Warning: The system is not configured for redundant power because it has X redundant power delivery device(s) on side A and Y redundant power delivery device(s) on side B

Symptom

Warning: The system is not configured for redundant power because it has X redundant power delivery device(s) on side A and Y redundant power delivery device(s) on side B. The system must have at least Z redundant power delivery device(s) on each side to have redundant power.

ID: ERM.redundancy.ANALYSIS_REDUNDANCY_MESSAGE_POWERPATHAB

Severity: Warning

Health Category: Power

Resource URI: /rest/server-hardware/<id> and /rest/enclosures/<id>

Cause

The current system configuration does not support redundant power.

Action
  1. Do one of the following:
    • Configure the system with the specified number of redundant power delivery devices on side A and side B.
    • Verify that the configuration matches the target system.