The server hardware in bay X will not be allowed to power on

Symptom

The server hardware in bay X will not be allowed to power on due to mezzanine card Y not matching the type of interconnect Z.

ID: hpris.emRegistry.<version>.BladeConfigurationFault

Severity: Critical

Health category: ServerBlade

Resource URI: /rest/v1/Chassis/1/BladeBays/1/

Cause

At least one interconnect in the frame is not compatible with the mezzanine card(s) within the frame in bay X.

Action
  • If the error occurs on a single frame, do the following:
    1. Remove the frame in bay X, and then do one of the following:
      • Remove mezzanine card Y.
      • Move mezzanine card Y to a slot that matches the interconnect type.
    2. Reinstall the frame in bay X.
  • If the error occurs on multiple compute modules, consider moving interconnect Z to a bay with a server that is compatible with the mezzanine card type.

    For removal and replacement procedures, see the frame maintenance and service guide in the Hewlett Packard Enterprise Information Library.