The standby frame link module in bay X contains configuration data which is inconsistent with the active frame link module
The standby frame link module in bay X contains configuration data which is inconsistent with the active frame link module. There is a potential for data loss if this issue is not resolved.
This alert is new in HPE OneView 3.1.
ID: hpris.emRegistry.<version>.EmDataReplicationFault
Severity: Critical
Health Category: Enclosure
Resource URI: /rest/v1/Chassis/1/EnclosureManagerBays/1/
The shared configuration data between the standby and active frame link modules is not successfully replicated on the standby frame link module. Redundant operations may be compromised.
-
Reset the standby frame link module in bay X, or remove and reinstall.
WARNING:
The active frame link module should not be reset while the standby is in this state.
-
If the issue persists, replace the standby frame link module.
For more information, see the frame maintenance and service guide on the Hewlett Packard Enterprise website.