1797-Slot X Drive Array Write-Back Cache Backup Previously Failed
Symptom
1797-Slot X Drive Array - Flash Backed Write Cache module read or backup error occurred. Action: Replace Flash Backed Write Cache module.
Cause
- HPE Smart Storage Battery pack was not sufficiently charged to provide backup power for the cache module.
- The data could not be copied to the Write-Back Cache.
- The metadata stored in the Write-Back Cache could not be read or written.
Action
- Use iLO to check the HPE Smart Storage Battery charge. Verify that the battery charge is sufficient to enable caching.
- Be sure the cache module is seated properly.
- Reseat the cache module.
- Replace the cache module.
For more information, see the server maintenance and service guide on the Hewlett Packard Enterprise website.