The server hardware in bay X will not be allowed to power on
The server hardware in bay X will not be allowed to power on due to mezzanine card Y not matching the type of interconnect Z.
ID: hpris.emRegistry.<version>.BladeConfigurationFault
Severity: Critical
Health category: ServerBlade
Resource URI: /rest/v1/Chassis/1/BladeBays/1/
At least one interconnect in the frame is not compatible with the mezzanine card(s) within the frame in bay X.
-
If the error occurs on a single
frame, do the following:
-
Remove the
frame in bay X, and then do one of the following:
- Remove mezzanine card Y.
- Move mezzanine card Y to a slot that matches the interconnect type.
- Reinstall the frame in bay X.
-
Remove the
frame in bay X, and then do one of the following:
-
If the error occurs on multiple compute modules, consider moving interconnect Z to a bay with a
server that is compatible with the mezzanine card type.