Message identifiers 24675-24699

Message Id: 24675

Severity: Warning

Log message: Data that was previously consistent is now being reported as inconsistent.<additional data> The inconsistent data may be caused by a power loss during write activity or by a drive returning corrupt data. The inconsistent data is between block address <block address 1> and block address <block address 2> of logical drive <logical drive number>. The inconsistent physical drive can be found in bay <bay number> of box <box number> connected to port <port number> of array controller <controller name / slot information>.

<additional data> values:

  • The parity data does not match the data drives.
  • “”

Message Id: 24676

Severity: Informational

Log message: Surface analysis has repaired an inconsistent stripe on logical drive <logical drive number>. This repair was conducted by overwriting the statistically incorrect stripe on the physical drive found in bay <bay number> of box <box number> connected to port <port number> of array controller <controller name / slot information>.

Message Id: 24677

Severity: Informational

Log message: Surface analysis has repaired an inconsistent stripe on logical drive <logical drive number> connected to array controller <controller name / slot information>. This repair was conducted by updating the parity data to match the data drive contents.

Message Id: 24678

Severity: Warning

Log message: The license key <license key> on array controller <controller name / slot information> is nearing its expiration date. The license key will expire in <number of days> day(s).

Message Id: 24679

Severity: Error

Log message: The license key <license key> on array controller <controller name / slot information> has expired.

Message Id: 24680

Severity: Informational

Log message: The firmware image for Smart Array controller <controller name / slot information> has changed.

The firmware was flashed from:

Revision: <old revision number>

to

Revision: <new revision number>

Message Id: 24681

Severity: Warning

Log message: Device bus fault occurred on storage box <box number>, port <port number> of array controller <controller name / slot information>. This may result in a downshift in transfer rate for one or more hard drives on the bus.

Message Id: 24682

Severity: Informational

Log message: An error log update has occurred for the physical drive with BMIC device index <device index number> of array controller <controller name / slot information>.

Message Id: 24683

Severity: Warning

Log message: Array controller <controller name / slot information> has reported an uncorrectable read error during rebuild operations for logical drive <logical drive number>. The uncorrectable media defects are between logical block address <block address 1> and logical block address <block address 2>. The host will be unable to read some blocks between this address range until the blocks are overwritten. The logical drive rebuild is continuing so that the volume can regain fault tolerance. Capacity expansion operations must be avoided while the affected blocks are unreadable.

Message Id: 24684

Severity: Informational

Log message: The consistency initialization pass has completed for logical drive <logical drive number> of array controller <controller name / slot information>.

Message Id: 24685

Severity: Warning

Log message: Array controller <controller name / slot information> has reported an uncorrectable read error during surface analysis operations for logical drive <logical drive number>. A media error was encountered that is not correctable due to media errors on other physical drive(s) belonging to this logical volume. The uncorrectable media defects are between logical block address <block address 1> and logical block address <block address 2>. The host will be unable to read some blocks between this address range until the blocks are overwritten. Capacity expansion operations must be avoided while the blocks are unreadable.

Message Id: 24686

Severity: Informational

Log message: Array controller <controller name / slot information> has reported that the surface analysis uncorrectable read error condition for logical drive <logical drive number> has ended. The previously reported media defects have been overwritten. Capacity expansion operations may now be conducted.

Message Id: 24687

Severity: Informational

Log message: A firmware update is needed for the physical drive with product ID <ID number> connected to array controller <controller name / slot information>. The recommended minimum firmware revision should be <revision number>.

Message Id: 24688

Severity: Informational

Log message: Power supply number <power supply number> was <inserted / removed>. This power supply is located in box <box number> which is attached to port <port number> of array controller <controller name / slot information>.

Message Id: 24690

Severity: Warning

Log message: A SAS link PHY error has been detected. The PHY error threshold has been exceeded for PHY number <PHY number> located on expander number <expander number>. This expander can be found in box <box number> which is attached to port <port number> of array controller <controller name / slot information>.

Message Id: 24691

Severity: Warning

Log message: A SAS link error has been detected between port <port number> of array controller <controller name / slot information> and I/O module number <module number> located in box number <box number>. Please check this data path and the associated hardware.

Message Id: 24692

Severity: Warning

Log message: A SAS link error has been detected between port <port number> of array controller <controller name / slot information> and <attached device><attached device index>. Please check this data path and the associated hardware.

<attached device> values:

  • an expander
  • another controller
  • a hard drive in bay
  • an unknown internal device

Message Id: 24693

Severity: Warning

Log message: A SAS link error has been detected from the onboard expander of array controller <controller name / slot information>. Please check this controller to ensure it is functioning properly.

Message Id: 24694

Severity: Warning

Log message: A SAS link error has been detected between a Smart Array controller's onboard expander and an externally attached storage box. The error was detected between port <port number> of array controller <controller name / slot information> and I/O module number <module number> located in box number <box number>. Please check this data path and the associated hardware.

Message Id: 24695

Severity: Warning

Log message: A SAS link error has been detected between the onboard expander (port <port number>) of array controller <controller name / slot information> and <attached device><attached device index>. Please check this data path and the associated hardware.

Message Id: 24696

Severity: Warning

Log message: A SAS link error has been detected between I/O module <module number 1> of box <box number 1> and I/O module <module number 2> of box <box number 2>. These boxes are connected to port <port number> of array controller <controller name / slot information>. Please check this data path and the associated hardware.

Message Id: 24697

Severity: Warning

Log message: A SAS link error has been detected in bay <bay number> of box <box number> which is connected to port <port number> of array controller <controller name / slot information>. Please check this data path and the associated hardware.

Message Id: 24698

Severity: Warning

Log message: A SAS link error has been detected between array controller <controller name / slot information> and the switch expander connected to port <port number> of this controller. Please check this data path and the associated hardware.

Message Id: 24699

Severity: Warning

Log message: A SAS link error has been detected between a switch expander and I/O module <module number> of box <box number>. This hardware is connected to port <port number> of controller <controller name / slot information>. Please check this data path and the associated hardware.