313-HP Smart Storage Battery X Failure

Symptom

313-HP Smart Storage Battery X Failure – Battery Shutdown Event Code: XXXX. Action: Remove power. If issue persists, update iLO FW. If issue still persists, call HP service.

Cause
  • The HPE Smart Storage battery might lose charge when left shelved for long periods.

  • The HPE Smart Storage battery is degraded or has failed.

  • The iLO firmware is not the latest version.

Action
  1. Remove and then reinstall the server.

    For more information, see the server user guide on the Hewlett Packard Enterprise website.

  2. If the issue persists, update the iLO firmware.

    For more information, see the HPE iLO user guide on the Hewlett Packard Enterprise website.

  3. If the issue persists, contact Hewlett Packard Enterprise support.