This appliance, {enclosure name and bay number}, has not discovered the frame that contains it

Symptom

This appliance, {enclosure name and bay number}, has not discovered the frame that contains it. As a result, it may not be able to communicate with other appliances and cannot form an appliance cluster.

ID: HACluster.EnclosureNotDiscovered

Severity: Warning

Health Category: Ha-nodes

Resource URI: /rest/appliance/ha-nodes/{enclosure ID}

Cause

Frame link module discovery has not occurred.

Action
  1. Check the activity on the Settings page to see if hardware discovery is in progress. If so, wait for that process to finish.
  2. If the specified appliance has recently been factory reset, reimaged, or replaced, restore a backup. The backup contains the necessary information to regain control of the frame.
  3. If not restoring from a backup, perform a factory reset of the frame link module before performing the Hardware Setup from the console.