1712-Slot X Drive Array – RAID 5 volume(s) present

Symptom

1712-Slot X Drive Array – RAID 5 volume(s) present with 56 drives or more, but cache size <= 32MB. This configuration is not recommended. Consider configuring volume(s) to RAID 0 or 1, reducing the number of drives, or upgrading the Array Accelerator module.

Solution 1
Cause

The cache size is smaller than recommended for the current configuration.

Action
  1. Migrate logical drives to RAID 0 or 1.

    For more information, see the HPE Smart Storage Administrator User Guide on the Hewlett Packard Enterprise website.

Solution 2
Action
  1. Reduce the number of drives in the array.

    For more information, see the HPE Smart Storage Administrator User Guide on the Hewlett Packard Enterprise website.

Solution 3
Action
  1. Upgrade to a larger-sized cache module.

    For more information, see the HPE Smart Storage Administrator User Guide on the Hewlett Packard Enterprise website.