383-NVDIMM Error
383-NVDIMM Error – Proc X, DIMM Y is configured for Cluster On Die (CoD) but system is NOT configured for CoD. All NVDIMMs on Proc X are disabled. Action: Enable CoD or Sanitize all NVDIMMs on Proc X.
Solution 1 Cause
Action
The NVDIMM was previously used in a server that did not have a QPI Snoop Configuration of Cluster on Die. The current server has a different QPI Snoop Configuration setting.
-
Change the QPI Snoop Configuration setting to Cluster on Die.
For more information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise website.
Solution 2 Action
-
Sanitize all NVDIMMs on Processor X.
For more information, see the HPE 8GB NVDIMM User Guide on the Hewlett Packard Enterprise website.