Unable to communicate with the drive in drive bay X
Unable to communicate with the drive in drive bay X.
Followed by either:
-
The drive is part of logical JBOD Y.
-
The drive is part of logical JBOD Y and is being used by server profile Z.
ID: HpSmartStorageDiskDrive.MSG.CommunicationFailure
Severity: Critical
Health Category: Drive enclosure
Resource URI: /rest/drive-enclosures/
- Remove and then reinstall the drive in the specified drive bay.
-
If the issue persists, do one of the following:
- Replace the drive.
-
Remove the logical JBOD.
-
Check the drive status and volume integrity by using the Smart Storage Administrator:
- If this drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive, and then restore all data.
- If this drive is part of a fault-tolerant configuration, do not replace this drive unless all other drives in the volume are online.