1712-Slot X Drive Array – RAID 5 volume(s) present
1712-Slot X Drive Array – RAID 5 volume(s) present with 56 drives or more, but cache size <= 32MB. This configuration is not recommended. Consider configuring volume(s) to RAID 0 or 1, reducing the number of drives, or upgrading the Array Accelerator module.
Solution 1 Cause
Action
The cache size is smaller than recommended for the current configuration.
-
Migrate logical drives to RAID 0 or 1.
For more information, see the HPE Smart Storage Administrator User Guide on the Hewlett Packard Enterprise website.
Solution 2 Action
-
Reduce the number of drives in the array.
For more information, see the HPE Smart Storage Administrator User Guide on the Hewlett Packard Enterprise website.
Solution 3 Action
-
Upgrade to a larger-sized cache module.
For more information, see the HPE Smart Storage Administrator User Guide on the Hewlett Packard Enterprise website.