1720-Slot X Drive Array – S.M.A.R.T. Hard Drive(s) Detect imminent failure

Symptom

1720-Slot X Drive Array – S.M.A.R.T. Hard Drive(s) Detect imminent failure: Port X Box Y Bay(s) Z. Do not replace drive unless all other drives in the array are online! Back up data before replacing drive(s) if using RAID 0.

Solution 1
Cause

A hard drive SMART predictive failure condition was detected. The drive might need to be replaced in the future.

Action
  1. If this drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive and restore all data afterward.

    For more information, see the maintenance and service guide for your product on the Hewlett Packard Enterprise website.

Solution 2
Action
  1. If this drive is part of a fault-tolerant configuration, do not replace this drive unless all other drives in the array are online.