X Drive Array – Cache Module Configuration Error 1796-Slot X Drive Array – Flash Backed Write Cache module is not 1797-Slot X Drive Array – Write-Back Cache Backup Previously Failed 1797-Slot X Drive Array – Write-Back Cache Read Error Occurred 1797-Slot X Drive Array – Write-Back Cache Restore Previously Failed 1798-Slot X Drive Array – Cache Module Self-Test Error Occurred 1799-Slot X Drive Array – Drive(s) Disabled due to Cache Data Loss 1799-Slot X Drive Array – Drive(s) Disabled due to Write-Back Cache Data Loss 179A-Slot X Drive Array – Flash Backed Write Cache has been disabled