1784-Slot X Drive Array – Logical Drive Failure

Symptom

1784-Slot X Drive Array – Logical Drive Failure

Cause
  • A drive is not installed correctly or has failed.
  • A cable is not installed correctly.
Action
  1. Be sure all cables are connected properly and securely.
    For more information, see "Resolving loose connections" in the troubleshooting guide for your product on the Hewlett Packard Enterprise website (http://www.hpe.com/info/enterprise-docs).
  2. Be sure all drives are fully seated.
  3. Determine which drive is defective using HPE SSA.

    For more information, see theHPE Smart Storage Administrator User Guide on the Hewlett Packard Enterprise website.

  4. Replace the defective cables, the defective drive, or both.

    For more information, see the server maintenance and service guide on the Hewlett Packard Enterprise website.