The LINK port on the frame link module X is connected to the frame link module Y in enclosure Z that is not managed by this appliance
The LINK port on the frame link module X is connected to the frame link module Y in enclosure Z that is not managed by this appliance. As a result, it is not possible to communicate with the connected frame link module.
ID: hpris.emRegistry.<version>.EmLinkNeighborOwnerMismatch
Severity: Critical
This event is for external link port 23. The port has been properly connect to another frame link port, but both frame link modules have been claimed by a different instance of HPE OneView.
-
Do one of the following:
- If the
frame cabled to frame link module X is cabled in error, disconnect the LINK port from frame link module X, and then connect it to a frame link module in a
frame that is managed by this appliance.
For more information, see the frame setup and installation guide on the Hewlett Packard Enterprise website.
- If the intent is to manage the
frame, you must perform a factory reset on
frame Z before it can be managed by this appliance.
A factory reset will remove all prior configuration from frame Z. For more information, see the frame maintenance and service guide on the Hewlett Packard Enterprise website.