383-NVDIMM Error

Symptom

383-NVDIMM Error – Proc X, DIMM Y is configured for Cluster On Die (CoD) but system is NOT configured for CoD. All NVDIMMs on Proc X are disabled. Action: Enable CoD or Sanitize all NVDIMMs on Proc X.

Solution 1
Cause

The NVDIMM was previously used in a server that did not have a QPI Snoop Configuration of Cluster on Die. The current server has a different QPI Snoop Configuration setting.

Action
  1. Change the QPI Snoop Configuration setting to Cluster on Die.

    For more information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise website.

Solution 2
Action
  1. Sanitize all NVDIMMs on Processor X.

    For more information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise website.